Xperience platform
All of Nexmosphere’s controllers are built on the same platform principles. If this is your rst time using a Nexmosphere
controller, we recommend to rst read https://nexmosphere.com/technology/xperience-platform/ to learn the basics about
our platform and its terminology.
XN-115 Xperience controller
The XN-115 is an Xperience controller with 1 X-talk interface.
It serves as the interface between the sensor and your digital signage player.
1. X-talk interface 001
USB. 5V Power input and API interface (micro-USB connector)
LED. White status LED
XY-240 Presence & Airbutton sensor
The XY-240 Presence & Airbutton sensors can detect if a person is in front of the sensor and - if so - indicate the distance
of that person in relation to the sensor. Next to this, the sensor will provide an Airbutton trigger when a person places their
hand close to the sensor.
Hardware setup
1. Connect the presence sensor to the X-talk interface of the XN-115 controller
2. Connect the micro-USB cable to a 3rd party device (e.g. Digital Signage Player or PC).
3. Wait until the white status LED stops blinking. This lasts about 5 seconds.
XN
1 2
Software setup for testing (Terminal)
Typically, the XN-115 controller is connected to a 3rd party device, such as a Digital Signage Player, on which CMS software is installed which has built-in
functionality for sending and receiving Serial Events. However, if you want to do a rst test on a PC or Mac, follow the instructions below:
1. Download a terminal program. For example Termite or Hercules.
2. Open the Terminal program and go to settings. Choose the COM port on which the XN-115 controller enumerated*.
In most cases this is the highest available number in the COM port drop-down setting.
3. Set the COM port settings to the following values
Baudrate 115200 Flow Control None
Parity None EOL CR+LF
Data Bits 8 Protocol ASCII
Stop Bits 1
4. Set the COM port to “Open”. The controller and sensor are now ready for use.
*In case the XN-115 controller is not recognized as a COM port by the 3rd party device, a driver (Prolic PL2303GL) can be downloaded here.
Nexmosphere
Le Havre 136
5627 SW Eindhoven • The Netherlands
T +31 40 240 7070
Esupport@nexmosphere.com