HBM FS22 DI Manual de usuario

User Manual
English
FS22 DI
Industrial BraggMETER DI

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
HBM FiberSensing, S.A.
Optical Business
Rua Vasconcelos Costa, 277
4470-640 Maia
Portugal
Tel. +351 229 613 010
Fax +351 229 613 020
www.hbm.com/fs
Mat.: 7-2002.4248
DVS: A4248-6.0 HBM: public
10.2017
Interrogator version: v2.0
SW version: v1.7
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.

FS22 DI A4248-6.0 HBM: public 3
English
1 Technical Details 6.........................................
1.1 General Information 6........................................
1.2 System Components 7.......................................
1.3 Technical Data 8............................................
2 Regulatory and Certification Considerations 10................
2.1 Environment Considerations 10.................................
2.1.1 Disposal of your Old Appliance 10...............................
2.2 Laser Safety 11..............................................
2.2.1 Symbols 11..................................................
2.2.2 Class 1 Laser 11..............................................
2.2.3 General Precautions Considerations 12..........................
2.2.4 Certification 13...............................................
3 Operation 14................................................
3.1 Connectors 14................................................
3.1.1 Standard 14..................................................
3.1.2 Rack-Mountable 15...........................................
3.2 Setting Up 16................................................
3.2.1 Power Supply 16.............................................
3.2.2 Optical Connectors 16.........................................
3.2.3 Ethernet Connection 17........................................
3.3 Switching On 17..............................................
3.4 Switching Off 18..............................................
3.5 Operating the Interrogator 19...................................
3.5.1 Network Properties 19.........................................
3.5.2 Interrogator IP Address 23.....................................
3.5.3 Synchronization 24............................................
3.5.4 Operation 27.................................................
4 Measuring Examples 34......................................
4.1 Typical Configuration 34.......................................

4A4248-6.0 HBM: public FS22 DI
4.1.1 HBM FS Wavelengths 36......................................
4.2 Definitions and Operation Methods 37...........................
4.2.1 Wavelength 37...............................................
4.2.2 Power 38....................................................
4.2.3 Gain 39.....................................................
4.2.4 Threshold 40.................................................
4.3 Common Measuring Difficulties 41..............................
4.3.1 Dirty Connector 41............................................
4.3.2 Broken Connector 43..........................................
4.3.3 Reflective Fiber Ending 43.....................................
4.3.4 Cut Fiber 44.................................................
4.3.5 Fuse Failure 46...............................................
5 Remote Communications 48..................................
5.1 Communication Protocol Syntax 48.............................
5.1.1 Command Syntax 48..........................................
5.1.2 Common Commands 50.......................................
5.1.3 System Commands 51........................................
5.1.4 Acquisition Commands 54.....................................
6 BraggMONITOR DI Software Details 63........................
6.1 Software Version 63...........................................
6.2 Install and Uninstall Software 63................................
6.2.1 System Requirements 63......................................
6.2.2 Software Installation 64........................................
6.2.3 Software Uninstall 65..........................................
6.3 Running the Software 65.......................................
6.3.1 Network Properties 65.........................................
6.3.2 Run as Administrator 66.......................................
7 BraggMONITOR DI User Interface 68..........................
7.1 General Bar 69...............................................
7.1.1 Acquisition 70................................................

FS22 DI A4248-6.0 HBM: public 5
7.1.2 Software and Interrogator Information 75.........................
7.1.3 Exit Application 75............................................
7.2 Graphical Area 75............................................
7.2.1 Graphical View 76............................................
7.2.2 Numerical View 77............................................
7.2.3 Spectral View 78..............................................
7.2.4 FFT View 80.................................................
7.2.5 Configuration 81..............................................
7.2.6 SCPI Interface 89.............................................

Technical Details
6A4248-6.0 HBM: public FS22 DI
1 Technical Details
1.1 General Information
The Industrial BraggMETER DI is a continuous swept
laser scanning interrogator for fiber Bragg grating (FBG)
sensors. It includes a traceable wavelength reference
that provides continuous calibration to ensure system
accuracy over long term operation. The high dynamic
range and high output power allow high resolution to be
attained even for long fiber leads and lossy connections.
Multiple sensors can be connected in series in each opti
cal fiber, which in combination with the eight optical chan
nels with parallel acquisition for the FS22 - Industrial
BraggMETER DI, makes it particularly suitable for large
scale sensing networks, acquiring a large number of sen
sors simultaneously, providing 1000 S/s acquisition rates
with sub picometer resolution.
The BraggMETER is available in Standard and Rack-
mountable format. This Manual applies to the following
equipment:
Standard
K-FS22-01-500-120 FS22 – Industrial BraggMETER DI Single channel
K-FS22-03-500-120 FS22 – Industrial BraggMETER DI Single channel
K-FS22-01-500-420 FS22 – Industrial BraggMETER DI Quad channel
K-FS22-03-500-420 FS22 – Industrial BraggMETER DI Quad channel
K-FS22-01-500-820 FS22 – Industrial BraggMETER DI Octo channel
K-FS22-03-500-820 FS22 – Industrial BraggMETER DI Octo channel

