VESALA PKT2 Manual de usuario

User Manual
Transmitter PKT2 X2.0 ENG
for Vesala PK2 Drill Point Locator Transmitter PKT2 X2.0
IMPORTANT: Read carefully before use.
Keep for future reference.
English
Issued: 2022-03-04
Revised: 2022-05-11

User Manual Vesala Transmitter PKT2 X2.0 ENG
2 (20)
Table of contents
1
Safety notes .......................................................................................................................................................... 3
2
General description ............................................................................................................................................ 5
2.1
Intended use ................................................................................................................................................ 5
2.2
Specifications ............................................................................................................................................... 5
2.3
Package contents ....................................................................................................................................... 8
2.4
PKT2 parts and functions ......................................................................................................................... 9
3
Commissioning ................................................................................................................................................. 10
3.1
Inserting and replacing batteries ....................................................................................................... 10
3.2
Testing correct operation ..................................................................................................................... 11
4
Operating Transmitter PKT2 ......................................................................................................................... 12
4.1
Inspecting the work site for hazards ................................................................................................. 12
4.2
Locating hazards with Transmitter PKT2 ......................................................................................... 12
4.3
Objects that may decrease locating accuracy ................................................................................ 13
4.4
Locating accurately thru thick structures ........................................................................................ 14
4.5
Attaching Transmitter PKT2 to structures ....................................................................................... 14
5
Taking care of your equipment ................................................................................................................... 16
5.1
Storing ........................................................................................................................................................ 16
5.2
Cleaning ..................................................................................................................................................... 16
5.3
Troubleshooting ...................................................................................................................................... 17
5.4
Modifying and misuse ........................................................................................................................... 19
5.5
Warranty ..................................................................................................................................................... 19
5.6
Disposal ...................................................................................................................................................... 19
6
Supplier contact information ....................................................................................................................... 20
7
Declaration of conformity ............................................................................................................................. 20

3 (20)
User Manual Vesala Transmitter PKT2 X2.0 ENG
1 Safety notes
To avoid possible harm, read and follow these instructions.
DANGER: Risk of death, personal injury, or property damage
Attaching the device to an elevated position may be dangerous if the attachment fails. Notice
that moisture, dirt, surface properties, ambient temperature or aging may reduce the reliability
of the supplied adhesive putty or affect the amount of adhesive putty required to reliably attach
the device to a surface. If possible, restrict access to the hazard zone under the device when the
device is attached to an elevated position. Always secure the device with additional supports if
the device is attached to an elevated position, and it is possible that persons or animals may
enter the hazard zone under the device. When the device cannot be reliably secured and the
hazard zone under the device cannot be completely restricted, it is required that anyone
entering the hazard zone under the device wears adequate personal protection equipment.
Always remove the device before drilling.
DANGER: Risk of electric shock, fire, or property damage
Drilling a structure may damage a dangerously live electric cable or a pressurised pipe. Before
drilling a structure, make sure the structure doesn’t contain dangerously live cables or
pressurised pipes. If their existence cannot be excluded, the whole installation containing the
structure should be de-energized and de-pressurised before drilling begins. In some cases, a
decrease in locating accuracy may move the intended drill point.

User Manual Vesala Transmitter PKT2 X2.0 ENG
4 (20)
WARNING: Risk of electric shock, fire, or property damage
When scanning a structure for live cables with the device, notice that the effective range of the
voltage detector is limited, and scanning should be done from both sides of the drilled structure
before drilling begins. Certain materials or structures may block the electric field of a
dangerously live cable and render the voltage detector ineffective. Only cables that are live at
the time of scanning may be detected with the voltage detector.
ATTENTION: Risk of property damage
When scanning a structure for pipes with the device, notice that the effective range of the metal
detector is limited, and scanning should be done from both sides of the drilled structure before
drilling begins. Only metallic pipes may be detected with the metal detector.
ATTENTION: Risk of locating error due to electromagnetic conditions
Large metallic objects, radio transmitters or industrial equipment may degrade locating
accuracy or may prevent locating completely. Before attempting to locate a drill hole, take care
that there are no large metallic objects at or near the intended drill hole. Large metallic objects
include radiators, sheet metal, foil, and wire mesh among other things. Shut down or move any
radio transmitters that actively transmit on the same frequency at least 10 m away from the
intended drill hole. This includes other drill point locators.

