Rointe SMART Touch Guía de inicio rápido

SMART Touch
EASY SETUP GUIDE
calefacción
heating
chauffage
aquecimento
calefacción
heating
chauffage
aquecimento
EN

SMART Touch
2
INTRODUCTION
This thermostat is designed to aid in the comfort of your home by providing timed regulation of your heating system. The
thermostat is designed to receive temperature input signals from the following sensors:
1. Air sensor located inside thermostat
2. Floor sensor installed in oor if using underoor heating (see heater instructions for details)
The thermostat is not a safety device. In order to avoid damaging your system the correct system and oor type should be
selected during the thermostat programming process.
WARNING – Important safety note
This product uses mains voltage electricity and work should only be carried out by a qualied electrician. You should always
isolate the power supply before attempting to install or repair the thermostat. The thermostat should not be put into operation
unless you are certain that the entire heating installation complies with current general safety requirements for electrical
installations. Electrical installation to be in accordance with latest Wiring Regulations.
LOCATION
The thermostat should be installed inside a single gang electrical wall box that is at least 35mm deep. For optimal performance
the thermostat should be located in an area with good ventilation. It should not be beside a window/door, in direct sunlight or
above another heat generating device (e.g. radiator or TV). The thermostat is designed for operation between 0°C and 55°C with
relative humidity less than 80%.
EN
This is an Easy Setup guide. For full instructions please visit rointe.co.uk / rointe.ie.

2 3
EN
INSTALLATION
Separate the front housing of thermostat from wall module:
1. Unscrew both closing screws (bottom of thermostat) until they will not turn any further
2. Release front housing by gripping lower half of outer frame and pulling outwards then upwards
3. Place front housing somewhere safe
4. Run all wires to the wall box. Check to ensure that you have included the following:
Power (Live and Neutral)
Heater (Live and Neutral or Switch Live only)
Floor sensor
Fil pilote (if necessary)
5. Pull wires through wall box and complete terminal wiring
IMPORTANT: Ensure that multi stranded wires are fully inserted into the terminals and secured tightly. Any loose strands should
be trimmed as they could cause a short-circuit. If connecting more than two heaters, an electrical junction box will be required.
NOTE: Always ensure that the sensor cable is installed in a separate conduit to the power cables supplying the thermostat and
heating system.
ELECTRICAL SPECIFICATION:
• Supply voltage: 230V +/-10% at 50Hz
• Thermostat is not designed for use with intermittent power supply.
• Maximum Switch Load: 16A resistive
• Insulation Class: II
• IP33
• Standards: EN60730-1 & EN60730-2-9
NOTE: This product is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive
1999/5/EC. The Declaration of Conformity may be consulted by visiting: https://rointe.eu/documentos/Declaration-of-conformity.pdf

SMART Touch
4
ELECTRIC UNDERFLOOR INSTALLATION
see numbering on diagram
2. Connect to Power Supply (Live – MAX 230V)
3. Connect to Power Supply (Neutral – MAX 230V)
4. Connect to heater(s) (Neutral – MAX 3600W/16
Amps)
5. Connect to heater(s) (Live – MAX 3600W/16 Amps)
7. Connect to 1st wire of oor sensor (colour not
important)
8. Connect to 2nd wire of oor sensor (colour not
important)
HYDRONIC UNDERFLOOR INSTALLATION
see numbering on diagram
2. Connect to Power Supply (Live – MAX 230V)
3. Connect to Power Supply (Neutral – MAX 230V)
4. Connect to wiring centre (Neutral if present – MAX
3600W/16 Amps)
5. Connect to wiring centre (Switch Live – MAX 3600W/16
Amps)
7. Connect to 1st wire of oor sensor (colour not important)
8. Connect to 2nd wire of oor sensor (colour not important)
33
EN

4 5
EN
CENTRAL HEATING INSTALLATION
see numbering on diagram
2. Connect to Power Supply (Live – MAX 230V)
3. Connect to Power Supply (Neutral – MAX 230V)
4. Connect to Boiler circuit (Neutral if present– MAX
3600W/16 Amps)
5. Connect to Boiler circuit (240V Switch Live – MAX
3600W/16 Amps)
For extra low voltage or volt-free systems a contactor must
be used.
Connecting the thermostat directly to extra low voltage or
volt-free boilers may cause damage to the boiler circuit.
MOUNTING THERMOSTAT
1. Push excess wire back through the wall box and
insert thermostat back module into wall box
2. Put xing screws through mounting holes and
tighten
3. Ensure that thermostat is straight before tightening
completely
4. Replace thermostat front housing;
i) align and sit front housing on to hinges,
ii) push lower half of front housing until a
‘click’ is heard.
5. Ensure front housing is securely xed
6. IMPORTANT: Tighten both retaining screws
SPECIAL INSTALLATION
see numbering on diagram
Master/Relay installation: (connecting 2 thermostats together)
6. Connect to terminal 6 on other thermostat
7. Connect to terminal 7 on other thermostat

