LG PQCSD130A0 Manual de usuario

P/NO : 3828A20860S www.lg.com
INSTALLATION MANUAL
AIR CONDITIONER
TYPE : FUNCTION SCHEDULER
MODEL : PQCSD130A0
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
DUTCH
êìëëäàâ üáõä
ΕΛΛΗΝΙΚΆ
PORTUGUÊS

2Function Scheduler
Function Scheduler Ownerʼs & Installation Manual
TABLE OF CONTENTS
nSafety Precaution ............................................................................................3~4
n Part Description ....................................................................................................5
nSystem Drawing....................................................................................................6
n Installation instruction .....................................................................................7~9
Installation instruction........................................................................................7~8
Connection Method of Function Scheduler ...........................................................9
n Ownerʼs instruction ......................................................................................10~35
Individual operation .............................................................................................10
Total control for Each Group ...............................................................................10
Total control for All Group ...................................................................................10
Total On/Off operation.........................................................................................11
Selection of Indoor Unit.......................................................................................11
Cooling operation ................................................................................................12
Heating operation................................................................................................13
Dehumidification / Fan operation ........................................................................14
Auto Operation ....................................................................................................15
Temperature Control ...........................................................................................16
Celsius / Fahrenheit Switching............................................................................17
Fan Speed Control ..............................................................................................18
Setting Lock ........................................................................................................19
Changing Current Time..................................................................................20-21
Programming : Schedule Reservation ...........................................................22-25
Programming : Schedule Priority ...................................................................26-27
Programming : Setting On/Off Schedule.............................................................28
Programming : Deletion Schedule (Individual schedule) ....................................29
Programming : Deletion Schedule (Day schedule) .............................................30
Programming : Deletion Schedule (one indoor/group schedule) ........................31
Programming : Deletion Schedule (All schedule)................................................32
Programming : Schedule Copy ...........................................................................33
Programming : Holiday Reservation ...................................................................34
Programming : Self-diagnosis of Indoor Unit ......................................................35

Safety Precaution
Ownerʼs & Installation Manual 3
ENGLISH
Be sure to request to the
service center or installation
specialty store when
installing products.
• It will cause fire or electric shock
or explosion or injury.
Request to the service center
or installation specialty store
when reinstalling the
installed product.
• It will cause fire or electric shock
or explosion or injury.
Do not disassemble, fix, and
modify products randomly.
• It will cause fire or electric shock.
Do not place flammable
stuffs close to the product.
• It will cause fire.
Do not allow water to run
into the product.
• It will cause electric shock or
breakdown.
Do not give the shock to the
product.
• It will cause breakdown when
giving the shock to the product.
nInstallation
Safety Precaution
• The installation requires expert skills, and it should be installed by the service center or other shops specialized
in the installation and recognized by our company.
• For all the problems arising after installation by someone who has no relevant qualifications, our company will
not provide free service.
• The following safety cautions are provided to prevent unexpected dangers or losses.
: If the user does not follow the mandatory items, it may result in serious injury or death.
: If the user does not follow the mandatory items, it may cause personal injury or property
damage.
: Warning and Caution are to call the userʼs attention to the possible danger. Read and follow
them carefully in order to prevent a safety accident.
: Warning and Caution are indicated in this guide and the product itself to help protect the users
from danger.
WARNING
CAUTION
WARNING
nIn-use
TEMP
TEMP
TEMP
TEMP
TEMP

Safety Precaution
4Function Scheduler
nIn-use
CAUTION
Request to the service center or installation
specialty store when the product becomes wet.
• It will cause fire or electric shock.
Do not give the shock using sharp and
pointed objects.
• It will cause breakdown by damaging parts.
Do not clean using the
powerful detergent like
solvent but use soft cloths.
• It will cause fire or product
deformation.
Do not press the screen
using powerful pressure or
select two buttons.
• It will cause product breakdown or
malfunction.
Do not touch or pull the lead
wire with wet hands.
• It will cause product breakdown or
electric shock.
TEMP
TEMP
Wax
Thinner
TEMP
TEMP

Part Description
Ownerʼs & Installation Manual 5
ENGLISH
Part Description
Name and Function of Function Scheduler
OPERATION INDICATION
SCREEN
TOTAL ON/OFF BUTTON
OPERATION MODE BUTTON
ROOM TEMPERATURE
DISPLAY
FAN SPEED BUTTON
SCHEDULE SETTING MODE
BUTTON
HOLIDAY SETTING BUTTON
CURRENT TIME SETTING MODE
BUTTON
INDOOR SELECTION
CONFIRMATION BUTTON
SCHEDULE COPY BUTTON
SCHEDULE PASTE BUTTON
SCHUDULE/CURRENT TIME
SAVING BUTTON
CANCELATION BUTTON
UP/DOWN/LEFT/RIGHT BUTTON
TEMPERATURE SETTING
BUTTON
12V SIG GND
Please attach the inform label at inside of the cover.
Please choose proper language according to
your country.
1
2
6
3
7
4
5
8
9
10
12
13
11
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Function Scheduler
screw (4EA)
Owner's/ Installation
manual
Function Scheduler
installation board
Inform label
Accessory
jSome functions may not be operated and displayed according to the product type.

