Loctite EQ CL42 Manual de usuario

1
EQ CL42 LED Dual Controller
IDH# 2804957
Operating Manual

2
Table of Contents
1Please Observe the Following...................................................................................................3
1.1 Emphasized Sections...........................................................................................................3
1.2 For Your Safety.....................................................................................................................3
1.3 Unpacking and Inspection ..................................................................................................5
1.4 Packing List...........................................................................................................................5
1.5 Features.................................................................................................................................5
1.6 Usage.....................................................................................................................................6
2Description...................................................................................................................................6
2.1 Theory of Operation..................................................................................................................6
2.2 Display, operating elements and connections......................................................................7
3Technical Data.............................................................................................................................8
4Installation....................................................................................................................................9
4.1 Environmental and Operating Conditions..............................................................................9
4.2 Connecting the Unit..................................................................................................................9
5Operation......................................................................................................................................9
5.1 Electrical Connection................................................................................................................9
5.2 Turn on the Unit......................................................................................................................10
5.3 Main Page ................................................................................................................................10
5.4 Parameter Setting Page.........................................................................................................11
5.5 Control Operation Page..........................................................................................................13
6Application Hints.......................................................................................................................14
7Troubleshooting.........................................................................................................................14
8Care and Maintenance .............................................................................................................16
9Accessories and Spare Parts...................................................................................................16
10 Diagrams ....................................................................................................................................17
11 Warranty.....................................................................................................................................19

3
12 Declaration of Conformity........................................................................................................20
1 Please Observe the Following
1.1 Emphasized Sections
Warning!
Refers to safety regulations and requires safety measures that protect the operator
or other persons from injury or danger to life.
Caution!
Emphasizes what must be done or avoided so that the unit or other property is not
damaged.
Notice:
A notice gives recommendations for better handling of the unit during operation or
adjustment as well as for service activities.
1.2 For Your Safety
For safe and successful operation of the unit, read these instructions
completely. If the instructions are not observed, the manufacturer can assume no
responsibility.
Do not expose the connecting cable to heat, oil, or sharp edges.
Make sure the Unit stands stable and secure.
Use only original equipment replacement parts.
Always disconnect the power supply before servicing the unit.
Observe general safety regulations for the handling of chemicals such as
Loctite®adhesives and sealants. Observe the manufacturer’s instructions as stated
in the Safety Data Sheet.
While under warranty, the unit may be repaired only by an authorized Loctite
service representative.

4
WARNING!
It is the responsibility of the user to ensure that all devices being driven by the LED Flood
Controller are set-up in a safe manner.
The manufacturer is in no way responsible for injuries or damage to persons or property
resulting from devices being driven by the LED Flood Controller.
For safe and successful operation of the unit, read these instructions completely. If the
instructions are not observed, the manufacturer can assume no responsibility.
Removing, bypassing or putting out of operation any of the safety devices can result in
radiation damage to persons and damage to the unit and is therefore prohibited!
Do not look directly at LED-UV light, or at LED-UV light reflected in a mirror or other
reflective surface. Doing so could cause eye damage.
Install the LED head in a way that humans are not exposed to LED-UV light.
Exposure could injure the skin or cause other injury.
If there is a risk of the LED-UV light being exposed to UV reflective light, place the product
inside a cover with proper reflectance and heat characteristics to block that reflected light.
When operating the controller, set up the system so that the path of the LED-UV light is not
at eye level.
It is strongly recommended to place a protective barrier around the product so that people
cannot approach it while it is operating.
Wear protective UV glasses and other protective clothing during operation.
Never operate this product in a manner not described in this manual. Doing so risks
exposure to LED UV light.

5
Damage to the power cord or the housing can result in contact with live electrical parts.
Check the power cord and the unit before each use. If the power cord or the unit is
damaged, do not operate! Replace a damaged power cord with a new one.
The unit may be opened and repaired only by authorized service personal.
1.3 Unpacking and Inspection
Carefully unpack the Loctite®EQ CL42 LED Dual Controller and examine the items
contained in the carton. Inspect the unit for any damage that might have occurred in
transit. If such damage has occurred, notify the carrier immediately. Claims for
damage must be made by the consignee to the carrier and should be reported to the
manufacturer.
1.4 Packing List
1.4.1 EQ CL42 LED Dual Controller x 1
1.4.2 Equipment Manual x 1
1.4.3 Power Cord x 1
1.4.4 Footswitch x 1
1.5 Features
1.5.1 Capacity for up to two UV LED Heads.
1.5.2 Works with Loctite EQ CL42 Flood Heads.
1.5.3 Touch screen HMI
1.5.4 3 running modes: Timer, Continue and Advance.
1.5.5 Friendly UI