Technical Details
FS22 DI A4248-6.0 HBM: public 7
Rack-Mountable
K-FS22-11-500-120 FS22 – Industrial BraggMETER DI Single channel
K-FS22-13-500-120 FS22 – Industrial BraggMETER DI Single channel
K-FS22-11-500-420 FS22 – Industrial BraggMETER DI Quad channel
K-FS22-13-500-420 FS22 – Industrial BraggMETER DI Quad channel
K-FS22-11-500-820 FS22 – Industrial BraggMETER DI Octo channel
K-FS22-13-500-820 FS22 – Industrial BraggMETER DI Octo channel
HBM FiberSensing interrogators are compatible with
catman® software, a powerful tool for data acquisition
and processing.
1.2 System Components
The Industrial BraggMETER DI set includes:
Standard format Rack-mountable format
- Interrogator
- Power cord
- Power adapter
- Ethernet cable (L ~2 m)
- Mounting blocks with M6 screws
- Connector protection caps
- Quick guide
- Digital support material
- Calibration certificate
- Interrogator
- Power cord
- Ethernet cable (L ~2 m)
- Connector protection caps
- Quick guide
- Digital support material
- Calibration certificate

Technical Details
8A4248-6.0 HBM: public FS22 DI
1.3 Technical Data
Wavelength Measurement
Range 100 nm (1500 to 1600 nm)
Resolution/Repeatability1) <1 pm
Stability/Reproducibility1) 5 pm
Optical channels 2) 1, 4 or 8
Sample rate All available, user selectable
Possible values (S/s) 1000 500 200 100 50
Max. sensors/OC 31 63 127 127 127
Max. sensors total 48 96 200 400 600
Optical detection Linear (selectable gain steps)
Dynamic range 3) > 25 dB
Laser Source
Optical output power 4)
Single 0 dBm
Quad -3 dBm
Octo -6 dBm
Linewidth < 500 MHz
Connectors
Optical FC/APC or SC/APC
Electrical Standard: Weidmüller Terminal Block
SLDF 5.08 2-way supplied with 100-230V power adapter
and Type F plug cable 5)
Rack-Mountable: C14 (IEC/EN 60320-1) supplied with
Type F plug cable 5)
Communication RJ45 Ethernet
Synchronization NTP
Control
Interface Ethernet (TCP/IP)
Commands SCPI (ASCII textual strings) 6)
Features
OSA trace Continuous (1 S/s)
(Wavelength, absolute power) 7)

Technical Details
FS22 DI A4248-6.0 HBM: public 9
Environmental
Operation temperature 0 to 50 ºC
Storage temperature -20 to 70 °C
Operation humidity < 90% at 40 ºC
Storage humidity < 95% (non-condensing)
Shock resistance 20 g; 11 ms (EN60068-2-27)
Vibration resistance 8) 2.5 g (EN60068-2-6)
Mechanical
Dimensions (w x h x d) Standard: 155 x 125 x 275 mm
Rack-Mountable: 483 x 88 x 400 mm
Mounting Standard: 6 screws M6
Rack-Mountable: 19" rack mountable (2U)
Weight Standard: 4.5 kg (w/o mounting brackets)
Rack-Mountable: 7 kg
Enclosure Aluminum (IP20)
Power
Voltage Standard: 11-36 VDC
Rack-Mountable: 100-240 VAC 50-60 Hz
Consumption 4)
Nominal 9) 22.5 W
Stand by 2 W
1) As described in HBM FiberSensing Technical Note "Definitions for Measurement Quality".
2) With simultaneous acquisition.
3) Considered as the ratio between the optical power emitted at an optical channel and the minimum
detectable optical power reflected by a fiber Bragg grating.
4) Typical values.
5) Different plug format can be added upon request.
6) Standard Commands for Programmable Instruments.
7) Full spectrum trace with 7050 points acquired over the 100 nm range.
8) Sinusoidal vibration.
9) Peak consumption may reach 50 W (during startup).

Regulatory and Certification Considerations
10 A4248-6.0 HBM: public FS22 DI
2 Regulatory and Certification Considerations
2.1 Environment Considerations
2.1.1 Disposal of your Old Appliance
When the attached symbol combination - crossed-out
wheeled bin and solid bar symbol is attached to a product
it means the product is covered by the European Direc
tive 2002/96/EC and is applicable in the European Union
and other countries with separate collection systems.
All electrical and electronic products should be disposed
of separately from the municipal waste stream or house
hold via designated collection facilities appointed by the
government or the local authorities. The correct disposal
of your old appliance will help prevent potential negative
consequences for the environment and human health.
For more detailed information about disposal of your old
appliance, please contact your city office, waste disposal
service or distributor that purchased the product.
HBM FiberSensing is a manufacturer registered in the
ANREEE - "Associação Nacional para o Registo de
Equipamentos Eléctricos e Electrónicos" under number
PT001434. HBM FiberSensing celebrated a "Utente"
type contract with Amb3E - "Associação Portuguesa de
Gestão de Resíduos de Equipamentos Eléctricos e Elec
trónicos", which ensures the transfer of Electrical and
Electronic appliance waste management, i.e. placing
Electronic and Electrical appliances in the Portuguese
market, from the manufacturer HBM FiberSensing to
Amb3E.
Tabla de contenidos
Otros manuales de Instrumento de medición de HBM

HBM
HBM MC3 Manual de usuario

HBM
HBM DMP41 Manual de usuario

HBM
HBM Genesis GEN5i Manual de usuario

HBM
HBM CMA Series Manual de usuario

HBM
HBM CFT Manual de usuario

HBM
HBM HLC Manual de usuario

HBM
HBM MVD2555 Manual de usuario

HBM
HBM T40B Manual de usuario

HBM
HBM MP60 Manual de usuario

HBM
HBM Z6AM Manual de usuario
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario