Page 1
CL-B101D40RPM(d0097) manual
• ThismeterhasbeendesignedspecificallyforRPMmeasurements.
JustenterthepulesperrevolutionandtheCL-B01DRPMbargraph
willcalculateanddisplaytheRPMreading.
• Three ranges with resolution of 0.1 RPM, 1 RPM and 10 RPM
(99.99x1000rpmmax).
• Optionalisolated16bitanalogoutput.Userorfactoryscalable
to4to20mA,0to20mAor0to10Vacrossanydesireddigital
spanfrom±onecounttothefullscalerangeof0to9999.
• Standard101segmentRedBarandRed4-digitLEDdisplaywith
arangeof0to9999.OptionalGreenBarandGreenDigitaldis-
play.AlsoOptionalProgrammableTricolor(Red-Green-Orange)
Barisavailable.
• FrontpanelLEDannunciatorsprovideindicationofsetpointstatus.
•
Two 9 Amp Form C, and two 4 Amp Form A or 4 x 4 Amp Form A
relays available
.
• Provisiontoconnectanexternalprogramminglockoutswitch.
• ProvisionforexternalDIMswitchtoreducethebrightest
displaysettingby50%.
• Automaticintelligentaveraging,smoothsnoisysignalswhile
providingafastdisplayresponsetoreallevelchanges.
• 24Vexcitationisavailabletopowerencodersorproxswitches.
General Features
Specifications
Index
Software Features
Bargraph Center Point Display Mode Selection ... 6
Bargraph Color Programming Mode ........ 9
Case Dimensions ....................... 7
Component Layout..................... 10
Connector Pinouts and Pin Descriptions..10-11
Controls and Indicators .................. 2
Setpoint Setting & Relay Configuration Mode....8-9
Software Features ...................... 1
Software Logic Tree ..................... 3
Specifications.......................... 1
Two Point Analog Output Range Calibration ..... 7
Digital Span Selection for Bargraph Display .. 5
Digital Span Selection for Analog Range Output... 6
General Features ....................... 1
I-Series Input Signal Conditioning Modules ..... 11
Ordering Information ................... 13
Programming Conventions................ 2
Input Specs:.................. DependsonInputsignalconditioner
A/D Converter:.............. 14bitsingleslope
Accuracy:...................... ±(0.05%ofreading+2counts)
Temp. Coeff.:................. 100ppm/°C(Typical)
Warm up time:............... 2minutes
Conversion Rate:.......... 10conversionspersecond(Typical)
Digital Display:..............
4 digit 0.56" LED red (std),green(optn)
Range
0to9999counts.
Bargraph Display:.........
101 segment 235º circular bar red (std),
green(optn)ortricolor(optn),
Polarity:......................... Assumedpositive.Displays–negative
Decimal Selection:........ Frontpanelbuttonselectable,X•X•X•X•
Positive Overrange:...... Bargraphandtopsegmentsofdigitaldisplay
flash.
Negative Overrange:.... Firstsegmentofbargraphandbottomseg-
mentsofdigitaldisplayflash.
Relay Output:................ Two9AmpFormCrelays,two4AmpForm
Arelaysor
4 x 4 Amp Form A relays.
Analog Output:............. Isolated16bituserscalablemAorV
OIC(mAout)..............
4-20mA@0to500Ωmaxloopresistance
OIV(voltsout).............. 0-10VDC@500Ωorhigherresistance
Power Supply:............... AC/DCAutosensingwiderangesupply
PS1 (std)....................
85-265 VAC / 95-300 VDC, 50-400Hz 4.2W
PS2.............................
18-48VAC/10-72VDC,50-400Hz4.2W
Operating Temp.:.......... 0to50°C
Storage Temp:............... –20°Cto70°C
Relative Humidity:........ 95%(noncondensing)
Case Dimensions:........
Bezel(4.48"x4.48")113.8x113.8mm
Depthbehindbezel(4.23")107.46mm
Plus(0.48”)12.24mmforconnectors
Weight:........................... 16oz.,1lb4ozwhenpacked
CL-B101D40RPM
Smart 101 segment, 4 digit LED Tricolor or
Mono-color digital bargraph controller
with four fully programmable set points
in a switchboard style case for
RPM Measurement.
0.56”
LEDs
LEOPARD
FAMILY
• Thebargraphcandisplay,full
scale,anydesiredportionof
thedigitalreading.
• Setpoint1hasdelay-on-make
anddelay-on-breakplus
aspecial“pumponpump
off”modethatcreatesa
HysteresisBandbetweenSP1
andSP2.
• Fourprogrammablesetpoints
withadjustableHysteresis.•
Bargraphcenterzerofunction.
• Relayactivationcanbeselect-
edtooccurabove(hi)orbelow
(Lo)eachsetpoint.
• Decimalpointsetting.
• Digitaldisplayblanking.
• Four-levelbrightnesscontrol