Lincat WMB3F/B Manual de usuario

IS435 ECN3461
User and Installation Instructions
Wall Mounted Water Boiler
WMB3F/B and WMB3F/W

IS435 ECN3461
2
Dear Customer
Thank you for purchasing this Lincat product.
With correct use and careful maintenance as described in these instructions, your Lincat
product will give years of trouble free use.
We produce over 450 different items of catering equipment and our range is constantly being
extended and improved. Find out more about Lincat products from your local distributor or
direct from us.
CONTENTS
CONTENTS .....................................................................................................2
SAFETY INFORMATION.................................................................................3
DELIVERY CHECKLIST ..................................................................................4
TECHNICAL SPECIFICATION ........................................................................4
ACCESSORIES...............................................................................................4
INSTALLATION ...............................................................................................4
OPERATION......................................................................................................5
CLEANING.......................................................................................................8
MAINTENANCE...............................................................................................9
DIAGNOSTIC MESSAGES............................................................................11
SERVICE INFORMATION .............................................................................11
GUARANTEE.................................................................................................12

IS435 ECN3461
3
SAFETY INFORMATION
To prevent injury to yourself or your staff, and to avoid damaging the
product, please read and follow the safety precautions below before setting
up and using the unit:
•Remove all plastic coatings and clean the unit before use.
•Always isolate the unit from the electricity supply before servicing.
•This unit must be earthed.
•Do not try to modify this unit.
•Never clean the unit with a water jet or steam cleaner.
•This unit is not suitable for outdoor use.
•Inform staff that the outer surfaces will become hot.
•Keep these instructions in a safe place near the unit for future reference.

IS435 ECN3461
4
DELIVERY CHECKLIST
If an item is missing please contact your dealer immediately.
•Electric water boiler
•User instructions
•Guarantee card
•44mm diameter rubber grommet
Note: No supply cable or connection hose is supplied with this unit
TECHNICAL SPECIFICATION
Model WMB3F
Width mm 300
Depth mm 185 Exc. tap
Height mm 415
Power Rating kW 3.0
Net weight (empty) kg 8.5
Net weight (full) kg 14.5
Ambient temperature
o
C 5 to 30
Water inlet pressure Bar 1 to 8
OPTIONAL ACCESSORIES
Replacement filter cartridge FC02
Drip tray DR72
MECHANICAL INSTALLATION
The boiler must be installed on a vertical surface, with the base in a horizontal position, in a
location where it can be supervised by trained personnel. Ensure that the location it is fitted in is
frost-free.
WARNING
The unit must be installed on a solid concrete / brick wall by a qualified fitter. Lincat does not
accept any responsibility for the safety of any unit not installed this way.
Use the template provided, IS436, to mark the position of the 3 mounting holes. Drill the wall
and insert suitable wall plugs.
Remove the glass front / outer body of the boiler. Loosen the screw holding the lower centre
trim, slide the trim forward, re-tighten the screw. Remove the screw in the top of the boiler. Lock
open the drain tap. Carefully slide the the glass front and metal sides upwards and away from
the unit. Secure the boiler to the wall using 5mm (10g) screws.

IS435 ECN3461
5
ELECTRICAL INSTALLATION
For safety regulations the plug or means of disconnection must always be accessible.
This boiler must be earthed.
Check that the voltage of your electricity supply corresponds to the voltage shown on the serial
plate.
The boiler is supplied with a terminal block suitable for flexible wires upto 6mm
2
. Connection
wires may either be threaded through the cutout in the back panel or via a suitable 20mm
diameter glanded bush in the unit base (After removing the smaller of the two knock out panels,
marked B.)
Connection sequence is as detailed below
E Earth Green / Yellow Right terminal
N Neutral Blue Centre terminal
L Live Brown Left terminal
WATER INSTALLATION
Connection hoses may either be fed through the cutout in the back panel or via the larger of the
two knock out panels in the unit base, marked ‘A’. A blank rubber grommet is supplied and
should be cut to fit around the feed pipe and fitted into the unit base to seal it.
The inlet connection point on the inlet solenoid valve is ¾”BSP and should be connected to the
mains water supply via an accessible isolating tap.
Connect the condesate / overflow pipe to a suitable drain, considering any applicable local
water regulations. If required, the internal pipe may be disconnected from the external
connector and the pipe extended to pass through the cutout in the back panel and connected to
a suitable drain.
Turn on the water supply to check that there are no leaks.
Refit the outer cover.

