Opera� ng Manual
Hyperion 314IPS
Hygienic Short-Range DC Bar
So� ware Version:3.02 Copy Version:1


Products shown in this document may be covered by one or more patents, patents applied for
and/or registered designs and/or trade marks. For further information please refer to our Head
Oce or visit www.meech.com.
© Meech Static Eliminators Ltd., 23.08.2021
Contents
Introduction
Unpacking And Inspection
Contents
Standard
Options
Feature and Benets
Low Voltage Wiring and Integrated Power Supply
Shockless Emitters
Sealed and Hygienic Construction
Clear Pin Alert and Fault LED
Dual Alarm Lines – Clean Pin Alert and Fault Output
Divider
Mounting
Installation
Mechanical Installation
Electrical Installation
Connection using Meech 24V DC power supply
Connection using customer’s own power supply
Dual Alarm Alert – Remote Monitoring
Alarm Logic Level
Output Drive
Operation
Setting the Rate
Maintenance
Fault Finding
Cleaning
LED Status
Warning
Troubleshooting
Repairs and Warranty
CE Approval
Health and Safety
Technical and Construction
2
3
4
4
4
4
5
5
5
5
6
6
7
7
8
8
10
11
12
12
13
14
17
17
18
19
19
20
21
21
22
22
22
23


3
Introduction
The 314IPS is a compact pulsed DC ionising bar speci cally designed for use in
hygienic applications. Its PTFE construction is ideally suited to use on Hygienic food
and pharmaceutical machinery. It is used to control static electric charges in short-
range applications (20-150mm). To remove the potential for dirt traps, the bar is tted
with an integral power cable; allowing the connection to 24V to be made in a non-
hygienic area of the machine.
In most installations, the default settings of the bar will provide exceptional static
control. The local LED indicator shows the operational status of the bar and advises
when the bar requires cleaning. Demanding installations can take advantage of the
adjustable output of the 314IPS. Using the optional Hyperion BarMaster remote
programmer or SmartControl Touch, the frequency, balance and voltage output can be
optimised to suit the application.
Additionally, the lon Current alarm setting can be changed to guarantee the required
performance levels on critical processes. The dual alarm lines provide separate
signals for cleaning requirements and system faults, allowing the easy scheduling of
maintenance. The Hyperion BarMaster remote programmer and SmartControl Touch
are available for purchase from the Meech network:
Visit www.meech.com to nd your nearest Meech o ce or distributor for further
product information.

4
Unpacking And Inspection
Your Hygienic 314IPS bar was carefully packed at the factory in a container
designed to protect it from accidental damage. Nevertheless, we recommend careful
examination of the carton and contents for any damage.
If damage is evident, do not destroy the carton or packing material and immediately
notify the carrier of a possible damage claim. Shipping claims must be made by the
consignee to the delivering carrier.
Contents
Standard
Optional Extras
SmartControl Touch BarMaster 24v Switch Mode Power Supply
314IPS Hygienic Bar

5
Features and Benets
Low Voltage Wiring and Integrated Power Supply
The 314IPS Hygienic is powered by 24V DC via a 4-pin M8 Cable.
Shockless Emitters
The Titanium emitter pins on the 314IPS are resistively coupled to the high voltage
supply. This avoids sparking and operator shocks.
Sealed and Hygienic Construction
IP66 construction allows the bar to be mounted in areas subject to occasional wash-
down or spillage. If the bar does become wet it must be thoroughly dried before being
powered-up. Hygienic constructions also enable the use inside clean room conditions
where contaminants and residue on the bar are less than desired.
314IPS Hygienic Bar - Cable
314IPS Hygienic Bar - Base

6
Clean Pin Alert and Fault LED
The local LED illuminates constant green to indicate that the bar is on and working
correctly. Red ashing LED shows that bar is dirty and needs cleaning. Solid red
illumination indicates a fault with the high voltage output.
Green constant – OK
Green ashing – BarMaster remote programmer connected
Red ashing - Cleaning required
Red constant - Fault
Dual Alarm Lines - Clean Pin Alert and Fault Output
Dual alarm lines tell remote monitoring systems whether the ionising equipment needs
routine maintenance or whether there is a more serious system failure. The exible
con guration of the alarm system, allows the alarm lines to be interfaced with PLC’s,
buzzers and remote lamps.
Dual output signals indicate when the bar needs cleaning and when a fault has been
detected. The signal is 0V/24V output on pin 2 for Clean Pin Output and 0V/24V
output on pin 4 for Fault Alert Output. The default for Bar OK = 24V and for Bar needs
cleaning = 0V. For the Fault Alert Output the default is 0V. If required the signal can be
inverted using a BarMaster Remote Programmer or SmartControl. For example, Bar
OK = 0V, Cleaning Required = 24V
314IPS Hygienic Bar - Red Fault LED

7
Cleaning Recesses
The 314IPS is designed to operate in clean, hygienic environments. To maximise the
interval between cleaning, the design incorporates a unique feature surrounding each
high voltage pin, which increases the tracking distance between the two rows of pins.
It is important to clean this area during cleaning operations.
Mounting
When ordering a 314IPS bar up to 600mm in
length, it will be supplied with two M5 female
mounting points spaced evenly along the bar’s
length.
When ordering a 314IPS bar 600mm
and above in length, it will be supplied
with four M5 female mounting points
spaced evenly along the bar’s length.
These are built into the bar, providing a hygienic mounting option which is suitable
for use in clean rooms and also environments where hygienic practises are of high
importance.
Cleaning Recesses
314IPS Hygienic Mounng Locaons up to
600mm in length
314IPS Hygienic Mounng Locaons 600mm and above

8
Installation
Mechanical Installation
CAUTION
The 314IPS Bar should only be installed in the manner which it is designed for.
If the 314IPS Bar is used in any other way than instructed in this manual, it will
be considered improper use.
To install the 314IPS Bar the provided M5 female mounting points need to be used.
When ordering a 314IPS bar up to 600mm in length, it will be supplied with two M5
female mounting points spaced evenly along the bar’s length.
Correct positioning of the bar is vital for e ective static control. There must be no
metallic objects or obstruction between the bar and the material. The diagram shows
the area that should be kept clear.
Eff ec ve Distance vs Grounded Metal Where X Lengths are Equal
Tabla de contenidos
Otros manuales de Barra de iones de Meech

Meech
Meech 915 Manual de usuario

Meech
Meech 914EX Manual de usuario

Meech
Meech Hyperion 960IPS Manual de usuario

Meech
Meech 976 Manual de usuario

Meech
Meech 910 Manual de usuario

Meech
Meech 976EX Manual de usuario

Meech
Meech 971 Manual de usuario

Meech
Meech Hyperion 924IPS Manual de usuario

Meech
Meech 914 Manual de usuario

Meech
Meech 924EX Manual de usuario