SMART Touch
6
POWERING UP
You can now power up the thermostat and begin the programming process. An easy to follow menu will guide you through the
rest.
ERROR MESSAGES
Your thermostat can give you two error indications:
1. “er1”: This will occur if no oor sensor is detected
2. “er2”: This will occur if the oor sensor has a short circuit
CONNECT TO SMART.ROINTECONNECT.COM
Once your thermostat is powered up, you need to create your account. Navigate your web browser to smart.rointeconnect.com.
Enter your email address and create a password for your account. You will be sent a conrmation email when your account is set
up. Make sure you check your spam folder as well as your inbox.
When you’ve received your account activation email, you can connect your thermostat to the account. Ensure your thermostat
is connected to the internet. If you see an error icon on the homescreen like below, then your thermostat is not connected to the
internet. If you can’t connect to the internet, you can skip this stage and connect any time in the future.
When your thermostat is connected to the internet, just enter the unique code displayed on the connection screen into your
account. Your thermostat will then be connected.
If you see these icons, call for assistanceNo WiFi ConnectionNot connected to Server
EN

6 7
EN
WARRANTY
Rointe warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of
two (2) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be
defective, Rointe shall repair or replace it, at Rointe’s discretion.
If the product is defective, please either,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
(ii) contact Rointe. Rointe will determine whether the product should be returned, or replaced.
This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Rointe that the defect or
malfunction was caused by damage which occurred while the product was in the possession of the end user.
Rointe’s sole responsibility shall be to repair or replace the product within the terms stated above.
ROINTE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESSED OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS
WARRANTY ROINTE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE TWO-
YEAR DURATION OF THIS WARRANTY.
This Warranty does not affect your statutory rights.
Please register your product at: www.rointe.co.uk / www.rointe.ie

SMART Touch
8
NOTES

8 9
SMART Touch
FR
calefacción
heating
chauffage
aquecimento
calefacción
heating
chauffage
aquecimento

SMART Touch
10
FR
INTRODUCTION
Le thermostat a été conçu an d’améliorer le confort dans votre habitation en apportant une régulation programmée de votre
système de chauffage. Le thermostat reçoit des signaux électriques provenant des sondes suivantes:
1. Une sonde d’air est fournie avec le thermostat
2. Une sonde de sol sera fournie pour le plancher chauffant.
Un thermostat n’est pas hors de danger. An d’éviter d’endommager votre système, il vous faudra sélectionner le bon système
de chauffage et type de revêtement lors du processus de programmation.
ATTENTION – Mesure de sécurité!
Ce produit utilise un fort voltage électrique et ne doit être branché que par un électricien qualié. Vous devez toujours isoler
l’alimentation électrique avant d’essayer d’installer ou de réparer le thermostat. Le thermostat ne doit être utilisé qu’une fois que
vous êtes certain que tout le système de chauffage a été installé dans le respect de toutes les normes de sécurité électrique: NF
C 15-100 et avis technique du CSTB.
LOCATION
Le thermostat doit être installé dans une boîte murale enfoncée d’au moins 35mm dans le mur. Pour une meilleure performance,
le thermostat doit être installé dans une zone bien ventilée. Il doit être éloigné des fenêtres, portes etc... Et ne doit pas être installé
dans un endroit où il reçoit directement le soleil ou une forte chaleur ; par exemple celle produite par des appareils électriques tel
qu’un téléviseur. Le thermostat a été conçu pour une température entre 0°C and 55°C à moins de 80% d’humidité
Il s’agit d’un guide d’installation facile. Pour obtenir des instructions complètes, veuillez visiter
rointe.fr
Tabla de contenidos
Idiomas:
Otros manuales de Termostato de Rointe
Manuales populares de Termostato de otras marcas

EWELLY
EWELLY EW-181 Manual de usuario

Prolon
Prolon T1100 Instrucciones de instalación

Computherm
Computherm Q20 Manual de usuario

Heatmiser
Heatmiser neoStat Manual de usuario

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manual de usuario

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manual de usuario