Rinnai BC-100V1Z Guía de inicio rápido

INFINITY Kitchen and Bathroom Deluxe controllers
Operation and installation guide
Your guide on how to use and install Rinnai Deluxe water controllers
This guide is for the use and installation of Rinnai Deluxe water controllers, models
MC-100V1Z and BC-100V1Z.
These instructions must be used in conjunction with the Rinnai water heater operation
and installation guides.
The Deluxe water controllers are compatible ONLY with the Rinnai water heaters shown
on p. 4.
To confirm the maximum number and combination of controllers that can be fitted to
your Rinnai INFINITY refer p. 5.
Bath

Rinnai INFINITY water controllers must be installed in
accordance with:
-Manufacturer’s installation instructions
Current:
-AS/NZS 5601 Gas Installations
-AS/NZS 3000 Electrical Standards
-AS/NZS 3500 Plumbing and Drainage Standards
Installation, servicing and repair shall be carried out only by
authorised personnel.
Warning
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or
loss of life.
For more information about buying, using, and servicing of
Rinnai appliances call: 0800 RINNAI (0800 746 624).
Rinnai New Zealand Limited
105 Pavilion Drive, Mangere, Auckland
PO Box 53177, Auckland Airport, Auckland 2150
Phone: (09) 257 3800
Email: [email protected]
Web: www.rinnai.co.nz
www.youtube.com/rinnainz
www.facebook.com/rinnainz
Important

Warning about hot water ......................................4
Water controller congurations.............................4
Water temperature control....................................5
General controller information ..............................6
Kitchen Deluxe controller operation......................8
Bathroom Deluxe controller operation..................10
Water controller installation ..................................13
A26 controller communication cables...................16
EF26 controller communication cables.................17
N-Series controller communication cables ...........18
Contents

4 | Rinnai INFINITY Deluxe controller OIM 01-20
Warning about hot water
Excessively hot water is dangerous. Rinnai INFINITY continuous ow water heaters, through the
use of water controllers, allow you to control the temperature of hot water to safe levels.
DANGER BEWARE OF
SCALDING HAZARDS
HOT!
HOT!
Always
• Test the water temperature with your elbow before placing
your child in the bath, and feel the water yourself before
bathing or showering.
• Supervise children whenever they are in the bathroom.
• Make sure the hot water tap is turned o.
Consider
Installing child proof tap covers or child resistant taps, both will
prevent a child being able to turn on a tap.
Never
Leave a toddler in the care of another child. They may not
understand the need to have the water temperature set at a safe
level.
Water controller compatibility
The deluxe controllers are compatible with the current range of Rinnai INFINITY models, these are:
• Rinnai INFINITY A-Series
• Rinnai INFINITY EF26
• Rinnai INFINITY HD
• Rinnai INFINITY N-Series
For compatibility with older superseded models, please refer to the deluxe controller product page
on the website www.rinnai.co.nz.
Important
• Controllers cannot be installed in solar or other applications where the Rinnai INFINITY dip
switch setting is increased to above 65 °C
• Controllers cannot be installed in ring main applications using the N-Series
• The Bathroom Deluxe controller bath ll function will not work in applications where HD units
have been connected together with an EZ Connect cable

Rinnai INFINITY Deluxe controller OIM 01-20 | 5
Water temperature control
Controllers allow precise temperature control by the user. When used correctly, the hot water unit
will deliver the selected water temperature, even when the water ow is varied, or when more than
one tap is in use.
Only the Kitchen Deluxe controller can be designated as the master water controller, typically,
as the name suggests, the location for this is in the kitchen. All the remaining controllers are
designated sub-controllers and are for use in bathrooms, toilets, and laundries. The maximum
temperature for sub-controllers is 50 °C, to minimise the risk of burns.
Any controller that has priority is capable of setting the water temperature to be delivered. Priority
can only be given to one controller at a time, and changing priority can only be done when all hot
water taps have been closed.
Available controller temperatures are:
Controller Temperature °C
Kitchen 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55, 60*, 65*, 75*
Bathroom (hot water) 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50
Bathroom (bath ll) 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48
* Some Rinnai water heaters can be programmed to deliver higher temperatures from the master
water controllers, i.e. in commercial applications
To obtain water temperatures lower than 37 °C, open the cold water tap and add cold water until
the desired lower temperature is reached.
The hot water temperature is constantly monitored by a built-in sensor. If the hot water temperature
rises to more than 3 °C above the selected temperature, the burner will automatically go out. The
in-use indicator on the controller display will also go out. The burner will ignite again once the
outgoing hot water temperature reaches the temperature set on the controller.
Water controller congurations
A maximum of four (three for the N-Series) water controllers can be tted, with the following
provisos:
• Only ONE master controller can be installed. This can be a MC-100V1Z or a MC-601
(Universal controller). If a MC-100V1Z is tted it will always function as a master controller.
• Up to a maximum of two Bathroom Deluxe controllers can be installed.
• The fourth controller in any installation MUST BE a MC-601 Universal controller (not applicable
for the N-Series).

