BainUltra THERMASENS TMSU Instrucciones de instalación y funcionamiento



TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL
3
www.bainultra.com
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
table of contents
956, chemin Olivier
Saint-Nicolas (Québec)
G7A 2N1
T 418.831.7701 1.800.463.2187
F 418.831.6623 1.800.382.8587 [email protected]
SAFETY INSTRUCTIONS 4
INSTALLATION
BATH ON DECK 5
ELECTRICAL INSTALLATION • TURBINE
TURBINE WITH GEYSAIRTM 6
TURBINE WITH GEYSAIRTM & AROMACLOUDTM 7 - 8
TURBINE WITHOUT GEYSAIRTM,AND WITH AROMACLOUDTM 9
ELECTRICAL INSTALLATION • THERMASENSTM 10 -11
CONTROLS • INSTALLATION
DOT CONTROLS 12
AROMACLOUDTM 13
USER GUIDE
DOT CONTROLS 14
AROMACLOUDTM 15
TROUBLESHOOTING 16
WARRANTY 17
DRILLING TEMPLATE
AROMACLOUDTM 19

4 Supersedes page 4 of Owner’s Manual
TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL | SAFETY INSTRUCTIONS
InstRUctIons PeRtaInInG to a RIsK of fIRe,
electRocUtIon, oR PeRsonal InJURY
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
• Risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a
Hydro-thermo massage® bathtub equipped with a heater or a ThermaSensTM bath equipped with the WarmTouchShellTM technology.
• Risk of hyperthermia and possible drowning: do not use a Hydro-thermo massage® bathtub equipped with heater or a ThermaSensTM
bath equipped with the WarmTouchShellTM technology immediately following strenuous exercise.
• Risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a Hydro-thermo massage® bathtub
equipped with a heater, or a ThermaSensTM bath equipped with the WarmTouchShellTM technology.
• Risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a Hydro-thermo massage® bathtub
equipped with a heater or a ThermaSensTM bath equipped with the WarmTouchShellTM technology.
• Use this unit only for its intended purposes or as described in this manual. Use only attachments recommended by the manufacturer.
• Risk of hyperthermia and possible drowning. water temperature in excess of 100ºF (38ºC) may be injurious to your health.
Check and adjust temperature before use.
• To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit
unless they are closely supervised at all times.
• To avoid injury, exercise care when entering or exiting the Thermomasseur® or the ThermaSensTM.
• The GeysairTM (option) should always be connected to the hot water intake. If it is not the case, then, the Geysair option should be
deactivated via the bath control.
RISK OF ELECTRICAL SHOCK
• Disconnect electric power before servicing.
• Do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 5’ (1.5 m) of the Thermomasseur®
or the ThermaSensTM.
• Before using the Thermomasseur® or the ThermaSensTM, its exterior construction (podium or skirting) should be finished so that
a bather cannot accidentally come in contact with electrical components (turbine and power module).
• For indoor use only.
ELECTRICAL CONNECTIONS:
• Never drop or insert objects into any openings.
• The Thermomasseur® must be connected only to a supply circuit that is protected by A 15 amp class A ground fault circuit interrupter
(GFCI) and/or 20 amps, depending on the type of Thermomasseur® and options selected. BainUltra ThermaSensTM must be connected
to a circuit protected by a Class A 15 amp ground fault circuit interrupter (GFCI). This interrupter is supplied by a certified electrician
and must be tested on a regular basis in accordance with manufacturer’s instructions. The GFCI ground must be connected.
If defective, do not use the bathtub. Disconnect immediately and call a certified electrician.
• Use 12 AWG (or greater) copper conductors that resist temperatures of at least 194ºF (90ºC).
• Canada only: for permanently connected units. A green-colored terminal (or a wire connector marked g, gr, ground or grounding) is
provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution,
connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size
to the circuit conductors supplying the equipment and be 12 AWG or more.
• All electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and localbuilding
codes and regulations.
• Install in accordance with manufacturer’s installation instructions.
• For Geysair-equipped baths using remote turbine installation (not mounted on the bath), grounding continuity must be tested
between the bath grounding terminal and the bath power supply. Failure to perform the grounding continuity test could
result in serious personal injury.
WARNING
1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © September 2012 BainUltra Inc. All rights reserved. 45100169
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.

