OptoSigma SRC-101 Manual de usuario

1 Copyright 2012, OptoSigma Inc.
SRC-101
Remote Controller for SGDC Actuators
Instruction Manual
Ver. 1.1

2
OPTOSIGMA CORPORATION
3210 SOUTH CRODDY WAY, SANTA ANA, CALIFORNIA 92704 USA, TEL. 949-851-5881, E-MAIL SALES@OPTOSIGMA.COM
Points to note when using this document and this product
This document is for customers to use this product appropriately, so please check the following
contents before using it.
1. The technical information in this document does not grant a license to the implementation or
use of intellectual property rights and other rights owned by OptoSigma Inc.
2. The technical information in this document is current at the time of publication and is subject
to change without notice.
3. The technical information in this document has been prepared accurately and carefully, but
OptoSigma Inc. will not be liable for any damage caused by an error in the description of the
material.
4. Reproduction or reproduction of this material requires the prior written consent of OptoSigma
Inc.
For inquiries and consultations regarding use, please contact the following sales staff.

3 Copyright 2012, OptoSigma Inc.
For safe use
Before use, please read this "For safe
use
"
and "
Instruction manual” carefully and use it correctly. This manual indicates the matters
that should be observed in order to prevent harm to users and others and damage to property, and to use it safely.
After reading this manual, please be able to view it at any time when using this product.
About warning displays
The warning labels are intended to help you use this product safely and correctly, and to prevent harm or damage that may be inflicted on you or
others. Please read this manual after understanding the contents.
!
Warning
!
Attention
Ignoring this indication indicates that mishandling could result in
death or serious injury to the user.
Ignoring this indication indicates content that may result in
personal injury and that may cause property damage.
Disclaimer
(1) The Company shall not be liable for any incidental damages arising from the use or inability to use this product.
(2) The Company shall not be liable for any damage caused by usage other than those described in the instruction manual.
(3) Damage caused by fire, earthquake, act by a third party, other accident, intentional or negligent act of the user, misuse, or use under other
abnormal conditions.
The Company shall not be liable for any such matters.
Cautionary note
!
● Flammable gas, explosive or corrosive places, moisture or humid places,
breathable
Do not use in bad places or near flammable materials.
● Do not connect or inspect in an energized state.
● Installaon (installaon) and connecon work should be performed by a
technician with specialized knowledge.
● Do not touch the inside of the device at all.
● Power cables, motor cables, and connecon cables can be bent or pulled,
Do not damage or process.
● If there is an abnormal smell, overheang, heat generaon, or abnormal
noise, turn off the power.
● If the device is dropped or subjected to a strong impact, do not turn on the
power.
● Please use a dry cloth for cleaning.
● Do not operate with wet hands or other actions that may cause electric shock.
● For places with vibraon, sealed places, places exposed to direct sunlight, etc.
Do not leave it unattended.
● When unplugging the power plug, hold the power plug without pulling the
power cable
Please unplug.
● Even if the power is turned off, there is residual voltage, so touch the input /
output terminals for
about
10
seconds.
Please don't.
● Before connecng the equipment material, the inial seng
(
parameter
settings).
● Please connect the equipment after turning off the input power.
● Turn on the power (operaon) with the power turned off immediately when
an abnormality occurs
.
Please.
● Never disassemble, modify, repair, etc.
● Do not use outdoors.
!

4
OPTOSIGMA CORPORATION
3210 SOUTH CRODDY WAY, SANTA ANA, CALIFORNIA 92704 USA, TEL. 949-851-5881, E-MAIL SALES@OPTOSIGMA.COM
Chapter 1: Before You Begin
1. Check the package contents
When using this device for the first time, please check □ and check that all of the following items are
available.
If the accessories are missing or damaged, please contact our sales department.
SRC
-
101 Product
Contents
(Standard Equipme
n
t)
□ SRC
-
101 Main Unit
1 unit
□ AC Adapter
1 pc
□ Simple instrucon manual
1 unit
□ Bump pong (non
-
slip)
1 Sheet
* Banpons can be used as anti-slip when placed on the floor or desk. SRC-101 Please attach it to the main unit and
use it.
SRC-101 Option (sold separately)
Model No. □ Compable Remote Actuator - SGDC10-13
* SRC-101 is compatible with our remote actuators.
□ MDC Cable Model No.: MDC-4-△
* This is an extension cable for compatible remote actuators. Model number △ contains the cable length (2, 3,
5[m]).
* Operation cannot be guaranteed when multiple extension cables are connected to 5 m or more.
□USB cable Model No.: USB/MINI-B-△
* Used when controlling from a PC. The model number △ contains the cable length (2[m]).
* To control this device by a computer, the driver must be installed on the PC side.
See Chapter 3 for installation instructions.

