promobot ThermoControl Plus Manual de usuario

Promobot
ThermoСontrol
Plus
Autonomous Screening Station
for Temperature Measurement
www.thermocontrol.ai
PROMOBOT CORP
86 Tomlinson Rd, B1
Huntingdon Valley, PA 19006
+1-855-5-ROBOTS
info@thermocontrol.ai

Contents
1. General information ............................4
1.1. Description and primary functions .............................................4
1.2. How ThermoСontrol Plus measures temperature ..............................5
1.3. Technical characteristics ......................................................7
1.4. Design .......................................................................8
1.5. Design and functionality ......................................................9
2. Intended use ............................... 10
2.1. Usage limits ................................................................. 10
2.2. Assembly, setup and launch .................................................10
2.2.1. Preliminary safety measures...................................................10
2.2.2. Assembly ..................................................................... 11
2.2.3. Height adjustment........................................................... 25
2.2.4. Operational requirements ................................................... 26
2.2.5. Power up..................................................................... 27
2.2.6. Initial setup .................................................................. 28
Connecting device via Wi-Fi .................................................. 29
Temperature settings.........................................................30
Save photos to the database ..................................................32
Language settings............................................................ 33
Sound settings ...............................................................34
Welcome Screen conguration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.2.7. Additional settings ........................................................... 36
Device registration ........................................................... 36
Removing device from the server ............................................38
Device information overview .................................................40
Updates installation .......................................................... 42
Additional languages .........................................................43
Single spot measurement ....................................................44
Light mode ...................................................................45
Advanced Settings ........................................................... 47
2.3. Guidelines ..................................................................48
2.3.1. Operator guidelines ..........................................................48
2.3.2. User guidelines ..............................................................48
2.4. Safety guidelines............................................................53
2.4.1. In the event of device failure.................................................. 53
2.4.2. In case of emergency operation ............................................. 53
3. Maintenance ...............................54
4. Warranty .................................55
3
Promobot ThermoСontrol Plus. User Manual
2

T h erm o Сo nt ro l Plu s ( ThermoСontrol or device) is a screening station for automatic contactless
face temperature measurement with facial recognition functionality.
The device performs a facial skin temperature measurement at a distance of up to 25 cm
without interaction with another person or with the device’s surface. It can be set up to
automatically save the person’s photo and the results in a database. It will notify the operator
if the user’s face temperature is above average. It can store the results with the person’s full
name and be integrated with access control systems. The station adjusts its sensor according
to the user’s height to ensure the proper temperature measurement.
A human body temperature is not constant. It differs not only from person to person, but
from one part of the body to another. For the most accurate results, specialists recommend
measuring temperature in the armpit or rectally. In a high throughput area, these options are
not viable. One of the best solutions is a contactless temperature measurement taken from
a person’s face.
ThermoСontrol is a screening station made for automatic contactless face temperature
measurements.
Human faces don’t have a consistent temperature throughout the surface (Fig. 1). The
manufacturer considered that when developing the screening logic. The device measures
the temperature in 10 points of a person’s face. A temperature sensor moves from the top to
the bottom of the face, starting at the forehead and ending on the lips, determining the most
precise temperature rate. The most accurate measurement is provided when the forehead is
uncovered (Fig. 2).
ThermoСontrol does not measure temperature orally, in the armpit or rectally.
Human’s face may become colder or hotter depending on weather conditions. It is not
recommended to measure temperature immediately upon entering the building; user must
wait until face temperature evens out.
1. General information
1.1. Description and primary functions
1.2. How ThermoСontrol Plus
measures temperature
Fig. 1 Face heatmap
36°C
30°C
4 5
Promobot ThermoСontrol Plus. User Manual

1.3. Technical characteristics*
Name Value
Min dimensions, LWH, cm 1260 х 625 х 550
Max dimensions, LWH, cm 1840 х 625 х 550
Weight, kg 55
Display size, inches, no less than 21.5
Temperature measurement range, °C +36 – +42
Measurement accuracy, °C ±0.2
Measurement speed, seconds 1 – 5
Measurement distance, cm, up to 25
Operating temperature range, °C +18 – +40
Network interface Wi-Fi 802.11ac / Ethernet
Power grid voltage, Volts 220 / 110
Power grid frequency, Hz 50 – 60
Power consumption, W 350
Server storage at the client’s facility Available
Integration with access system Available
Online video calls Available
* The manufacturer reserves the right to change the location of the product’s
built-in computing module, both inside and outside of the device’s casing.
Table 1. Technical characteristics
The following factors affect a healthy person’s body temperature:
■individual metabolism;
■age (small children generally have a higher body temperature);
■clothes;
■outside temperature;
■a time of day (body temperature is lower in the morning and higher at the end of the day);
■physical labor;
■menstrual cycle;
■makeup.
Fig. 2 Measurement guidelines
Make sure you provide the most accurate measurement.
1. Remove your
headwear
4. Remove hair from
your forehead
2. Remove your
glasses and mask
3. Make sure your
forehead is dry
6 7
Promobot ThermoСontrol Plus. User Manual

