Sensorex TX3000 Manual de usuario

PRODUCT INSTRUCTION MANUAL
TX3000 - pH/mV
Transmitter/Controller
Form: INSTRTX3000-Rev A

Form: INSTRTX3000-Rev A
PRODUCT INSTRUCTION MANUAL

Thank you for choosing the TX3000 pH/mV transmitter. This transmitter is a user-friendly microprocessor based trans-
mitter for pH and mV measurement. As with all electronic instruments, it is essential to follow all directions for optimal
performance. In particular, you must properly install, use and maintain the TX3000 to ensure that it will continue to
operate within its specications.
• Follow all warnings, cautions and instructions marked on and supplied with the transmitter. Please contact Sensorex
with any product questions or concerns.
• Install the transmitter as specied in this manual, following all applicable local and national codes.
• Do not attempt to repair your TX3000 transmitter or use any replacement parts from any other supplier.
• If you nd any errors in this manual, please report them to Sensorex.
• Please complete the WARRANTY REGISTRATION located at the back of this manual and fax or e-mail to Sensorex at
fax: 714-894-4839, e-mail: [email protected]
TX3000 pH/mV Transmitter ESSENTIAL INSTRUCTIONS
READ THIS BEFORE USING YOUR TX3000 pH/mV TRANSMITTER!
About This Document
This manual contains instructions for the installation, operation and care of the TX3000 pH/mV transmitter.
The following list provides notes concerning revisions of this document.
Rev Level Date Notes
A 9/2012 1st revision of manual.
Form: INSTRTX3000-Rev A
PRODUCT INSTRUCTION MANUAL

Table of Contents
1. Specications 1
2. Precautions for installation 2
3. Assembly and installation
3.1 Transmitter installation 2
3.2 Cable set-up 3
4. Overview of TX3000 pH/ORP transmitter
4.1 Illustration of rear panel 4
4.2 Illustration of terminal function 5
5. Conguration
5.1 Illustration of front panel 6
5.2 Function Key Description 7
5.3 LED indicators 8
5.4 Display icons 9
6. Operation
6.1 Measurement mode 10
6.2 Set-up mode 10
6.3 Calibration mode 10
6.4 Reset 10
6.4.1 Master reset 10
6.4.2 Calibration reset 10
7. Settings
7.1 Entry into set-up mode 11
7.2 Security code settings 11
7.3 Measurement parameters 12
7.4 Temperature Settings 13
7.5 Stand by Mode 14
7.6 Hi Alarm Relay 15
7.7 Lo point Alarm Relay 16
7.8 Wash time Relay 17
7.9 Analog output 1 (pH/ORP) 18
7.10 Analog output 2 (temperature) 19
7.11 Sample average of measurements (Digital Filter) 20
7.12 Backlit LCD 21
8. Calibration
8.1 Security code of calibration 22
8.1.2 Setting Code 22
8.2 Entry of calibration mode 22
8.3 Any Buer calibration (2-point) 23
8.4 Calibration of pre-set TECH. buer (Ct1) 24
8.5 Calibration of pre-set NIST. buer (Cn1) 26
Form: INSTRTX3000-Rev A
PRODUCT INSTRUCTION MANUAL

Table of Contents
8. Calibration (cont)
8.6 ORP calibration 26
9 Error messages (Error code) 27
10. Warranty
10.1 Warranty 28
10.2 Return of Product 28
Warranty Registration 29
Warranty Terms and Conditions 29
Form: INSTRTX3000-Rev A
PRODUCT INSTRUCTION MANUAL

Figure 3-1 Panel Mount Cut Out 2
Figure 3-2 Wall Mounting 3
Figure 3-3 Coaxial Cable Preparation 3
Figure 4-1 Rear Panel Illustration 4
Figure 4-2 Terminal Functions 5
Figure 5-1 Front Panel 6
Figure 5-2 Displaty Icons 9
Figure 7-1 Security Settings 11
Figure 7-2 Measurement Parameters 12
Figure 7-3 Temperature Settings 13
Figure 7-4 Standby Mode 14
Figure 7-5 HI Alarm 15
Figure 7-6 LO Alarm 16
Figure 7-7 Wash Alarm 17
Figure 7-8 Analog Output 1, 4-20mA (pH/ORP) 18
Figure 7-9 Analog Output 2, 4-20mA (Temperature) 19
Figure 7-10 Sample Averaging 20
Figure 7-11 LCD Backlight 21
Figure 8-1 Entering Calibration Mode 22
Figure 8-2 2-Point Calibration Mode 23
Figure 8-3 2-Point Calibration Mode Ct1 (Preset buers) 24
Figure 8-4 ORP Calibration 26
Figure 9-1 Troubleshooting Chart 27
Form: INSTRTX3000-Rev A
Table of Contents
PRODUCT INSTRUCTION MANUAL