6 | Rinnai INFINITY Deluxe controller OIM 01-20
General controller information
S
O
L
V
E
N
T
Bath Bath Bath
Max. 43 ºC
Cleaning
To clean your controller, use a soft damp
cloth and mild detergent.
DO NOT use solvents.
Maximum temperature
While hot water outlets are open the set
temperature may be lowered, but not
raised above 43 °C, and transfer between
controllers is not possible. These are safety
features.
50 ºC
49 ºC
Bath
Temperature variation
Depending on weather conditions and the
length of pipe between the Rinnai INFINITY
and the outlet in use, there may be a
variation between the temperature displayed
at the water controller and at the water
outlet.
No need to turn o
There is no need to turn the controller o
after use.
BathBath
Kitchen Bathroom Kitchen
Bath
Kitchen default 50 °C
As a safety precaution, if a kitchen controller
temperature is set above 50 °C, transferring
and then returning priority will result in a
default set temperature of 50 °C. This is a
safety feature.
Do not press On / O when in use
Do not push the On / O button when the red
water heater In Use indicator is on. This will
turn o the water heater causing the water to
go cold.

Rinnai INFINITY Deluxe controller OIM 01-20 | 7
55 °C maximum
Temperatures higher than 55 °C should not
be able to be selected on controllers installed
in bathrooms, ensuites, or toilets. This is to
reduce the risk of burns from hot water. If this
is not the case, the controllers have been
incorrectly installed and you should contact
your installer.
Always check before use
Check the water temperature before use.
A parent or carer should ALWAYS check
the temperature before a child is placed in
contact with hot water.
Controllers need to be turned on for delivery of hot water
The water heater will not heat the water unless the controller(s) are turned on. If water is owing
before the controller is turned on, the water heater will not heat the water. Turn o the tap for a few
seconds, then turn on again.
Ignition problems
If the water heater fails to ignite, the In Use button will not illuminate. The water heater will not
attempt re-ignition until water ow is stopped for a few seconds and then re-started.
When gas bottles have been changed or the gas supply is disrupted (controller may display error
code 11 or 12) ignition may fail and the In Use button will not illuminate. The water ow may need
to be stopped and re-started several times to get the water heater to work.
Bath
Avoid water in the speaker
Avoid getting water directly into the speaker
(circled in images above) as this may cause
damage.

8 | Rinnai INFINITY Deluxe controller OIM 01-20
Kitchen Deluxe controller operation (MC-100V1Z)
Bath
Shower saver / bath ll
Indicates the shower saver / bath
ll function is operating
Water temperature indicator
Indicates the selected hot water
temperature
In use indicator
Indicates the water heater is in
operation and delivering hot water
Clock
12-hour AM / PM clock display.
In the event of a fault error codes
will ash here.
Speaker
Digital monitor
Up and down buttons
When in ‘normal’ mode these
are used to select the water
temperature.
In setup mode these buttons are
used to adjust the voice prompt
volume and to set the clock.
Mode
Used to switch the controller
between normal, voice, or clock
modes.
Transfer
Used to transfer priority between
the controllers. The controller with
priority has command of the hot
water delivery temperature. This
button is illuminated when the
controller has priority.
On / O
Used to switch the water heater
on and o. Button is illuminated
when the controller has priority.
Turning on
If the controller is switched o (no digits displayed in the digital monitor), press the On/O button
once. The On/O and Transfer buttons illuminate to indicate that the hot water unit will be ready to
supply hot water once a hot water tap is opened.
Adjusting the temperature
Select the desired temperature using the up or down buttons until the required temperature is
displayed.
To operate the hot water unit, open any hot water tap. This will automatically light the burner
providing hot water. The water heater In Use indicator will illuminate on the controller.
Once the hot water is running, if the set temperature is either too hot or cold, press the up or down
buttons until the desired temperature is reached.
While hot water outlets are open, the set temperature may be lowered, but it can’t be raised
above 43 °C. In addition, transfer of priority between controllers is not possible. These are
safety features.
Transferring priority
To control the water delivery temperatures when using two or more controllers transfer the priority
to the controller you wish to use.
Illuminated On/O and Transfer buttons conrm that the desired controller is in control of the water
delivery temperature. If the On/O button is not illuminated, press the Transfer button once, the
On/O and Transfer buttons will illuminate indicating that the hot water temperature control has
been transferred and that the hot water unit will be ready to supply hot water once a hot water tap
is opened.
IMPORTANT

