KYLAND SICOM6432G Series Instrucciones de montaje

SICOM6432G/3432G Series Industrial
Ethernet Switches Hardware Installation Manual
Publication Date: Apr. 2020
Version: V1.0
No.: 112020177

SICOM6432G/3432G Series
Industrial Ethernet Switches Hardware Installation Manual
Disclaimer: Kyland Technology Co., Ltd. tries to keep the content of this manual as
accurate and as updated as possible. This document is not guaranteed to be error-free, and
we reserve the right to amend it without notice to users.
All rights reserved. No part of this documentation may be excerpted, reproduced, translated,
annotated or duplicated, in any form or by any means without the prior written permission of
KYLAND Corporation.
Copyright © 2020 Kyland Technology Co., Ltd.

I
Notice for Safety Operation
The product performs reliably as long as it is used according to the guidance. Artificial
damage or destruction of the device should be avoided. Before using the device, read this
manual carefully for personal and equipment safety. Please keep the manual for further
reference. Kyland is not liable to any personal or equipment damage caused by violation of
this notice.
Do not place the device near water sources or damp areas. Keep the ambient relative
humidity within the range from 5% to 95% (non-condensing).
Do not place the device in an environment with high magnetic field, strong shock, or high
temperature. Keep the working and storage temperatures within the allowed range.
Install and place the device securely and firmly.
Please keep the device clean; if necessary, wipe it with a soft cotton cloth.
Do not place any irrelevant materials on the device or cables. Ensure adequate heat
dissipation and tidy cable layout without knots.
Wear antistatic gloves or take other protective measures when operating the device.
Avoid any exposed metal wires because they may be oxidized or electrified.
Install the device in accordance with related national and local regulations.
Before power-on, make sure the power supply is within the allowed range of the device.
High voltage may damage the device.
Power connectors and other connectors should be firmly interconnected.
Do not plug in or out the power supply with wet hands. When the device is powered on,
do not touch the device or any parts with wet hands.
Before operating a device connected to a power cable, remove all jewelry (such as rings,
bracelets, watches, and necklaces) or any other metal objects, because they may cause
electric shock or burns.
Do not operate the device or connect or disconnect cables during an electrical storm.
Use compatible connectors and cables. If you are not sure, contact our sales or
technical support personnel for confirmation.

II
Do not disassemble the device by yourself. When an anomaly occurs, contact our sales
or technical support personnel.
If any part is lost, contact our sales or technical support personnel to purchase the
substitute. Do not purchase parts from other channels.
Dispose of the device in accordance with relevant national provisions, preventing
environmental pollution.
In the following cases, please immediately shut down your power supply and contact your
Kyland representative:
Water gets into the equipment.
Equipment damage or shell damage.
Equipment operation or performance has abnormally changed.
The equipment emits odor, smoke or abnormal noise.
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.

III
Contents
1 Product Overview.............................................................................................................. 1
2 Structure and Interface...................................................................................................... 4
3 Mounting............................................................................................................................ 5
3.1 Dimension Drawing..................................................................................................... 5
3.2 Mounting Modes and Steps ........................................................................................ 6
4 Connection ........................................................................................................................ 8
4.1 10/100/1000Base-T(X) Ethernet Port.......................................................................... 8
4.2 1000Base-X, 10/100/1000Base-T(X) SFP slot............................................................ 9
4.2.1 Gigabit SFP Optical Module ................................................................................10
4.2.2 Gigabit SFP Electrical Module.............................................................................11
4.3 1000Base-X, 10/100/1000Base-T(X) Combo port......................................................11
4.4 10GBase-X SFP+ port ...............................................................................................12
4.5 Console Port ..............................................................................................................13
4.6 Grounding..................................................................................................................14
4.7 Power Terminal Block................................................................................................14
4.8 Alarm Terminal Block.................................................................................................16
5 LEDs.................................................................................................................................17
6 Switch Access ..................................................................................................................19
6.1 Access through Console Port.....................................................................................19
6.2 Access through Telnet ...............................................................................................21
6.3 Access through Web..................................................................................................22
7 Basic Features and Specifications....................................................................................23