IS435 ECN3461
6
OPERATION
Layout of components
12
3
4
5
6
7
Key
1. Power Button
2. Fn Button
3. Filter
4. Knock-out for water
5. Knock-out for power
6. Grommet for tank drain
7. Overflow pipe

IS435 ECN3461
7
First use
1 Switch on the mains water supply and the electricity supply.
2 Leave the boiler for 15 minutes to allow it to fill completely.
3 Drain off approximately 3 litres of water to remove any loose carbon particles dislodged
from the filter.
Regular operation
The boiler starts automatically when the mains electrical supply is turned on. After a short delay
the unit fills with water and heats. During the heating cycle small quantities of water are added
to ensure that hot water is always available at the tap.
The water temperature, screen backlight and screen contrast can be adjusted as required.
The boiler is designed to be left permanently switched on: it is only necessary to turn it off for
descaling or maintenance.
Changing water temperature, screen backlight and contrast.
1 Turn power off at the wall for 5 seconds and then turn on again.
2 When the “Filter Flow” screen is displayed, press and hold the
power
button until the
software version is displayed. Press
Fn
and the temperature will be displayed.
3 Press the
power
button to cycle through the values 70 to 96 deg C. Press the
Fn
button to
select the required value.
4 The backlight adjustment screen is displayed next.
5 Press the
power
button to cycle through the values 1 to 25. Press the
Fn
button to select
the required value.
6 The contrast adjustment screen is displayed next.
7 Press the
power
button to cycle through the values 35 to 60. Press the
Fn
button to select
the required value.
8 Press the
power
button to exit.
Standby
If the boiler is to be left unused for a long period, the element can be turned off by pressing the
power button.

IS435 ECN3461
8
Filter replacement
The “FILTER” display shows the estimated remaining life in the current filter cartridge. When the
filter needs replacing, a reminder message is displayed. This is followed by the change filter
screen.
The boiler can be used without a filter but scale may build up more quickly and water taste may
be affected.
Replace the filter as follows:
1 Twist the base of the filter 90 degrees to the left and carefully lower the filter cartridge out
of the unit. It will contain a small amount of water.
2 Remove the black cap and place on the new filter.
3 Insert the filter fully into its recess and twist to the right to lock in place.
4 Press and hold the “Fn” button for 10 seconds to reset the filter life monitor.
5 Drain off approximately 3 litres of water to remove any loose carbon particles from the
filter.
CLEANING
Clean the external surfaces of the unit regularly to maintain hygiene.
Wipe the dispensing tap daily to remove any limescale deposits and check that the water outlet
is clear.
Wipe the unit down with a damp soft cloth.
Do not allow excess water to run into the unit.
Do not use abrasive creams or scourers.

IS435 ECN3461
9
MAINTENANCE
Filter: Twist to the left and remove. See section on filter replacement.
Descaling
The descaling procedure must be performed by trained personnel as it requires the
removal of panels from the boiler and access to live electrical components.
The boiler should be descaled regularly to maintain efficient operation and water quality. The
frequency depends on the hardness of the local water and the timely replacement of the filter.
The boiler is best descaled at the end of the working day to allow the descaling agent several
hours to work. Lincat recommends its own descaling agent, available from Lincat spares
department, part code MS19.
1 Wear protective clothing.
2 Isolate the boiler from the electricity supply.
3 Turn off the power and let the water cool to approximately 60ºC to avoid injury.
4 Remove the screw on the top of the boiler and slide off the body.
5 Remove the insulation on top of the tank, then unscrew and remove the tank lid.
6 Add the descaling agent a little at a time as some types can cause hot water to erupt.
Always follow the manufacturer’s instructions.
7 Replace the tank lid and outer body, and attach an “Out of Use” notice to the boiler to
prevent use during descaling.
8 Turn on the electricity and allow the boiler to heat and run normally for approximately 30
minutes.
9 Isolate the boiler and allow the water to cool.
10 Remove the outer body and tank lid and inspect the tank and level sensor housings for
scale deposits. If necessary repeat the descaling process.
11 Drain and flush all descaling agent from the tank completely as follows
i Unscrew the drain plug (Use a 24mm spanner to hold the plug and a 21mm socket on
a ratchet to remove it) from the bottom of the tank to drain all the water out.

IS435 ECN3461
10
A
DETAIL A
ii Flush out the tank with clean water.
iii When empty replace the drain plug and replace the cover.
12 Replace the tank lid, ensuring that the gasket is sealing the top of the tank correctly.
13 Fit the outer cover and turn on the boiler.
Otros manuales para WMB3F/B
1
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Caldera de Lincat

Lincat
Lincat EB3F Instrucciones de funcionamiento

Lincat
Lincat WMBFX Series Manual del propietario

Lincat
Lincat LWB2 Manual del propietario

Lincat
Lincat EB3 Guía del usuario

Lincat
Lincat EB3F Manual del propietario

Lincat
Lincat Opus OG7003 Guía del usuario

Lincat
Lincat LWB2 Manual de funcionamiento

Lincat
Lincat EB3FX/HC Manual del propietario

Lincat
Lincat EB3HC Manual de servicio

Lincat
Lincat EB3F/PB Manual del propietario