NB40F3UX – NB40S2UX – NB40LP2UX - NB40LPS2UX
REV 01 – Dec. 2019 - ENGLISH
LED will flash rapidly. At the second alarm event within this
period, the green LED will flash for 1 second to sim late
smoke delivery.
Remember to activate the normal operating mode
(DIP S 7 OFF) at the end of the test.
TEST CAPSULE (NCBT)
The test caps le (NBCT) is an accessory that allows yo
to test the operation of the device in operating mode. It
sim lates the behavior of the smoke caps le, b t instead
of delivering the smoke it emits a series of beeps and t rns
on its LEDs. NUBI 4.0 with the test caps le is immediately
operational and ignores the 30 min te safety time
described below.
COMMISSIONING
We recommend carrying o t a test (see the previo s
chapter Testing mode) before carrying o t a final
commissioning of the device. Set DIP SW7 to OFF to
switch to operating mode. The removal of the adhesive
that protects the smoke exit hole of the smoke caps le is
optional, if it is removed the smoke emission starts silently,
otherwise the caps le is better protected against h midity
and the delivery of the smoke will start with a light "bang",
like a shot of a lightning g n.
NO UN ANTED TRIGGER
NUBI 4.0 PREVENTS UNDESIRABLE SMOKE
EMISSIONS ON THE FIRST PO ER-ON, DUE TO
IRING ERRORS. IN ADDITION IT ALLO S TO
PERFORM FUNCTIONAL TESTS ITHOUT
ACTIVATING THE SMOKE CAPSULE.
In the first 30 min tes after s pplying power, NUBI enters a
special safety operating mode. D ring this period the
caps le triggering is preceded by a warning signal, the
b zzer emits an intermittent so nd for 120 seconds and
the red LED flashes. To stop smoke activation, simply do
one of the following:
•Place SW7 ON, even for a moment
•Disarm the alarm (inp t SI) when the alarm was
ca sed by the ALL-IN inp t and/or the infrared
sensor.
•Give a new imp lse to the CSI inp t when the
alarm was ca sed by a previo s imp lse on this
inp t.
•Remove the power to the device.
If this warning proced re is not interr pted, smoke will be
delivered at the end of the 120 seconds.
Each time the warning signal is triggered, the 30 min te
timer is regenerated to allow for another 30 min tes of
safety operating mode.
MAINTENANCE
We recommend replacing the smoke caps le every 5
years sing only the original replacement.
SMOKE CAPSULE REPLACEMENT
When a smoke caps le is exha sted, it m st be replaced
with a new one, sing only original spare parts.
Remove the power supply or the battery and wait at
least 10 seconds before replacing the smoke
capsule.
ARRANTY
SMARTEK s.r.l. g arantees its prod cts against all
man fact ring defects for a period of 30 months from the
date of the prod ction batch indicated on the label.
RECOMMENDATIONS
Before leaving, ventilate the rooms thoro ghly after the
smoke has been delivered.
ADVANCED IRING
When the inp ts are driven in voltage, it is recommended
to respect the following thresholds:
12VDC Battery 3,6V
Min V Max V Min V Max V
Level 0 GND 2,0V GND 0,5V
Level 1 8,0V +VCC 1,9V +Vbatt
When only one alarm o tp t is available from the alarm
control nit b t not the system stat s, it is possible to drive
the SI and LL-IN inp ts in parallel sing this o tp t,
therefore NUBI 4.0 will deliver smoke when it detects a
movement with the embedded infrared sensor, b t only
while the alarm o tp t remains active. Ca tion, if the
control panel o tp t also become active with the tamper
alarm, NUBI 4.0 will be activated also for this condition.
TECHNICAL SPECIFICATIONS
Power s pply (12VDC
models)
From 10 to 15VDC
< 0,1mA
Power s pply (Battery
models)
3,6V lithi m battery AA
s ch as SAFT LS14500
A tonomy abo t 10 years
Size 12cm x 17cm x 14cm
Sat rable vol me 100m3
Weight 760g
Smoke average delivery time 25sec
Operating temperat re From -20°C to +70°C
Maxim m relative h midity 90%
Inp ts 3
O tp ts 3