Product Overview
1
1 Product Overview
SICOM6432G/3432G include a series of high-performance 10 Gigabit industrial Ethernet
switches developed by Kyland particularly. The solid closed housing, fanless but heat
dissipation-capable chassis, overcurrent, overvoltage protection for power input, and IP65
protection class, make this series of device widely used in coal industry, factory automation,
highway system and other fields. This series of device support the ring network redundancy
protocol, which provides multiple guarantees for the reliable operation of the system; has a
powerful network management function, and the network management system supports CLI,
Telnet, Web, and SNMP-based network management software. SICOM6432G series are
layer 3 switch that support the layer 3 routing protocol.
The switches support 1U rack mounting.
Table 1 SICOM6432G Models
Model
SICOM6432G-PORT-PS1-PS2
Code definition
Code option
Ports
4X8G8GX16GE, 8G8GX16GE, 4GX24GE, 4X24GE
Note:
4X8G8GX16GE
:
four 10GBase-X SFP+
;
eight 1000Base-X, 10/100/1000Base-T(X)Combo ports
;
eight 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
sixteen 10/100/1000Base-T(X) ports
8G8GX16GE
:
eight 1000Base-X, 10/100/1000Base-T(X)Combo ports
;
eight 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
sixteen 10/100/1000Base-T(X) ports
4GX24GE
:
four 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
twenty-four 10/100/1000Base-T(X) ports

Product Overview
2
4X24GE:
four 10GBase-X SFP+;
twenty-four 10/100/1000Base-T(X) ports
PS1: power input 1
L2(24-48VDC)、HV (220AC/DCW)
PS2: power input 2
L2(24-48VDC)、HV (220AC/DCW)、NA
Table 2 SICOM3432G Models
Model
SICOM3432G-PORT-PS1-PS2
Code definition
Code option
Ports
4X8G8GX16GE, 8G8GX16GE, 4GX24GE, 4X24GE
Note:
4X8G8GX16GE
:
four 10GBase-X SFP+
;
eight 1000Base-X, 10/100/1000Base-T(X)Combo ports
;
eight 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
sixteen 10/100/1000Base-T(X) ports
8G8GX16GE
:
eight 1000Base-X, 10/100/1000Base-T(X)Combo ports
;
eight 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
sixteen 10/100/1000Base-T(X) ports
4GX24GE
:
four 1000Base-X
,
10/100/1000Base-T(X) SFP slots
;
twenty-four 10/100/1000Base-T(X) ports
4X24GE:
four 10GBase-X SFP+;
twenty-four 10/100/1000Base-T(X) ports
PS1: power input 1
L2(24-48VDC)、HV (220AC/DCW)
PS2: power input 2
L2(24-48VDC)、HV (220AC/DCW)、NA

Product Overview
3
Note:
We reserve the right to amend the product information listed in this table without notice. To
obtain the latest information, you can contact our sales or technical support personnel.

Structure and Interface
4
2 Structure and Interface
Caution:
It is recommended to purchase the port dustproof shield (optional) to keep ports clean and
ensure switch performance.
(1)(2)
(5)
(3)
(4)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
Figure 1 Front Panel
Table 3 Description of the Front Panel
No.
Identifier
Description
(1)
Alarm
Alarm LED
(2)
PWR2
Power 2 LED
(3)
PWR1
Power 1 LED
(4)
Run
Running LED
(5)
Console
Console Port
(6)
XG1-XG4
four 10GBase-X SFP+
(7)
GX25-GX32
eight 1000Base-X,10/100/1000Base-T(X) SFP slots
(8)
GE/GX(17-24)
eight 1000Base-X, 10/100/1000Base-T(X)Combo
ports
(9)
GE1-GE16
1
sixteen 10/100/1000Base-T(X) ports
(10)
Power terminal block PWR1/PWR2
(11)
Grounding screw
(12)
FAULT
Alarm terminal block

Mounting
5
3 Mounting
3.1 Dimension Drawing
Figure 2 SICOM6432G&3432G Dimensions (unit: mm)
Caution:
As part of the heat dissipation system, the switch housing becomes hot during operation.
Please use caution when coming in contact and avoid covering the switch housing when the
switch is running.
The figures in this manual are only for reference.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Cambiar de KYLAND

KYLAND
KYLAND SICOM3000A-LITE Instrucciones de montaje

KYLAND
KYLAND Aquam8012A-1U Series Instrucciones de montaje

KYLAND
KYLAND Opal5G Series Instrucciones de montaje

KYLAND
KYLAND KIEN6000T Manual de usuario

KYLAND
KYLAND KIEN1008BA Series Instrucciones de montaje

KYLAND
KYLAND SICOM3008GV Series Instrucciones de montaje

KYLAND
KYLAND SICOM3014GV Instrucciones de montaje

KYLAND
KYLAND Aquam5S Series Manual de usuario

KYLAND
KYLAND SICOM6448G Series Instrucciones de montaje

KYLAND
KYLAND KIEN1026 Instrucciones de montaje