netvox ZigBee ZL01A Manual de usuario

ZigBeeTM- Combined Interface
User Manual
Combined Interface
Model: ZL01A
FW V4.4
HW V1.3

1
Table of Contents
1. Introduction.............................................................................................................................................................. 2
2. Product Appearance.................................................................................................................................................3
3. Specification.............................................................................................................................................................. 4
4. Installation.................................................................................................................................................................4
5. Setting up ZL01A..................................................................................................................................................... 6
5-1. Join the ZigBee Network................................................................................................................................ 6
5-2. Permit-Join...................................................................................................................................................... 6
5-3. Transparent Transmission Mode.................................................................................................................... 6
5-4. Restore to Factory Setting...............................................................................................................................8
6. Home Automation Clusters for ZL01A................................................................................................................. 8
7. Netvox APP Interface.............................................................................................................................................10
8. Important Maintenance Instructions................................................................................................................... 12

2
1. Introduction
Netvox ZL01A, the ZigBee gateway, acts as a Coordinator or a Router Device in ZigBee network. It is designed to
interface the RS-232 interfaces with ZigBee network. There are two transmission modes: the data-transmission
mode and the command-transmission mode. Any terminal is able to send data wirelessly via ZL01A under the
data-transmission mode. Under the command-transmission mode, it is able to collect network information using
ZigBee application.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple
network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a
general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for
industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation
and home automation, etc.

3
2. Product Appearance
Network Indicator
USB Port
Permit-join Key
RS232

4
3. Specification
Fully IEEE 802.15.4 compliant
Utilizes 2.4GHz ISM band; up to 16 channels
Power supply: 5V DC
Up to 150 meters wireless transmission range in non-obstacle space
Easy installation and configuration
4. Installation
This device is NOT truly waterproof/ resistant and is for indoor use.
USB to ZL01A
USB to computer

5
RS232
RS232
RS232
USB

6
5. Setting up ZL01A
5-1. Join the ZigBee Network
A. When ZL01A is a Coordinator.
It will establish a ZigBee network after powering on. The indicator will stay ON after the network is created
successfully. Otherwise, the indicator will be OFF.
B. When ZL01A is a Router Device.
It will search for an existing ZigBee network and send a request to join the network automatically after
powering on. While ZL01A is under the coverage from a coordinator or a router whose permit-join feature is
enabled, ZL01A will be permitted to join the network. The indicator will stay ON after it is joined
successfully.
5-2. Permit-Join
ZL01A is designed to work as a coordinator or a router. To allow other devices to join the ZigBee network,
users could enable the Permit-Join feature using the tips:
A. Press the Permit-join Key once to enable the Permit-Join feature. The indicator will flash once per second.
B. The default Permit-Join period of time is 60 seconds.
5-3. Transparent Transmission Mode
ZL01A performs three transmission modes:mode 1, mode 2, gateway mode
(1) Transparent transmission mode 1:
Baud Rates which ZL01A supports: 115200bps, 57600bps, 38400bps, 28800bps, 19200bps, 9600bps, 4800bps,
2400bps, 1200bps. Default baud rate is 9600bps. If users would like to change baud rate, it must be done before
leaving the factory or through Netvox OTA programming to modify.
Process: Send GetPollData Request command via Z206/Z103A/B USB dongle. SendDataPayload is the real data
needed to be sent to ZL01A serial port. When ZL01A gets the command, it will get data from SendDataPayload
and sned it to target device via RS231 interface. When ZL01A receives the serial port data through RS232, it will
fill the serial port data to RecDataPayload field according to the GetPollData response command and send it to the
destination address by air.