The station consists of the following elements, as illustrated in Fig. 3.
1.4. Design
Fig. 3 Promobot ThermoСontrol Plus screening station
The ThermoСontrol Plus screening station functions as a complex stationary electrodiagnostic
device connected to the Internet via Ethernet or Wi-Fi supporting the 802.11 AC standard.
In normal operation mode, the screening device:
■detects and recognizes the user’s face;
■automatically adjusts a built-in temperature sensor;
■performs a contactless face skin temperature measurement using the temperature
sensor (with accuracy of 0,2°C within +36 – +38°C temperature range and 0,3°C accuracy
within other temperature ranges measuring human skin or any compatible materials);
■displays instructions during the measurement process;
■displays measurement results;
■color-codes the results (green color if the temperature is normal, red if it is above normal);
■logs a person’s photo and the measurement result and saves them in the database on a
server;
■is remotely monitored via web service;
■noties the station operator in case of high/low temperature via the web service;
■provides video chat functionality between the operator and the user after the
measurement.
The station can operate ofine without connection to the Internet. In this case, remote
monitoring and notications to the operator may function via a local network.
1.5. Design and functionality
Microphone
Temperature sensor
Camera
Display
Standing base
Guide frame
Main section
Speaker
Guide block
Proximity/distance sensor
8 9
Promobot ThermoСontrol Plus. User Manual

Usage limits are imposed in accordance with the main technical characteristics of the device
(Table 1).
The station is a complex electronic device that is constantly connected to the power grid.
The device must be installed on a at, hard surface and grounded. Installation, disassembly,
transportation, preparation for operation, and maintenance of the device are carried out only
when the power cable is disconnected from the socket.
Visual inspection of the main device nodes is mandatory before using the station.
DO NOT operate the station with a malfunctioning power unit and damaged power cord.
The power supply parameters must correspond to the main technical characteristics of the
device. DO NOT operate the station with unstable power grid voltage.
2. Intended use
2.1. Usage limits
2.2.1. Preliminary safety measures
2.2. Assembly, setup and launch
Before the device is assembled, all of its main elements must be removed from the soft
packaging and checked for completeness. Package contents (Table 2) include:
Table 2. Package contents
2.2.2. Assembly
Name Quantity
Standing base (a & b) 1 pc.
ThermoСontrol Plus main section 1 pc.
Display 1 pc.
Rails 2 pcs.
Guide frame 1 pc.
Guide block 1 pc.
Pipe plug 1 pc.
Mounting bolt М4*8 4 pcs.
Mounting bolt М6*8 1 pc.
Mounting bolt М6*12 2 pcs.
Mounting bolt М6*16 8 pcs.
Mounting bolt М6*14 4 pcs.
Mounting bolt М4*12 6 pcs.
Mounting bolt М6*20 2 pcs.
Mounting bolt М8*20 4 pcs.
Washer М8 4 pcs.
Washer М6 4 pcs.
Plastic washer 2 pcs.
Anchor 4 pcs.
Sticky pad 4 pcs.
Toolkit 1 pc.
User manual 1 pc.
Power cord 1 pc.
10 11
Promobot ThermoСontrol Plus. User Manual

Fig. 4.1 Package contents, pt. 1 Fig. 4.2 Package contents, pt. 2
* refer to pic. 10; 13 if a rear panel is angled
* refer to pic. 10.1; 13.1 if a rear panel is rounded
12 13
Promobot ThermoСontrol Plus. User Manual

1
3
2 4
The following steps are needed in order to assemble the device. Numbers next to the images
indicate the assembly steps. These steps must be performed in the order presented.
The assembly process involves lifting heavy objects and circuit wiring.
Please keep that in mind before getting started.
14 15
Promobot ThermoСontrol Plus. User Manual

5 7
6 8
16 17
Promobot ThermoСontrol Plus. User Manual

9 10
10.1
* installing angled panel
* installing rounded panel
18 19
Promobot ThermoСontrol Plus. User Manual
Tabla de contenidos
Otros manuales de Robótica de promobot
Manuales populares de Robótica de otras marcas

STEMCenter USA
STEMCenter USA Pi-Bot v2.00 Manual de usuario

SunFounder
SunFounder PiDog Manual de usuario

Universal Robots
Universal Robots UR5 Manual de usuario

Universal Robots
Universal Robots E Series Manual de usuario

YASKAWA
YASKAWA MOTOMAN-MPL80 II Manual de usuario

EFORT
EFORT ECR5 Manual de instrucciones