GB Description of function of the flushing system
Battery / mains-operated urinal flushing system with flexible hose arrangement.
The flushing phase is time-controlled (timing intervals 2, 4, 8, 12, 18 or 24 hours) depending on the set flushing volume.
Flushing prevention with dismantled ceramic.
Startup [pictures 4, 5 ,6]
Put a battery into the contol unit, or plug in the mains connection, connect the cable, fix the control unit.
LED-display flashes 2 times long [figure 7]
Install the urinal, 3 min after the installation the system will be flushed 3 x approx. 2 sec. / break of 8 sec. / another flush of
approx. 2 sec. [figure 9]
The flushing system is ready to use! [picture 10]
GB Failure Cause Elimination
No rinsing Water supply interrupted
Filter clogged
Solenoid valve defective
Cable connections interrupted
Battery empty
Power supply interrupted
Open shut-off or pre-shut-off
Clean
Replace
Make connection
Replace
Guarantee voltage supply
Rinsing, low Water supply reduced
Filter clogged
Solenoid valve defective
Open shut-off or pre-shut-off
Clean
Replace
Rinsing, continues Solenoid valve defective Replace
Flush volume depending on the flow pressure
3 l
2 l
1,5 l
0,00
1,00
2,00
3,00
4,00
5,00
6,00
12345678910
Flow pressure [bar]
Flushvolume[lite