5 (20)
User Manual Vesala Transmitter PKT2 X2.0 ENG
ATTENTION: Risk of locating error due to device misorientation
Locating drill points with misoriented devices may degrade locator performance. Instructions
for properly orienting the devices are provided in section 4: Operating Transmitter PKT2.
2 General description
2.1 Intended use
Drill Point Locator Transmitter PKT2 is used to locate positions and measure distances thru non-
conductive structures such as walls, floors, and ceilings before drilling or cutting. A separate
receiver unit is needed to locate the position marked with PKT2: Receiver PKR2 is included in
PK2 Drill Point Locator kit with Transmitter PKT2. In addition to locating, PKT2 unit may be used
to detect metallic objects and power lines inside the structure before drilling or cutting. Drill
Point Locator Transmitter PKT2 is intended for professional use in dry conditions.
2.2 Specifications
Operating temperature,
LR03 batteries installed -10°C…+40°C
Operating temperature,
FR03 batteries installed -20°C…+40°C
Humidity 10…90 % RH, non-condensing

User Manual Vesala Transmitter PKT2 X2.0 ENG
6 (20)
Storage temperature, LR03 batteries installed +5°C…+30°C
Storage temperature, batteries removed or
FR03 batteries installed -20°C…+40°C
Degree of protection IEC 60529 IP40
Batteries 3 pcs 1.5V IEC LR03 or FR03
Current consumption 40…95 mA
Nominal battery voltage 4.5 V
Enclosure material ABS
Enclosure size 176 x 78 x 29 mm
Weight, LR03 batteries included 200 g
Locating range 0…150 cm
Distance indication range 1…200 cm
Performance in free air, room temperature,
≥1000 mm from conductive objects Metal detection depth,
100x100x0.3 mm steel: 30 mm
Power line detection depth, 230 V 50 Hz
single phase, handheld: 150 mm

7 (20)
User Manual Vesala Transmitter PKT2 X2.0 ENG
Operating frequency bands,
maximum power transmitted 0…700 Hz, input
9000…9183 Hz, <100 mW
433.62…434.22 MHz, <-13 dBmW
Electromagnetic environment ETSI EN 301 489-1: Residential, commercial
and light industrial environment
International standards this product is in
conformance with EN 300 220-1
EN 300 220-2
EN 300 330
EN 301 489-1
EN 301 489-3
EN 303 454

User Manual Vesala Transmitter PKT2 X2.0 ENG
8 (20)
2.3 Package contents
PK2 Drill point locator (V11740) contains the following items
Drill Point Locator Receiver PKR2, version X2.0 (V11744)
Drill Point Locator transmitter PKT2, version X2.0 (V11741)
Alkaline battery LR03, 6 pcs (J01573)
Felt pad, 4 pcs (N05925)
Adhesive putty, Casco 2981, 60 g (S14010)
User manuals
Version numbers are indicated at the beginning of the serial number.

9 (20)
User Manual Vesala Transmitter PKT2 X2.0 ENG
2.4 PKT2 parts and functions
Centre hole and cross hair
Position hole centre at the desired point.
Metal detector
Indicates the presence of metal.
Voltage detector
Indicates the presence of live AC voltage.
Power LED
Green LED indicates power on.
LED blinks if batteries should be replaced.
Power and mute button
Long press: Toggle power on or off.
Short press: Toggle speaker mute on or off.
Mute resets to off at start-up.
Speaker
Higher pitch indicates shorter distance to metal or to a live object.
Batteries
Located backside under battery cover: 3 x 1.5 V LR03 or FR03

User Manual Vesala Transmitter PKT2 X2.0 ENG
10 (20)
3 Commissioning
3.1 Inserting and replacing batteries
1. Clean and dry the device with a soft cloth.
2. Gently press battery cover and slide towards bottom end.
3. Remove old batteries.
4. Insert three new 1.5 V LR03 (AAA) alkaline batteries or FR03
lithium batteries. FR03 batteries should be used when
ambient temperature is below -10°C. Observe that battery
polarity matches markings on the battery compartment.
5. Put battery cover back on and gently close it.
Tabla de contenidos
Otros manuales de Transmisor de VESALA

VESALA
VESALA MicroSonde MPL6-33 Manual de usuario

VESALA
VESALA NanoSonde MPL4-33 Manual de usuario

VESALA
VESALA Sonde PL18-05 Manual de usuario

VESALA
VESALA MicroSonde MPL7-33 Manual de usuario

VESALA
VESALA MiniSonde MPL9-33 Manual de usuario

VESALA
VESALA MicroSonde VMS6-33 Manual de usuario

VESALA
VESALA Sonde PL18-33 Manual de usuario
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario