KYLAND SICOM6448G Series Instrucciones de montaje

SICOM6448G Series Industrial Ethernet
Switches Hardware Installation Manual
Publication Data: Nov. 2016
Version: V1.0

SICOM6448G Series Industrial Ethernet Switches
Hardware Installation Manual
Disclaimer: Kyland Technology Co., Ltd. tries to keep the content of this manual as
accurate and as updated as possible. This document is not guaranteed to be error-free, and
we reserve the right to amend it without notice to users.
All rights reserved.
No part of this documentation may be excerpted, reproduced, translated, annotated or
duplicated, in any form or by any means without the prior written permission of KYLAND
Corporation.
Copyright © 2016 Kyland Technology Co., Ltd.

Notice for Safety Operation
The product performs reliably as long as it is used according to the guidance. Artificial
damage or destruction of the device should be avoided. Before using the device, read this
manual carefully for personal and equipment safety. Please keep the manual for further
reference. Kyland is not liable to any personal or equipment damage caused by violation of
this notice.
Do not place the device near water sources or damp areas. Keep the ambient relative
humidity within the range from 5% to 95% (non-condensing).
Do not place the device in an environment with high magnetic field, strong shock, or high
temperature. Keep the working and storage temperatures within the allowed range.
Install and place the device securely and firmly.
Please keep the device clean; if necessary, wipe it with a soft cotton cloth.
Do not place any irrelevant materials on the device or cables. Ensure adequate heat
dissipation and tidy cable layout without knots.
Wear antistatic gloves or take other protective measures when operating the device.
Avoid any exposed metal wires because they may be oxidized or electrified.
Install the device in accordance with related national and local regulations.
Before power-on, make sure the power supply is within the allowed range of the device.
High voltage may damage the device.
Power connectors and other connectors should be firmly interconnected.
Do not plug in or out the power supply with wet hands. When the device is powered on,
do not touch the device or any parts with wet hands.
Before operating a device connected to a power cable, remove all jewelry (such as rings,
bracelets, watches, and necklaces) or any other metal objects, because they may cause
electric shock or burns.
Do not operate the device or connect or disconnect cables during an electrical storm.
Use compatible connectors and cables. If you are not sure, contact our sales or
technical support personnel for confirmation.

Do not disassemble the device by yourself. When an anomaly occurs, contact our sales
or technical support personnel.
If any part is lost, contact our sales or technical support personnel to purchase the
substitute. Do not purchase parts from other channels.
Dispose of the device in accordance with relevant national provisions, preventing
environmental pollution.
Specification of the internal fuses in this equipment: 3.15A/300V.
In the following cases, please immediately shut down your power supply and contact your
Kyland representative:
Water gets into the equipment.
Equipment damage or shell damage.
Equipment operation or performance has abnormally changed.
The equipment emits odor, smoke or abnormal noise.
The following information applies when operating this device in hazardous locations:
Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or
nonhazardous locations only.
Cet appareillage est utilisable dans les emplacements de Classe I, Division 2, Groupes A, B,
C et D, ou dans les emplacements non dangereux seulement.
WARNING: EXPLOSION HAZARD
Do not disconnect equipment while the circuit is live or unless the area is known to be
free of ignitable concentrations.
Substitution of any component may impair suitability for Class I, Division 2.
AVERTISSEMENT: RISQUE D'EXPLOSION
Avant de deconnecter l'equipement, couper le courant ou s'assurer que l'emplacement
est designe non dangereux.
La substitution de composants peut rendre ce materiel inacceptable pour les
emplacements de Classe I, Division 2.

I
Contents
1 Product Overview...............................................................................................................2
2 Structure and Interface.......................................................................................................3
2.1 Front Panel ..................................................................................................................3
2.2 Rear Panel...................................................................................................................4
3 Switch Installation...............................................................................................................5
3.1 Dimension Drawing......................................................................................................5
3.2 Mounting Modes and Steps .........................................................................................6
4 Connection .........................................................................................................................9
4.1 10/100/1000Base-T(X) Ethernet Port...........................................................................9
4.2 1000Base-X, 10/100/1000Base-T(X) SFP slot...........................................................10
4.3 1000Base-X, 10/100/1000Base-T(X) Combo port......................................................13
4.4 10GBase-X SFP+ port ...............................................................................................14
4.5 Console Port ..............................................................................................................14
4.6 Grounding..................................................................................................................15
4.7 Power Terminal Block................................................................................................16
4.8 Alarm Terminal Block.................................................................................................17
5 LEDs.................................................................................................................................19
6 Switch Access ..................................................................................................................22
6.1 Access through Console Port.....................................................................................22
6.2 Access through Telnet ...............................................................................................24
6.3 Access through Web..................................................................................................25
7 Basic Features and Specifications....................................................................................26