6
1.6 Usage
The Loctite EQ CL42 LED Dual controller is used with the EQ CL42 365nm and
405nm LED flood heads for use with light cure products that cure when exposed to
ultraviolet and/or visible light. The system can be operated manually, operated with
the integrated timer, or controlled with an external switch. The system is designed
for intermittent or constant duty cycle.
2 Description
2.1 Theory of Operation
The EQ CL42 LED Flood Controller provides electrical power to the LED’s through the
connecting cable (not included).
Indicator lights located on the front panel of the power supply provide visual confirmation
that the LED’s are in or out of their acceptable range. In the event of temperature fault the
power supply will automatically shut down to protect the LED array.
When the cure cycle is initiated, light is immediately irradiated at or near maximum intensity
from the LED’s.
The curing process begins when the adhesive is placed under the LED’s. The two primary
variables that control the curing process are the time of exposure and the strength of the
light (irradiance). For a given irradiance, the exposure time required to fully cure the
adhesive depends primarily on the properties of the adhesive and the optical properties of
the substrate that the light is transmitted through.

7
2.2 Display, operating elements and connections
1. Power Supplier Inlet and Fuse
2. Power Switch ON/OFF
3. Socket XS3: LED Head
4. Socket XS1: Start for CH1(The footswitch is connected here).
5. Socket XS2: Start for CH2(The footswitch is connected here).
6. Socket XS5: RS232
7. Socket XS9: PLC Interface
8. Cooling Fan
9. Screen.

8
3 Technical Data
Dimensions (L x H x W): 217x123x307.4 mm
Total weight: lbs. (Kg) 14
Operating voltage: 110~240 VAC 50/60Hz
Power consumption: 1100 Watts
Operating Temperature: +10 °C to +40 °C (+50 °F to +104 °F)
Storage Temperature: -10 °C to +60 °C (+14 °F to +140 °F)

9
4 Installation
Before using the equipment for the first time check it carefully for signs of
external damage. If any shipping damage is found DO NOT USE THE EQUIPMENT –
return it to your supplier immediately.
4.1 Environmental and Operating Conditions
-No direct sunlight.
-Recommend operating temperature; +10 °C to +40 °C (+50 °F to +104 °F)
-No splashing waters.
-No suddenly temperature changes, vibration and shocks.
-No high magnetic and intense electric.
4.2 Connecting the Unit
-Connect Sub D 9 pin connector of the footswitch 97201 or a higher-ranking controller
to XS 1.
-Connect the 15 pin Sub D connector to the LED Head Array to XS 31~34.
-Connect power cord to the appropriate plug.
5 Operation
5.1 Electrical Connection
-Plug the female end of the LED power cable into the 15 pin D-sub connector located
on the rear panel of the LED Array housing. Plug the male end into the 15 pin D-sub
connector located on the rear panel of the controller. Make sure that the
connections at both ends are secure.
-Plug the AC power cord into the back of the controller and connect to power source.
-For manual operation, plug the footswitch into the 9 pin D-sub connector marked
XS1, located on the rear panel of the CL30 controller.

10
-For automated control, connect external PLC output relay to pins one and nine of
XS1.
5.2 Turn on the Unit
Observe the operating manual of the LED head used.
Turn the power switch 2 to ON
5.3 Main Page
1. Channel Manual Switch
2. Channel
3. LED head running Mode: CONTINUE, TIMER, ADVANCE
4. Intensity percentage
5. Time (Exposure time)
6. Temperature (LED head temperature - For indication only)
7. Channel Status Display
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Controladores de Loctite

Loctite
Loctite 2257357 Manual de usuario

Loctite
Loctite 97102 Manual de usuario

Loctite
Loctite Single CureJet Manual de usuario

Loctite
Loctite 97152 Manual de usuario

Loctite
Loctite CL10 Manual de usuario

Loctite
Loctite 98521 Manual de usuario

Loctite
Loctite 1461974 Manual de usuario

Loctite
Loctite CL10 Manual de usuario