DIAGNOSTIC LEDs
iagnostic LE s are active only in test mode.
BLUE Flash when NUBI is in test mode.
GREEN Flash when the smoke cartridge is triggered.
RE Warnings.
24H OUTPUT
24H output is a clear contact normally closed when the
NUBI 4.0 box is closed, it will open when the box will be
opened. When the SW8 is set to ON, tamper output is
disabled (output is always closed).
TEST MODE
Set the IP SW7 to ON to activate the test mode. As soon
as the device enters test mode, all the LE s and the
buzzer will flash 8 times. If the voltage is below 10V, the
red LE and the buzzer will remains ON, otherwise the
green LE will flash one time, then the smoke cartridge
will be tested. When it is empty the red LE and the
buzzer will light up and the green LE on the validation
board will be OFF. When the smoke cartridge is not empty
the green LE on validation board will flash, the test will
continue and the BLUE led will flash slowly, one time each
second, to indicate the test mode is activated.
When, according to the programming mode of SW1 and
SW2, the CSI input will trigger the smoke delivery, the
GREEN LE will flash for 1 second to indicate the
simulation of the activation of the smoke cartridge.
Remember to activate the operating mode (DIP SW7
OFF) at the end of testing.
SMOKE CARTRIDGE REPLACEMENT
When a smoke cartridge is empty, it must be replaced with
a new one. The smoke cartridge is supplied with the
validation card welded to the ends of the wires. Only in test
mode (SW7 ON) the green LE on validation board will
flash when the cartridge is full, OFF when it is empty and
needs to be replaced.
Remove the power suppl and wait at least 3
minutes before replacing the smoke cartridge.
1) Remove from the motherboard the old validation
card soldered onto the wires of the empty smoke
cartridge.
2) Insert the new validation card soldered onto the
wires of the new cartridge.
COMMISSIONING
We advise to perform a test (see previous chapter Test
mode) before perform a definitive commissioning of the
device. Set the IP SW7 to OFF to switch in operating
mode. We advise to remove the adhesive that protects
smoke exit hole of the smoke cartridge.
WARNING PROCEDURE TO PREVENT SMOKE
EMISSION AT THE POWER UP
uring the first 30 minutes after power the device, there
is a special function to prevent unwanted smoke
emissions, for example due to wiring errors.
When the smoke activation condition occurs during this
time, instead of immediately emitting smoke, a warning
procedure starts and the red LE flashes for 120
seconds.
It will be possible to stop the activation by opening the
box and setting the IP SW7 to ON or, in case of
difficulty, it will also be possible to unplug the smoke
cartridge validation card from the motherboard.
If this warning procedure is not interrupted, at the end of
the 120 seconds we will have the emission of smoke.
Each time this warning procedure is activated, the 30-
minute timer is regenerated to allow an additional 30
minutes of test time.
MAINTENANCE
We recommend replacing the smoke capsule every 5
years using only the original replacement.
WARRANTY
SMARTEK s.r.l. It guarantees its products against all
manufacturing defects for a period of 30 months from the
production date shown on the label.
RECOMMENDATIONS
Before leaving, ventilate the rooms thoroughly after the
smoke has been delivered.
TECHNICAL SPECIFICATIONS
Power supply From 10 to 15V C
< 1mW
Size 12cm x 17cm x 14cm
Saturable volume 100m3
Weight 760g
Smoke average delivery time 25sec
Operating temperature From 0°C to +45°C
Storage temperature From -20°C to +55°C
Maximum relative humidity 70%
Inputs CSI – Immediate action
Outputs 24H – Tamper