6
TWO YEAR LIMITED WARRANTY
For a period of two (2) years from date of purchase, SFA Companies will repair or replace, at its option, without
charge, any of its products which fails due to a defect in material or workmanship under normal usage. This limited
warranty is a consumer's exclusive remedy.
Performance of any obligation under this warranty may be obtained by returning the warranted product,
freight prepaid, to SFA Companies Warranty Service Department, 10939 N. Pomona Ave., Kansas City, MO 64153.
Except where such limitations and exclusions are specically prohibited by applicable law,
(1) THE CONSUMER'S SOLE AND EXCLUSIVE REMEDY SHALL BE THE REPAIR OR REPLACEMENT OF
DEFECTIVE PRODUCTS AS DESCRIBED ABOVE.
(2) SFA Companies SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGE OR LOSS
WHATSOEVER.
(3) ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED TO ONE YEAR,
OTHERWISE THE REPAIR, REPLACEMENT OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED
WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
(4) ANY MODIFICATION, ALTERATION, ABUSE, UNAUTHORIZED SERVICE OR ORNAMENTAL DESIGN VOIDS
THIS WARRANTY AND IS NOT COVERED BY THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may
not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This warranty gives you specic legal rights, and you may
also have other rights, which vary from state to state.
SFA Companies
10939 N. Pomona Ave. Kansas City, MO 64153
816-891-6390
TROUBLESHOOTING
Symptom Possible Causes Corrective Action
Jack will not lift load • Release valve not tightly closed
• Load is too heavy
• Ensure release valve tightly closed
• Consider higher capacity jack
Jack will lift, but not maintain
pressure
•Release valve not tightly closed
• Hydraulic unit malfunction
•Ensure release valve tightly closed
• Discontinue use, contact technical
service
Jack will not lower after unloading
• Reservoir overlled
• Linkages binding
• Fluid level low
• Drain uid to proper level
• Clean and lubricate moving parts
• Ensure proper uid level
Poor lift performance
• Fluid level low
•Air trapped in system
• Ensure proper uid level
•Follow Bleeding/Venting Trapped
Air procedure (page 3)
Will not lift to full extension • Fluid level low • Ensure proper uid level