Oxgard MODELK-14 Manual de usuario

VOZROZHDENIE LLC
OKPD 27.90.40.190
ТУ 27.90.40-001-33120038-2018
APPROVED BY
ВЗР.248100.000LU
GATE
MODELK-14
ВЗР.248100.000OM
OPERATION MANUAL
32 sheets
2020

ВЗР.248100.000OM
Gate K-14
Operation Manual
2
CONTENTS
1Description and operation.............................................................................................................. 4
1.1 Product description and operation.......................................................................................... 4
1.2 Product indication panel......................................................................................................... 8
2Intended use.................................................................................................................................... 9
2.1 Operating limits ...................................................................................................................... 9
2.2 Preparing the product for use............................................................................................... 10
2.3 Product operation................................................................................................................. 13
2.4 Emergency procedures ........................................................................................................ 14
3Maintenance.................................................................................................................................. 16
3.1 General Provisions............................................................................................................... 16
3.2 Safety precautions................................................................................................................ 16
3.3 Product maintenance procedure........................................................................................... 17
3.4 Visual inspection of the product............................................................................................ 17
3.5 Checking the product components ....................................................................................... 17
3.6 Product functional check ...................................................................................................... 17
4Routine repairs.............................................................................................................................. 19
4.1 Routine repairs of the product .............................................................................................. 19
4.2 Routine repairs of the product components.......................................................................... 19
4.3 Malfunctions during warranty period..................................................................................... 19
5Storage .......................................................................................................................................... 20
6Transportation............................................................................................................................... 21
7Disposal......................................................................................................................................... 22
APPENDIX A —Distributors and service centers ............................................................................. 23
Abbreviations....................................................................................................................................... 29

ВЗР.248100.000OM
Gate K-14
Operation Manual
3
This Operation Manual (OM) applies to Oxgard gate K-14 and its
modifications (hereinafter referred to as the product).
The manufacturer reserves the right to change configuration, technical
characteristics and appearance of the product without further notice.
Before using the product, please read ВЗР.248100.000 Logbook (LB) as
well.
This OM is a document certifying the product’s basic parameters and
characteristics guaranteed by the manufacturer.
The Operation Manual is intended to instruct the user on the principle of
operation, structure of the product to correctly operate the product, fully utilize its
technical capabilities and maintain its constant readiness for operation.

ВЗР.248100.000OM
Gate K-14
Operation Manual
4
1 DESCRIPTION AND OPERATION
1.1 Product description and operation
Gate Oxgard K-14 motorized is designed to control access and1.1.1
manage people traffic.
The product can be used at checkpoints of enterprises, organizations and
banks, in educational institutions, sports and entertainment facilities, shops,
terminal stations and other institutions.
The structural components of the product are detailed in Table 1.1.1.2
Table 1 –Product components
Product designation
Product name
Quantity
Note
Gate
K-14
1
Control panel (CP)
Universal control panel
Praktika
1
Power supply source*
the ACS and OPS cables
Barrier section set*
Praktika barrier
Note - Product components marked with (*) are optional.

ВЗР.248100.000OM
Gate K-14
Operation Manual
5
The product specifications are given in Table 2.1.1.3
Table 2 –Product specifications
Parameter
Value
Overall dimensions of the gate with glass (W×H×L)
depending on the passage-way width, mm:
- 600 mm
- 800 mm
- 900 mm
- 1000 mm
- 1200 mm
800х1140х264
1000х1140х264
1100х1140х264
1200х1140х264
1400х1140х264
Overall dimensions of the gate with a metal tube flap
(W×H×L) depending on the passage-way width, mm:
- 600 mm
- 900 mm
- 1000 mm
- 1200 mm
810х1140х264
1110х1140х264
1210х1140х264
1410х1140х264
Weight of the gate with glass, kg at passage-way
width, mm:
- 600 mm
- 800 mm
- 900 mm
- 1000 mm
- 1200 mm
50,0
54,0
56,0
58,0
62,0
Weight of the gate with a metal tube flap, kg at
passage-way width, mm:
- 600 mm
- 900 mm
- 1000 mm
- 1200 mm
50,0
56,0
58,0
62,0
Temperature range, °С:
- operation
- transportation and storage
+1...+40
+1...+40
Relative humidity, %, max.
80
Width of formed passage, mm
600-1200