Product Overview
2
1 Product Overview
SICOM6448G includes a series of high-performance gigabit industrial Ethernet switches
developed by Kyland. The series devices are applicable to rail transit(ground system),
Petrochemical core switching system. The series switches support high density gigabit ports
and flexible configuration of gigabit optical ports and gigabit electrical ports. All the devices
meet the requirements stipulated in the EN50121-4 and other industrial standards.
SICOM6448G provides powerful network management functions. The devices can be
managed through CLI, Telnet, Web, and SNMP-based network management software.
The series switches support 2U rack mounting by front/rear panel.
Table 1 SICOM6448G configuration table
Product version
SICOM6448G-Ports-PS1-PS2
SICOM6448G-C-Ports-PS1-PS2
Code definition
Code type
C
three proofing coatings
Ports
4X20G28GE、4X8G24GX16GE、20G28GE、8G24GX16GE
NOTE
:
4X8G24GX16GE
:
four 10GBase-X SFP+
;
eight 10/100/1000Base-T(X)combo ports
;
twenty-four 1000Base-X
,
10/100/1000Base-T(X) SFP ports
;
sixteen 10/100/1000Base-T(X) ports.
PS1:Input power 1
HV(220AC/DCW)
PS2:Input power 2
HV(220AC/DCW)、NA
Note:
For the product information listed in these tables, we reserve the right to amend it without notice.
To obtain the latest information, you can contact our sales or technical support personnel.

Structure and Interface
3
2 Structure and Interface
Caution:
It is recommended to purchase the port dustproof shield (optional) to keep ports clean and
ensure device performance.
2.1 Front Panel
Figure 1 Front Panel
Table 2 Description of the Front Panel
No.
Identifier
Description
(1)
Alarm
Alarm LED
(2)
PWR2
Power 2 LED
(3)
Run
Running LED
(4)
PWR1
Power 1 LED
(5)
XG(1-4)
four 10GBase-X SFP+ port connection status LEDs
(6)
(1-48)Link/ACT
Forty-eight 1000Base-X port connection status LEDs;
(7)
Console
One console port.

Structure and Interface
4
2.2 Rear Panel
Figure 2 Rear Panel
Table 3 Description of the Rear Panel
No.
Identifier
Description
(1)
GE(1-16)
Sixteen 10/100/1000Base-T(X) Ethernet interface;
(2)
GX/GE(17-24)
Eight 1000Base-X, 10/100/1000Base-T(X)Combo interface;
(3)
XG(1-4)
Four 10GBase-X SFP+ interface;
(4)
FAULT
Alarm terminal block;
(5)
GX(25-48)
Twenty-four 1000Base-X, 10/100/1000Base-T(X)SFP
interface;
(6)
PWR1 / PWR2
Power terminal block;
(7)
Grounding screw.

Switch Installation
5
3 Switch Installation
3.1 Dimension Drawing
Figure 3 Dimensions (unit: mm)
Caution:
As part of the heat dissipation system, the switch housing becomes hot during operation.
Please use caution when coming in contact and avoid covering the switch housing when the
switch is running.
The figures in this manual are only for reference.

Switch Installation
6
3.2 Mounting Modes and Steps
The series switches support rack mounting by front/rear panel. The following uses mounting
by front panel as an example to describe mounting steps. The steps for mounting by rear
panel are similar to those for mounting by front panel. Before installation, make sure that the
following requirements are met.
1) Environment: temperature (-20℃to 60℃), ambient relative humidity (5% to 95%,
non-condensing)
2) Power requirement: The power input is within the voltage range of the switch.
3) Grounding resistance: <5
4) No direct sunlight, distant from heat source and areas with strong electromagnetic
interference.
5) Devices are to be installed in an authority certified enclosure and accessible only by the
use of a tool.
6) Devices should be installed and accessed by service personnel or users who have been
instructed about the reasons for the restrictions applied to the location and about any
precautions that shall be taken.
Installing Mounting Brackets
The mounting brackets for this series switches support two mounting positions, as indicated
by the two dashed boxes in the following figure. You can select either of the mounting
positions as needed.
Figure 4 Mounting Bracket
You can select the screw holes for front or rear panel mounting to install the mounting
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Cambiar de KYLAND

KYLAND
KYLAND Aquam8012A-1U Series Instrucciones de montaje

KYLAND
KYLAND Ruby3A Instrucciones de montaje

KYLAND
KYLAND Aquam5G Series Instrucciones de montaje

KYLAND
KYLAND SICOM3000S Instrucciones de montaje

KYLAND
KYLAND Aquam5 Series Instrucciones de montaje

KYLAND
KYLAND SICOM6432G Series Instrucciones de montaje

KYLAND
KYLAND Opal5G Series Instrucciones de montaje

KYLAND
KYLAND SICOM3014GV Instrucciones de montaje

KYLAND
KYLAND SICOM3008GV Series Instrucciones de montaje

KYLAND
KYLAND Aquam5S Series Manual de usuario