Part 1 Specications
Page 1 of 29
Measuring Range (pH) -2.00 to 16.00pH, 0.01 pH resolution,
+/- 0.01 accuracy, +/- 1 digit
Measuring Range (ORP/mV) -1999mV to +1999mV, 1mV resolution,
+/- 1mV accuracy, +/- 1 digit
Measuring Temperature Range -30 to 130° C, 0.1° C resolution,
+/- 0.2° C accuracy +/- 1 digit
Calibration Mode Any Tech or NIST buers up to 2 points
Analog Output 1 Isolated DC 0/4-20mA corresponding to pH or ORP,
maximum load 500Ω
Analog Output 2 Isolated DC 0/4-20mA corresponding to temperature,
maximum load 500Ω
Display Large LCD display with environment light sensor auto/manual
illumination function
Weight approx. 1.75lb (0.8kg)
Dimensions 5.7"(144mm) x 5.7"(144mm) x 4.5"(115mm)
Mounting Options Wall mount, panel mount, pipe mount
Panel Cut Out Dimensions 5.4"(138mm) x 5.4"(138mm)
Relays 1(HI) - Contact 110,240 VAC, 0.5A Max - programmable ON/OFF
2(LO) - Contact 110,240 VAC, 0.5A Max - programmable ON/OFF
WASH - Contact 110,240 VAC, 0.5A Max - programmable ON (0-9999 sec),
OFF (0-999.9 hrs)
Ambient/Storage Temperature 0-50° C / -20-70° C
Temperature Compensation NTC 30K Ω or 2-wire Pt1000 RTD auto, manual
Power Requirement 100-240 VAC, 50/60 Hz, software selectable
Voltage Output DC +/-12V(to power external transmitter, if required)
Certication IP 65 (NEMA 4X), CE
Form: INSTRTX3000-Rev A
PRODUCT INSTRUCTION MANUAL

pH / ORP Transmitter TX-3000
(144mm)
5.67”
(144mm)
5.67”
(125mm)
4.92”
(98mm)
3.74”
Cord grip x3
Panel mount
ttings x4
90mm
80mm o6
Front View Side View
(127mm)
5.00”
(122mm)
4.80”
Back View
Mounting
hole for M5
Screw (x 4)
TX3000 Specications - Dimensional Specs
PRODUCT INSTRUCTION MANUAL
Part 1 Specications (cont.)

PRODUCT INSTRUCTION MANUAL
Page 2 of 29
Wrong wiring will lead to breakdown or electrical shock of thetransmitter, please read this operation man-
ual clearly before installation.
• Make sure to remove AC power from the transmitter before wiring input and output connections and
before opening the transmitter housing.
• Install the transmitter in a well ventilated area. Avoid installing in areas receiving direct sunshine.
• The material of signal cable should be special coaxial cable. Strongly recommend using our coaxial
cable. Do not use normal wires instead.
• Avoid electrical surge when using power, especially when using three-phase power, use ground wire
correctly.
• The internal relay contact of the transmitter is for alarm or control function. You must connect to an
external relay which can withstand enough current to ensure safe operation of the transmitter. Please
refer to chapter 4.2“Terminal Functions”
Part 2 Installation Precautions
Part 3 Assembly and Installation
3.1 Transmitter installation: This transmitter can be installed by panel mounting, wall mounting and pipe
mounting.
Panel Mounting: Cut a square hole of 5.4"(138mm) x 5.4"(138mm) on the panel, and then insert the trans-
mitter directly into the panel. Attach the mounting bracket from the rear, so that it attaches to groove.
FIG 3-1
Form: INSTRTX3000-Rev A
Side View with
mounting brackets
Mounting
Bracket
4x
Panel
Panel Cutout
5.4"(138mm)
5.4"(138mm)
minimum distance between
TX3000 panel cutouts = 1.7"(42mm)

PRODUCT INSTRUCTION MANUAL
Page 3 of 29
FIG 3-2
Wall Mounting: Use 4 each M5 screws to attached to mounting holes shown below.
FIG 3-3
clear cover
black noise
reduction
layer
clear cover
black noise
reduction
layer removed
3.2 Coaxial Cable Preparation: Cut coaxial cable plastic jacket o. This will reveal the braided shield wire.
Twist the braid together to reveal black noise reducing layer. Remove the black noise reducing layer even
to the braid (See Fig 3-3). Cut some of clear layer away to expose copper center core.
Part 3 Assembly and Installation (cont.)
Form: INSTRTX3000-Rev A
Wall Mounting
Tabla de contenidos
Otros manuales de Transmisor de Sensorex

Sensorex
Sensorex CX105 Manual de usuario

Sensorex
Sensorex TX2000 Manual de usuario

Sensorex
Sensorex TX3100 Manual de usuario

Sensorex
Sensorex CX100 Manual de usuario

Sensorex
Sensorex TX2000 Manual de usuario

Sensorex
Sensorex CT-1000 Manual de usuario

Sensorex
Sensorex TX105 Manual de usuario

Sensorex
Sensorex TX2000 Manual de usuario

Sensorex
Sensorex TX100 Hoja de especificaciones
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario