IS 610 ECN 3946 Page 5 of 13
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material. Minimum
distances A 100mm B 1000mm –see Fig 1.
Ensure there is a space of at least (1000 mm) between the working surface and any
ceiling.
Install this appliance beneath an extraction canopy.
Connection of the supply cable is behind the fascia panel at the front of the
appliance. Remove the fascia and fit a suitable cable through the cable guide to the
terminal block.
Connection to a mains water supply is provided at the rear of the appliance. There
is also an overflow pipe that must be connected to a waste outlet in case of
accidental overfilling of the tank. The appliance must not be operated without water
in the tank, as it will result in the operation of the safety cut-out beneath the facia
panel. (See operating instructions). Check the fill rate. If it is considered excessive,
source and fit a flow restrictor.
The appliance may be manually filled via the fill box at the front of the appliance.
However, we do not recommend this as the regular way to fill the tank.
When the appliance has been installed in the intended position, the legs should be
adjusted to maintain a level top. Use a spirit level to determine that the chargrill is
level left to right and front to back. This procedure is critical, as it can affect the
safety cut-out operation and also assist the drainage of the appliance.
Anti-slip washers are provided to create a slip free pocket for the front feet, so
preventing movement during operation. Ensure the work surface is structurally safe
before installing the washers.
Ensure that the operator understands how to fill the water tank, safely operate,
shutdown and clean the appliance, and is aware of the position of the isolating
switch.
.