5 Copyright 2012, OptoSigma Inc.
2. Overview
The SRC-101 (this device) is a dedicated controller for remote actuator drive. Micrometer-like micro-movements with
fine movement knobs and simple manual operation with JOG switches are possible. It is also
possible to control the
actuator by connecting to a commercially available PC
via a USB interface and sending commands from the PC.
3. Name and function of each part
3-2.
Functions of
each part
(1) Gear shift knob
This knob sets the operating speed of the actuator. Overloads can be detected at
the silver scale. (*The scale is only a guide)
②RUN LED
The green LED lights up
during actuator operation
.
3-1.
Name of each part
③
STOP LED
④
JOG
switch
(1) Speed shift
knob
②
RUN LED
(5) Fine
movement knob
Front Panel Side
⑧Power
terminals
⑨Power switch
⑦
Motor Connectors
⑥USB
connector
Rear panel side

6
O
PTO
S
IGMA
C
ORPORATION
3210
S
OUTH
C
RODDY
W
AY
,
S
ANTA
A
NA
,
C
ALIFORNIA
92704
USA,
TEL.
949-851-5881,
E-
MAIL SALES
@
OPTOSIGMA
.
COM
③STOP LED
When an alarm is detected, the red LED lights up or blinks to indicate an abnormality.
See 6.
See
Alarms
(
page
8).
(4) JOG switch
The actuator can be operated at a constant speed (jog operation).
(5) Fine movement knob
This knob allows you to operate the actuator like a micrometer.
(6) USB connector
It is used when controlling by serial communication.
* DX2R005HN2 (equivalent to Japan JAE Industries, Ltd.)
(7) Motor connector
Connect a compatible remote actuator or MDC cable. The connector is lockable, so
do not pull the cable forcibly when inserting and removing.
(8) Power supply terminal
Connect the
dedicated
AC adapter. Do not use anything other than accessories.
(9) Power switch
Turn on the ON side to turn on the power. Turn off the power when it is turned
off.
Chapter 2 Operating the SRC-101 (Manual Operation)
4. SRC-101 Connection Procedure
4-1. Connect the SRC-101
and
the remote
actuator
to this device and the actuator to be used.
(1) Make sure that the power is not turned on to this device.
(2) Connect the actuator to the motor connector of this device.
4-2. Connect the SRC-101
to the AC adapter
Connect
the dedicated
AC adapter
to this unit.
(1) Make sure that the power is not turned on to this device.
(2) Connect the AC adapter to the power terminal of this unit.
4-3. Powering on
Turn the power switch on the ON side and turn on the power to this device.
The front panel RUN and STOP LEDs
illuminate simultaneously when power is applied and
turn off
simultaneously after
approximately 1
second
.
* If the LED does not light up
,
check the connection of the AC
adapter
.
caution
When connecting various cables, be sure to connect with
the power
turned off.
5. Basic operation
This device can easily operate the actuator by manually operating the switches and knobs on the front panel. The basic
operation method is described below.

7 Copyright 2012, OptoSigma Inc.
5-1. Operation of the shifting knob
The actuator operation speed can be switched during panel operation.
・
High-speed operation on the FAST side and low-speed operation on the SLOW side.
5-2. JOG Switch Operation
The actuator can be jogged manually.
• When the JOG switch
is tilted to the FWD side, the actuator operates in the direction of extension
(+direction).
• When the JOG switch is tilted to the REV side, the actuator operates in the direction of contraction
(-direction).
• The RUN LED lights up when the actuator is operating.
・
Release the JOG switch to stop.
5-3. Operation of fine movement knob (1)
By turning the fine movement knob, the fine movement of the actuator can be performed. Rotation of the knob The
actuator moves with each click, realizing intuitive operation like a micrometer.
・
Knob FWD Turn to the side - the actuator works in the + direction
。
• When the knob is turned to the REV side, the actuator moves in the - direction.
• The RUN LED lights up when the actuator is operating.
* The amount of movement (resolution) at the time of one click of rotation varies
depending on the set speed.
The higher the set speed, the greater the amount of travel.
5-4. Operation of fine movement knob (2)
You can jog the actuator by turning it while pressing the knob. The operating speed varies depending on the number of
clicks from the position where the knob is pressed. The more clicks, the faster it will work. Regarding this operation, the
speed set by the shifting knob will be invalid.
・
From the position where the knob is pressed FWD When turned to the side, the
actuator operates in the + direction
。
• When the knob is turned from the position pressed
to the
REV side, the actuator
moves in the - direction.
・
By fixing the pressed state, the jog works at a speed according to the number of
clicks.
• The RUN LED lights up when the actuator is operating.
・
Stops when the knob is released.
6. Alarm
This device is equipped with an alarm for safety. Automatically stops actuator operation when an alarm is detected
turn
Push and turn

