NB40LPS1
REV 01 – Nov. 2018 - ENGLISH
OUTPUTS
BL output s act ve when the battery s low. SW5 sets the
output log c.
24H output s a clear contact normally closed when the
NUBI 4.0 box s closed, t w ll open when the box w ll be
opened. When the SW8 s set to ON, tamper output s
d sabled (output s always closed).
TEST MODE
Set the DIP SW7 to ON to act vate the test mode. As soon
as the dev ce enters test mode, all the LEDs and the
buzzer w ll flash 8 t mes, then w ll be performed the battery
test:
•Green LED flash 3 t mes: full charge
•Green LED flash 2 t mes: med um charge.
•Green LED flash 1 t me: qu te low.
•RED LED + Buzzer: Battery must be replaced
When the battery s n good cond t on, the smoke cartr dge
w ll be tested, when t s empty the red LED and the buzzer
w ll l ght up and the green LED on the val dat on board w ll
be OFF. When the smoke cartr dge s not empty the green
LED on val dat on board w ll flash, the test w ll cont nue
and the BLUE led w ll flash slowly, one t me each second,
to nd cate the test mode s act vated.
When, accord ng to the programm ng mode of SW1 and
SW2, the CSI nput w ll tr gger the smoke del very, the
GREEN LED w ll flash for 1 second to nd cate the
s mulat on of the act vat on of the smoke cartr dge.
Remembe to activate the ope ating mode (DIP SW7
OFF) at the end of testing.
SMOKE CARTRIDGE REPLACEMENT
When a smoke cartr dge s empty, t must be replaced w th
a new one. The smoke cartr dge s suppl ed w th the
val dat on card welded to the ends of the w res. Only n test
mode (SW7 ON) the green LED on val dat on board w ll
flash when the cartr dge s full, OFF when t s empty and
needs to be replaced.
Remove the NUBI 4.0 batte y powe supply and wait
at least 3 minutes befo e eplacing the smoke
ca t idge.
1) Remove from the motherboard the old val dat on
card soldered onto the w res of the empty smoke
cartr dge.
2) Insert the new val dat on card soldered onto the
w res of the new cartr dge.
Commissioning
We adv se to perform a test (see prev ous chapter Test
mode) before perform a def n t ve comm ss on ng of the
dev ce. Set the DIP SW7 to OFF to sw tch n operat ng
mode. We adv se to remove the adhes ve that protects
smoke ex t hole of the smoke cartr dge.
WARNING PROCEDURE TO PREVENT SMOKE
EMISSION AT THE POWER UP
Dur ng the f rst 30 m nutes after power the dev ce, there
s a spec al funct on to prevent unwanted smoke
em ss ons, for example due to w r ng errors.
When the smoke act vat on cond t on occurs dur ng th s
t me, nstead of mmed ately em tt ng smoke, a warn ng
procedure starts and the red LED flashes for 120
seconds.
It w ll be poss ble to stop the act vat on by open ng the
box and sett ng the DIP SW7 to ON or, n case of
d ff culty, t w ll also be poss ble to unplug the smoke
cartr dge val dat on card from the motherboard.
If th s warn ng procedure s not nterrupted, at the end of
the 120 seconds we w ll have the em ss on of smoke.
Each t me th s warn ng procedure s act vated, the 30-
m nute t mer s regenerated to allow an add t onal 30
m nutes of test t me.
MAINTENANCE
We recommend replac ng the smoke capsule every 5
years us ng only the or g nal replacement.
WARRANTY
SMARTEK s.r.l. It guarantees ts products aga nst all
manufactur ng defects for a per od of 30 months from the
product on date shown on the label.
RECOMMENDATIONS
Before leav ng, vent late the rooms thoroughly after the
smoke has been del vered.
TECHNICAL SPECIFICATIONS
Power supply 3,6V l th um battery AA
M n mum operat ng voltage 2,2V
Battery low output threshold 2,6V
Autonomy About 10 years
S ze 12cm x 17cm x 14cm
Saturable volume 100m3
We ght 760g
Smoke average del very t me 25sec
Operat ng temperature From 0°C to +45°C
Storage temperature From -20°C to +55°C
Max mum relat ve hum d ty 70%
Inputs CSI – Immed ate act on
Outputs 24H – Tamper
BL – Battery low