7
Mode one requests to cooperate with Z206/Z207 and REST API document.
Wireless transparent transmission command:
.GetPollData Request(PC Side ZU)
Cmd=0x0F21 Len=var AddrMode DstAddr DstEndPoint Cluster
ID
SendDataPayload
AddrMode – byte –indicates that the DstAddr is either 16 bits ShortAddress (Addrmode = 0x02) or
16 bits GroupAddress (Addrmode = 0x01)
DstAddr – 2 bytes –network address of the destination address.
DstEndpoint – byte – the destination EndPoint. represents the application endpoint the data.
Cluster ID – 2 byte –Netvox MIX ClusterID.(0E60)
SendDataPayload—var bytes—PayloadData Send From PC API(MAX=76bytes)
GetPollData Response(Sensor Side Module)
Cmd=0x1F21 Len=var SrcAddr SrcEndPoint Cluster ID RecDataPayload
SrcAddr– 2 bytes –network address of the source address.
SrcEndPoint– byte – the source EndPoint. represents the application endpoint the data.
Cluster ID – 2 byte –Netvox MIX ClusterID.(0E60)
RecDataPayload—var bytes—PayloadData Rec From Sensor(MAX=76bytes)
(2) Transparent transmission mode 2:
ZL01A receives RS232 serial data, the original serial data is sent to the air in the form of broadcast, for
example, data 010203 can be sent directly through the RS232 to ZL01A and it can pass data 010203 to the air.
ZL01A receives the air data, the original data will be sent directly to the serial port. For example, data 010203
is sent through RS232 of ZL01A to the air and let another ZL01A receives data and pass it through RS232 to
the corresponding device.
(3) Gateway mode:
Sending data and receiving data are strictly following Netvox << Profile Standard Command.doc >> user
manual.
(4) To switch the modes between mode 2 and gateway mode, please use below command format:
ZL01A
RS232
ZL01A
RS232

8
The command format is as following:
02 Cmd=0x0FFE Len=0x11 Data CRC
Mode 2: Data is "www.netvox.com.cn" hexadecimal code. Send serial command
"020FFE117777772E6E6574766F782E636F6D2E636ECB", when receiving the "021FFE0100E0" that it is
successful to change to mode 2.
The Gateway mode: Data is "WWW.NETVOX.COM.CN" hexadecimal code. Send serial command
"020FFE115757572E4E4554564F582E434F4D2E434ECB", when receiving the "021FFE0100E0" that it is
successful to change to Gateway mode.
5-4. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Power off ZL01A.
Step2. Press and hold the Permit-join Key.
Step3. Do not release the key and power on ZL01A to complete the restore.
6. Home Automation Clusters for ZL01A
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by ZL01A.
1.End Point(s):0x0A
2.Device ID:Combined Interface(0x0007)
3.EndPoint Cluster ID
Server side Client side
Mandatory
Basic(0x0000)
Identify(0x0003)
Commissioning(0x0015)
Diagnostics(0x0B05)
Optional

9
This lists the attributes of the basic information.
Identifier Name Type Range Access Default Mandatory
/ Optional
0x0000 ZCLVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x03 M
0x0001 ApplicationVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x28 O
0x0002 StackVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x33 O
0x0003 HWVersion Unsigned
8-bit integer
0x00 –
0xff
Read only 0x0D O
0x0004 ManufacturerName Character
string
0 – 32
bytes
Read only netvox O
0x0005 ModelIdentifier Character
string
0 – 32
bytes
Read only ZL01AE3C/
ZL01AE3R
O
0x0006 DateCode Character
string
0 – 16
bytes
Read only 20130108 O
0x0007 PowerSource 8-bit
Enumeration
0x00 –
0xff
Read only 0x04 M
0x0010 LocationDescription Character
string
0 – 16
bytes
Read/write O
0x0011 PhysicalEnvironment 8-bit
Enumeration
0x00 –
0xff
Read/write 0x00 O
0x0012 DeviceEnabled Boolean 0x00 –
0x01
Read/write 0x01 M
Tabla de contenidos
Otros manuales de Puerta de netvox
Manuales populares de Puerta de otras marcas

LST
LST M500RFE-AS Manual de usuario

Kinnex
Kinnex Media Gateway Manual de usuario

2N Telekomunikace
2N Telekomunikace 2N StarGate Manual de usuario

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manual de usuario

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manual de usuario

Telsey
Telsey CPVA 500 - SIP Manual de usuario