System Drawing
System Drawing
6Function Scheduler
Function Scheduler is connected as below figure.
As Function Scheduler can be connected up to maximum 8 central controllers, total 128 indoor units
can be controlled by Function Scheduler.
Indoor address must be set between 00 and 7F in hexadecimal code.
ON
L1 2 3 4
KSDO4H ON
L1 2 3 4
KSDO4H
Multi V II
Multi V
PI485
PI485
PI485
Simple Central
Controller Function
Scheduler
Multi
ON
L1 2 3 4
KSDO4H
j
Central controller and PI485 are products separately sold.
It is different as the outdoor unit.
NOTE
• Product that needs to be installed PI485
- Multi, Single, before Multi V II series
• Products that do not need to be installed PI485
- Multi V II Series

Ownerʼs & Installation Manual 7
ENGLISH
Installation instruction
12V SIG GND
Red
Yellow
Black
Function
Scheduler cable
Guide slot
Fixate Function
Scheduler cable
to the guide slot.
Use the screws
for fixate the unit
firmly on the wall.
Installation board
<Front side of
installation board>
<Rear side of
installation board>
Top
Bottom
Wall
Side
1. Connect Function Scheduler
cable to Function Scheduler
installation board as shown in the
right picture.
2. After fixing the cable to the guide
slot, attach Function Scheduler
installation board at the desired
location.
• Before fixing Function Scheduler cable to the
guide slot, remove any clogged part of the
case in the direction to install before the
installation.
3. After locating Function Scheduler
installation board at the desired
location, screw the unit firmly.
(When there is a buried box,
install Function Scheduler board
to fit the buried box.)
• Use the screws provided.
Installation instruction
12V Red wire
SIG Yellow wire
GND Black wire
jFunction Scheduler cable is connected as factory default.

8Function Scheduler
Installation instruction
Wall
Side
Wall
Side
Wall
Side
Wall
Side
4. After fixing the top part of the
remote controller to the installation
board as shown in beside picture,
press the bottom part to assemble
the controller to itʼs board.
When disassembling the remote
controller from the installation board, use
the driver as shown in the right picture
and insert it into the hole with the arrow.
And when you pull the driver in the front
direction, the remote controller will be
separated.
When installing Function Scheduler, do not bury it in the wall. (It can cause communication error.)
CAUTION

Ownerʼs & Installation Manual 9
ENGLISH
Installation instruction
Connection Method of Function Scheduler
Turn off the power before the connection of Function Scheduler.
CN_REMO
BR
BR
YL
YL
RD
RD
Central controller
CN_REMO
RD terminal (12V) Red
Yellow
Black
YL terminal (signal)
BR terminal (GND)
Function controller
cable
1
Connect colored cable of Function Scheduler to the corresponding terminal block of CN_REMO on the
PCB of the central controller.
2
Connect yellow wires and black wires to the corresponding terminal of the central controller CN_REMO
respectively as right where the central controller is installed the following figure.
The group address of central controllers must be set between 0 and 7.
3
Close the central controller case and check operation after turning on the power.
Caution
1. Use the communication cable provided with Function Scheduler.
2. Use 3P-0.75 Square Shield wires where cable extension is required.
3. Install cable length is within 1m.
4. If wiring is not proper, the product may be damaged or not operate when power is applied.

10 Function Scheduler
Ownerʼs Instruction
Individual Operation
Total Control for Each Group
Total Control for All Group
Ownerʼs Instruction
Press the individual Indoor On/Off button of
central controller to select a indoor unit to
control. Then current condition of corresponding
unit is displayed and icon is appeared.
The selected unit will operate.
Press the Total On button of central controller to
select all units of the group to control.
Then corresponding group units operate
sequentially and current condition of
corresponding groupʼs first unit is displayed
and icon is appeared.
All indoor units of the group will operate.
Press the Total On button of central controller for
2~3 seconds to select all units to control.
Then, all units operate sequentially and current
Condition of 1st unit of 1st group is displayed
and icon is appeared.
All indoor units will operate.
Otros manuales para PQCSD130A0
1
Tabla de contenidos
Otros manuales de Termostato de LG
Manuales populares de Termostato de otras marcas

EWELLY
EWELLY EW-181 Manual de usuario

Prolon
Prolon T1100 Instrucciones de instalación

Computherm
Computherm Q20 Manual de usuario

Heatmiser
Heatmiser neoStat Manual de usuario

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manual de usuario

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manual de usuario