THERMOMASSEUR® | TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL
www.bainultra.com
Printed in Canada. Copyright © September 2012 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
Supersedes page 11 of Owner’s Manual 5
bath on decK
PLUMBING INSTALLATION
IMPORTANT • Bath must be completely supported by the floor making sure the edge rests entirely on the structure.
• Bath must be levelled.
• Bath is molded with a slope toward drain. If bath is levelled in respect to the deck, the water will
drain completely.
1. INSTALLATION
* See specification sheet of bath for exceptions.
1-1 Prepare the site to connect the plumbing
and turbine.
1-2 Build the (2” x 3”) wooden structure taking
into account the thickness of the ceramic
tiles and the plywood as well as the height
of the bath.
NOTE: Plan air intake for turbine.
1-3 Secure plywood into place with screws
around and above structure.
1-4 Cut inside 1 1/2” of the outside dimensions
of the tub.
1-5 Ensure bath is levelled and that it fits properly
in cutout.
NOTE: Protect turbine and accessories
as you insert bath.
1-6 Install desired finishing materials (ceramic
tiles, granit, marble or other) and top
surface and siding of the deck.
1-7 Set bath back into place and conduct
plumbing and turbine connection.
Edge of bath
Ceramic, marble,
granit or other
Plywood
2” x 3”
structure
1 1/2"
[3.8 cm]
BATH ON DECK - PLUMBING INSTALLATION
NOTE • Baths with AromaCloudTM factory installed by BainUltra may require an additional cutout on the
podium for the AromaCloud housing. This extra cutout is required when the housing is less than
1.5 inch from the edge of the bath.

TURBINE
TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL | TURBINE
1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
6 Supersedes page 27 of Owner’s Manual
TURBINE WITH GEYSAIR - ELECTRICAL INSTALLATION & PLUMBING
tURbIne WIth GeYsaIR
ELECTRICAL INSTALLATION & PLUMBING
The turbine is connected to a 120V circuit.
All electrical connections must be carried out by
a certified electrician in accordance with local
electrical requirements and codes. Special attention
must be given to installation of bath’s power circuit,
and more particularly to the following points:
The electrical system must be connected to an
independent circuit protected by a new 20 AMP
Class A ground fault circuit interrupter (GFCI)
and another one of 15 AMP for additonal options.
This electrical circuit must imperatively be grounded.
CANADA ONLY: for permanently connected
units.
A green-colored terminal (or a wire connector marked g,
gr, ground or grounding) is provided within the terminal
compartment (not applicable if unit supplied with an elec-
tric plug). To reduce the risk of electrocution, connect this
terminal or connector to the grounding terminal of your
electric service or supply panel with conductor equivalent in
size to the circuit conductors supplying the equipment and
be 12 AWG or more. INSTALL THIS UNIT IN ACCORDANCE
WITH THE CANADIAN ELECTRICAL CODE, PART 1.
A service access is necessary. Minimum dimensions
are: 22” x 18” (55 cm x 46 cm) to properly reach all
electrical components of the system.
GROUNDING
ACCESS
CONNECTIONS
PLUMBING
The modules of the electronic controls and the turbine must be
easily accessible at all times. Make all connections as indicated on
diagram below. Ensure that power circuit is disabled before pro-
ceeding with any electrical connections. Electrical cable feeding
bath must be at least N° 12 AWG caliber. Turbine must be con-
nected to its own circuit, which, in turn must be connected
directly in breaker panel without any interrupters or dimmer
switches. Canada only: the junction box must be attached to the
wall at the height of at least 1 1/2” (3.8 cm) from the ground.
The Geysair hose must be connected to the hot water supply
by a qualified plumber and according to the local plumbing code.
A 3/8 inch male or 1/2 inch NPT hose bibb is supplied. For
optimal performance, keep hose length to a minimum. Set
temperature on hot water heater no higher than 140°F/60°C.
For all the houses having to deal with special water condi-
tions (hard, rust, sulfur, etc) the homeowner should already
be aware of the specific measures that should be taken for
all his other appliances using water. The Geysair does not
need other measures than that.