Rinnai INFINITY Deluxe controller OIM 01-20 | 9
Setting the sound options
To set the sound options, press the Mode button once to place the controller into ‘voice’ mode. Use
the up and down buttons to select one of the desired audible settings as follows:
• High
• Medium
• Low
• O (sound o mutes all voice prompts and audible tones)
Press the Mode button twice to return to normal operation. If no buttons are pressed for
approximately ten seconds the controller will return to normal operation.
Setting the clock
The clock is a 12-hour AM/PM style display.
To set the time, press the Mode button twice, this places the controller into ‘clock setting’ mode and
in the digital display the word Clock will be displayed and the clock digits will ash.
Use the up or down buttons to select the time, holding these buttons down continuously cycles the
digits. When you get close to the time you wish to set, press the button intermittently to avoid going
further than the desired time.
To return to normal operation, press the Mode button once. If no buttons are pressed for
approximately 60 seconds the controller will return to normal operation.
The time is always displayed regardless of whether the controller is turned on or o.
The clock may need resetting if power to the water heater is disrupted due to a power failure or if
the power is switched o over a prolonged period. The default time is set to AM 12:00.

10 | Rinnai INFINITY Deluxe controller OIM 01-20
Bathroom Deluxe controller operation (BC-100V1Z)
Shower saver / bath ll
Indicates the bathll / shower saver function is
operating
Water temperature indicator
Indicates the selected hot water temperature
Water level indicator
Indicates bathll / shower saver volume
selected
In use indicator
Indicates the water heater is in operation and
delivering hot water
Transfer
Used to transfer
priority between
the controllers. The
controller with priority
has command of the
hot water delivery
temperature. This
button is illuminated
when the controller
has priority.
Clock and remaining
water volume
indicator
12-hour AM/PM clock
display.
Indicates how much
water remains to
ow for the selected
shower saver / bath
ll—decreases while
the bath lls / shower
runs.
Up and down buttons
When in ‘normal’ mode these
are used to select the water
temperature.
In setup mode these buttons are
used to adjust the voice prompt
volume and to set the clock.
Shower saver / bath
ll button
Illuminates when
selected
On / O
Used to switch the
water heater on
and o. Button is
illuminated when the
controller has priority.
Clock
Used to select clock
setting mode
Water volume selection
Used to select shower saver / bath ll volume
Sound volume button
Used to select the voice and audible tone
options
Turning on
If the controller is switched o (no digits displayed in the digital monitor), press the On/O button
once. The On/O and Transfer buttons illuminate to indicate that the hot water unit will be ready to
supply hot water once a hot water tap is opened.
Adjusting the temperature
Select the desired temperature using the up or down buttons until the required temperature is
displayed.
To operate the hot water unit, open any hot water tap. This will automatically light the burner
providing hot water. The water heater In Use indicator will illuminate on the controller.
Once the hot water is running, if the set temperature is either too hot or cold, press the up or down
buttons until the desired temperature is reached.
While hot water outlets are open, the set temperature may be lowered, but it can’t be raised above
43 °C. In addition, transfer of priority between controllers is not possible. These are safety features.
Transferring priority
To control the water delivery temperatures when using two or more controllers transfer the priority
to the controller you wish to use.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Controladores de Rinnai

Rinnai
Rinnai CNTRLDRCIZHAW Guía rápida

Rinnai
Rinnai MC-601 Instrucciones de instalación

Rinnai
Rinnai MC-100V Hoja de especificaciones

Rinnai
Rinnai MC-601Q Manual de usuario

Rinnai
Rinnai Demand Duo Manual de usuario

Rinnai
Rinnai RS100 Guía de solución de problemas

Rinnai
Rinnai MC502S Manual de usuario

Rinnai
Rinnai MC-601-W Manual de usuario

Rinnai
Rinnai MC-100V Manual de usuario

Rinnai
Rinnai BRIVIS Touch Manual de usuario