ВЗР.248100.000OM
Gate K-14
Operation Manual
6
Throughput, pers./ min
10
Service life, years
8
Supplied voltage, V
- rated
- operational
24,0
19,0...29,0
Average current in standby mode*, A
0,4
Average current in passage mode*, A
0,5
Maximum consumption current*, A
8,0
Note - * Values of current are given for rated supply voltage
ATTENTION: THE CAPACITY DATA WERE OBTAINED IN
EXPERIMENTAL TESTING AT 600 MM FLAP, WITH NO PAUSES BETWEEN
OPENING AND CLOSING.
Product structure.1.1.4
All gate structure members are made of polished stainless steel, the flap is
made of hardened glass.
The gate includes a stationary stand with an enclosure, floor mounting cup,
indication panel, upper rotary enclosure with electric drive and glass flap.
Gate flap rotation at 180° (+90°-90°) is available.
Figure 1 –gate overall view.

ВЗР.248100.000OM
Gate K-14
Operation Manual
8
Figure 2 –Gate overall dimensions for passage-way width of 600 mm
Marking contains manufacturer's trademark, designation and1.1.6
serial number.
Overall dimensions of packing case.1.1.7
Gate overall dimensions with glass, mm:
1) Gate with passage-way width of 600 mm –940х685х110;
2) Gate with passage-way width of 800 mm –985х940х110;
3) Gate with passage-way width of 900 mm –985х940х110;
4) Gate with passage-way width of 1000 mm –1080х940х110;
5) Gate with passage-way width of 1200 mm –1220х940х110.
1.2 Product indication panel
The gate has a three-color indication(Figure 1 –3, indication panel):
1) Green –passage is permitted (flap open);
2) Red –passage is forbidden (flap closed);
3) Yellow-green –powering initialization mode (during power supply).

ВЗР.248100.000OM
Gate K-14
Operation Manual
9
2 INTENDED USE
2.1 Operating limits
ATTENTION: FAILURE TO COMPLY WITH THE SAFETY
REQUIREMENTS SPECIFIED IN THIS SECTION CAN RESULT IN DEATH AND
DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF PERFORMANCE
OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT.
ATTENTION: THE PRODUCT SHALL BE INSTALLED BY
QUALIFIED PERSONNEL IN ACCORDANCE WITH INSTALLATION MANUAL
ATTENTION: THE CONTROL PANEL WORKS ONLY AT A
DISTANCE OF 5 METERS FROM THE GATE. THIS IS THE DISTANCE OF THE
STANDARD CABLE SUPPLIED WITH THE GATE.
ATTENTION: MANUFACTURER WAIVES ANY RESPONSIBILITY
FOR DEATH AND DAMAGE TO HEALTH, COMPLETE OR PARTIAL LOSS OF
PERFORMANCE OF THE PRODUCT AND/OR AUXILIARY EQUIPMENT IF
USER FAILS TO COMPLY WITH THE SAFETY REQUIREMENTS SPECIFIED
IN THIS SECTION, AND ALSO VOIDS THE PRODUCT WARRANTY.
DO NOT:

ВЗР.248100.000OM
Gate K-14
Operation Manual
10
INSTALL THE POWER SUPPLY MODULE INSIDE THE PRODUCT BODY
AS IT MAY RESULT IN ELECTRIC SHOCK TO PERSONS.
INSTALL THE PRODUCT OUTSIDE DRY AND HEATED ROOMS.
OBSTRUCT OR ACCELERATE THE PRODUCT FLAP MOVEMENT
WHEN TURNING ON (OFF) THE ANTI-PANIC MODE.
APPLY PASTES AND LIQUIDS CHEMICALLY AGGRESSIVE TO
MATERIALS OF THE HOUSING WHEN CLEANING THE PRODUCT.
2.2 Preparing the product for use
2.2.1 Safety measures during product preparation
ATTENTION: TO AVOID INJURIES TO PERSONS AND PRODUCT
BLOCKING, MAKE SURE THAT THERE ARE NO PERSONS AND FOREIGN
OBJECTS WITHIN THE FLAP ROTATION AREA PRIOR TO THE PRODUCT
CONNECTION.
2.2.2 Rules and procedures for visual inspection of the product
Visual inspection of the product before connecting to the mains shall be
obligatory and include:
1) check for product housing mechanical damage: cracks, through holes resulted
from fasteners drop-out;
2) thorough inspection of all connections of the product.
2.2.3 Turning on the product.
Connect the PSU to ~220 volts mains and turn it on. When turned on, the
indication panel lights in yellow-green, calibration takes place. The product flap