8
OPTOSIGMA CORPORATION
3210 SOUTH CRODDY WAY, SANTA ANA, CALIFORNIA 92704 USA, TEL. 949-851-5881, E-MAIL SALES@OPTOSIGMA.COM
I will. When an alarm is detected, the STOP LED lights up or blinks.
6-1. Overload detection
When jogging at a specified speed or higher, this device detects overload at the end of the stroke and automatically
stops operation. When an overload is detected, the front panel STOP LED lights up. Overload detectable speed setting
ranges from 16~48
(Limited to the silver mark scale of the shifting knob). If you operate in the opposite direction from the detected
direction, the alarm will be canceled.
However, please note that the end of the stroke may not be detected depending on the operation by the fine
movement knob or M command, low-speed operation, wiring conditions, etc. If the stroke end is reached, the actuator
is often mechanically locked and may not be able to get out. When exiting the stroke end, operate at high speed.
Also, if an overload is detected in the middle of the stroke, the torque of the motor is insufficient. Please use at a speed
that does not stop by increasing the speed.
6-2. Long-running alarm
In order to prevent the motor from generating heat due to continuous operation for a long time, the actuator stops
operating after a specified period of time. When a long-running alarm is detected, the front panel STOP LED blinks once
per second. Turn the power off, wait for a while, and then turn it back on.
Setting speed
Long motion detection time
48
100 seconds
47
150 seconds
46
200 seconds
45
300 seconds
44
600 seconds
1~43 3000 seconds
6-3. Internal circuit overload detection
When this device detects an abnormality in the internal circuit, it automatically stops the operation of the actuator.
When an alarm is detected, the front panel STOP LED blinks twice per second. Turn off the power, stop using and check
the load status.
Chapter 3 Operating the SRC-101 with a Personal Computer (Serial Communication)
7. SRC-101 Connection Procedure
7-1. Driver installation method ( MS Window’s example)

9 Copyright 2012, OptoSigma Inc.
This device uses FTDI's FT232
for
USB-to-serial conversion. To control this device by a computer, you must first install
the driver on the PC side.
The following example
describes the installation procedure
of
Driver Ver.2.08.08
for
Windows 32bit.
Windows
is a registered trademark of
Microsoft Corporation in the United
States and other countries.
(1) Access
FTDI's website (http://www.ftdichip.com/index.html)
(2) Download the driver corresponding to
the
OS from
Drivers
>
VCP Drivers > the left item
.
(Please note that the structure of the homepage may change.)
)
(3) Unzip the zip file
Download example
Defrosting
example
(4) Connect the USB mini-B
(
male)
end of the USB cable to the
USB connector
on the rear panel of the device.

10
OPTOSIGMA CORPORATION
3210 SOUTH CRODDY WAY, SANTA ANA, CALIFORNIA 92704 USA, TEL. 949-851-5881, E-MAIL SALES@OPTOSIGMA.COM
Connect the USB A (male) end of the USB cable to the USB port on your computer .
(5) Connect the AC adapter to the power terminal of this unit.
(6) Turn on the power.
(7) Follow the instructions in the Found New Hardware Wizard to start the driver installation.
First, select Install from a list or a specific location.
(8) Specify the unzipped folder.
(9) Install USB Serial Converter
Tabla de contenidos
Otros manuales de Controladores de OptoSigma

OptoSigma
OptoSigma CJ-200A Manual de usuario

OptoSigma
OptoSigma GSC-01 Manual de usuario

OptoSigma
OptoSigma GSC-02A Manual de usuario

OptoSigma
OptoSigma JD-101 Manual de usuario

OptoSigma
OptoSigma GSC-02 Manual de usuario

OptoSigma
OptoSigma SHOT-102 Manual de usuario

OptoSigma
OptoSigma JC-01 Manual de usuario