Reset
SET of Parameters
In the standby mode , press "SET" for 5 sec, flickers,this is setting for softness / hardness.Again press "SET" for 5 sec , at the top right
corner four figures flickers , it's numbers' of cones , at this state,press " softness" for 5 sec .,numbers of cones become 0 . Again press "SET" for 5
sec .," stop time" flickers which is set for stop time after 99% shape rate. Again press " SET " for 5 sec ., the temp . is for pre-cooling setting.Again
press "SET " for 5 sec ., it's modification valve of lack of raw material. Again press " SET " for 5 sec . , it's delay time for compressor to start. Again
press " SET " for 5 sec . , it's state of air pump . 1 is off . 2 is auto . 3 is on .
Hardness / softness and relative parameter setting
In the state of setting hardness / softness , press " hard " or "soft " can change it . Range is 1-12 . Note : If it's too hard , ice cream will not be
able to put out.
In the setting state of "stop time" , press " hard or " soft " can change length of time . Range is 1-15 , default is 5 min.
In the state of setting temp . of pre-cooling , press " hard " or " soft " can change pre-cooling temperature. Range is from I℃ to 15℃,with
default 10℃.
In the state of setting motor modification valve , press " hard or " soft can change motor modification valve , range is 1-32 , make 16 as a
middle valve , add one number means add one circle base on the actual measurement. Minus one number means decrease one circle base on the
actual measurement . It's been adjusted well at the factory , it's not suggest user change this parameter . If do , pleas consult after-service staff .
In the state of setting temp of lacking raw material, press "hard " or "soft" can change temp of lacking raw material. Range is -2℃—15℃, small
number means increase sensitivity while big number means decrease sensitivity.
In the compressor delay start time setting state , jog " plus " or " minus " key , you can modify the compressor delay start time , the value
range : 1-120 seconds , the factory default is 20 seconds , this parameter is factory set Well users do not make adjustments .
In the puffed pump work set state , jog " plus " or " minus " key , adjustable puff pump state . 1 , often off ; 2 , automatic ;3 , normally open ;
puffer pump factory default is " 2 " automatically , the user in use if the slurry does not go , please puff the pump off .
In the standby mode , press " hard " and " soft " at the same time and hear the beep . . beep . . . After 5 seconds , all parameters are restored to the
factory state.