TURBINE
TURBINE | TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL
www.bainultra.com
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
In addition to page 28 of Owner’s Manual 7
MIAPLUS®, MIAMULTI®
CONNECTIONS CONTROLS FOR THERMOMASSEURS®
• Electrical outlet must be installed by a certified electrician. Installation must be conducted in
accordance with all local, provincial/state, and federal building/electrical codes and regulations.
Connect electrical power supply only after all low voltage wiring is properly installed on turbine.
If you did not follow this last step, shut off and then restart your home’s circuit breaker. Turbine
and air pipe should be clear of building materials and wiring.
WARNING
tURbIne WIth GeYsaIR & aRomacloUd
ELECTRICAL INSTALLATION
TURBINE WITH GEYSAIRTM & AROMACLOUDTM - ELECTRICAL INSTALLATION

TURBINE
TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL | TURBINE
1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
8 Supersedes page 29 of Owner’s Manual
ELECTRICAL DIAGRAM
TURBINE WITH GEYSAIRTM & AROMACLOUDTM
Electrical connections for Canada only.
TURBINE WITH GEYSAIRTM & AROMACLOUDT M - ELECTRICAL INSTALLATION
15ACIRCUIT
20ACIRCUIT
NEUTRALN LLOAD NEUTRALN LLOAD
GROUNDFAULT
CIRCUITINTERRUPTERS
JUNCTION
BOX
AIRSTREME
(HEATEDBACKREST
A&HEADREST)
TURBINEWITHGEYSAIR
(FORMIA®,MIAPLUS®,
MIAMULTI®)
INMIXMODULE
(CHROMATHERAPY)
AROMACLOUDTM
N LN L N LN L
tURbIne WITH GeYsaIRtm
& aRomacloUdtm
ELECTRICAL INSTALLATION

TURBINE
www.bainultra.com
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
Supersedes page 29 of Owner’s Manual 9
TURBINE | TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL
ELECTRICAL DIAGRAM
TURBINE WITHOUT GEYSAIRTM, & WITH AROMACLOUDTM
Electrical connections for Canada only.
15ACIRCUIT
(OR20AIFAMMAw.DOUBLEHEATEDBACKREST)
N LN L N LN L
15ACIRCUIT
NEUTRALN LLOAD NEUTRALN LLOAD
GROUNDFAULT
CIRCUITINTERRUPTERS
JUNCTION
BOX
AIRSTREME
(HEATEDBACKREST
&HEADREST)
TURBINEWITHGEYSAIR
(FORMIA®,MIAPLUS®,
MIAMULTI®)
INMIXMODULE
(CHROMATHERAPY)
AROMACLOUDTM
TURBINE WITHOUT GEYSAIRTM WITH AROMACLOUDTM - ELECTRICAL INSTALLATION
tURbIne WITHOUT GeYsaIRtm
, AND WITH aRomacloUdtm
ELECTRICAL INSTALLATION

TMU & TMSUTM ADDENDUM TO THE OWNER’S MANUAL | TURBINE
1 800 463.2187 From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © January 2013 BainUltra Inc. All rights reserved. 45100572
Some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
10 Supersedes page 28 of Owner’s Manual
• Electrical outlet must be installed by a certified electrician. Installation must be conducted in
accordance with all local, provincial/state, and federal building/electrical codes and regulations.
Connect electrical power supply only after all low voltage wiring is properly installed on turbine.
If you did not follow this last step, shut off and then restart your home’s circuit breaker. Turbine
and air pipe should be clear of building materials and wiring.
WARNING
THERMASENS - ELECTRICAL INSTALLATION
CONNECTIONS FOR DOT CONTROLS ON THERMASENSTM BATHS
theRmasenstm
ELECTRICAL INSTALLATION
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Bañera de BainUltra
Manuales populares de Bañera de otras marcas

Lyons
Lyons Elite ETLxx663219 Series Manual de usuario

Woodbridge
Woodbridge BJ500 Instrucciones de montaje

Whirlpool
Whirlpool Ariel ARL-702 Manual de usuario

TEIKO
TEIKO EXCELLENT DUO Manual de usuario

American Standard
American Standard Colony 5-1/2' x 32" Manual de usuario

American Standard
American Standard 3052OD.X0X Guía de inicio rápido