Invacare HomeFill II Manual de usuario

User: Before using the product, read this manual
and save for future reference.
Dealer: This manual must be given to the end user.
For more information regarding
Invacare products, parts, and services,
please visit www.invacare.com
Operator’s Manual
HomeFill™II Compressor

WARNING
HomeFill™II Compressor 2 Part No 1100873
WARNING
DO NOT OPERATE THIS EQUIPMENT WITHOUT
FIRST READING AND UNDERSTANDING THIS
MANUAL. IF YOU ARE UNABLE TO
UNDERSTAND THE DANGERS, WARNINGS,
CAUTIONS, AND INSTRUCTIONS, CONTACT
INVACARE TECHNICAL SERVICES BEFORE
ATTEMPTING TO USE THIS EQUIPMENT -
OTHERWISE, SERIOUS INJURY OR PROPERTY
DAMAGE MAY RESULT.
NOTICE
The information contained in this document is subject to
change without notice.
WARNING
Users MUST NOT SMOKE while using this device. Keep
all matches, lighted cigarettes or other sources of ignition
out of the room in which this product is located. Textiles
and other materials that normall would not burn are
easil ignited and burn with great intensit in ox gen
enriched air. Failure to observe this warning can result in
severe fire, propert damage and cause ph sical injur or
DEATH.
NOTE: Updated versions of this manual are available on
www.invacare.com.

TABLE OF CONTENTS
TABLE OF CONTENTS
HomeFill™II Compressor 3 Part No 1100873
SPECIAL NOTES ............................................... 4
TYPICAL PRODUCT ......................................... 5
PARAMETERS ................................................. 5
LABEL LOCATION ............................................ 6
DEALER INFORMATION ................................... 6
HOMEFILL II INFORMATION ............................. 7
SECTION 1—IMPORTANT SAFETY
INSTRUCTIONS ............................................... 8
Servicing of Double-Insula ed Produc s.......................................11
SECTION 2—INITIAL SETUP ............................ 12
Ini ial Se Up of Compressor..........................................................12
SECTION 3—CHECKLIST AND CYLINDER
INSPECTION .................................................. 16
Compressor Opera ion Checklis ................................................. 16
Cylinder Prefill Inspec ion ...............................................................16
SECTION 4—COMPRESSOR OPERATION .......... 23
Connec ing/Disconnec ing he Cylinder o/from he
Compressor........................................................................................23
Turning he Compressor On .........................................................29
Se ing he Flow Knob o he Prescribed Se ing ......................31
SECTION 5—INDICATOR LIGHTS .................... 32
SECTION 6—TROUBLESHOOTING CYLINDER
FILL TIMES ..................................................... 34
SECTION 7—MAINTENANCE .......................... 37
Cleaning he Compressor Fil er ....................................................37
Cabine ................................................................................................38
LIMITED WARRANTY .................................... 38

SPECIAL NOTES
HomeFill™II Compressor 4 Part No 1100873
SPECIAL NOTES
Check all parts for shipping damage. In case of damage, DO
NOT use. Contact Invacare for further instruction.
ignal words are used in this manual and apply to hazards or
unsafe practices which could result in personal injury or
property damage. Refer to the following table for definitions
of the signal words.
ACCESSORIES
There are many different types of humidifiers, oxygen tubing,
cannulas and masks that can be used with this device. You
should contact your local home care provider for
recommendations on which of these devices will be best for
you. They should also give you advice on the proper usage,
maintenance, and cleaning.
WARNING
Invacare products are specificall designed and
manufactured for use in conjunction with Invacare
accessories. Accessories designed b other manufacturers
have not been tested b Invacare and are not
recommended for use with Invacare products.
SIGNAL WORD MEANING
DANGER Danger indicates an imminently hazardous
situation which, if not avoided, will result in
death or serious injury.
WARN NG Warning indicates a potentially hazardous
situation which, if not avoided, could result
in death or serious injury.
CAUT ON Caution indicates a potentially hazardous
situation which, if not avoided, may result in
property damage.

Part No 1100873 5 HomeFill™II Compressor
TYPICAL PRODUCT
PARAMETERS
TYPICAL PRODUCT PARAMETERS
- COMPRESSOR
Regulatory Listing: Double Insulated Product
ETL ertified omplying with
UL73 and UL1097 (US)
ETL ertified omplying with
AN/ SA 22.2 No. 68 ( anada)
For household use only.
Operating temperature: 50 to 95° F (10 to 35° C) @ 20 to 60%
non-condensing humidity
Storage temperature: -10 to 150° F (-23 to 65° ) @ 15
to 95% humidity
Input Pressure Required: 14 - 21 psi
Input Flow Required: 2 L/min
Input O2 Required: >90% O2
Width: 20 ¼ inches
Height: 15 inches
Depth: 16 inches
Weight: 33 lbs
Shipping Weight: 39 lbs

HomeFill™II Compressor 6 Part No 1100873
LABEL LOCATION
DEALER INFORMATION
NOTE: Invacare recommends leaving a full cylinder of oxygen with
the patient after setting up the omeFill II compressor.
Before leaving a HomeFill II Compressor with a user, the
following checklist MU T be completed:
❑Make sure the pressure test on cylinder has not expired.
❑Instruct the user on the safe operation of the concentrator
and review all warnings.
❑Instruct the user on the safe operation of the HomeFill II
compressor and review all warnings.
❑Leave a full cylinder of oxygen with the user.
❑Leave a copy of all warnings and filling instructions with
the user.
Keep all connections free of oil and grease to avoid violent
ignition. See Owner's Manual before cleaning.
P/N 1075220 Rev C - 10/04
WARNING
!
DO NOT REMOVE UNIT COVER
This unit contains moving and high pressure
components. Manufacturer Service Only.
P/N 1075221
Rev B - 10/04
WARNING
!
Keep all connections free of oil and grease.
See Owner's Manual before cleaning.
Cylinders filled on this unit must be labeled "Contents of
this cylinder are the product of an oxygen concentrator."
P/N 1075238
Rev B - 10/04
WARNING
!

HOMEFILL II INFORMATION
HomeFill™II Compressor 7 Part No 1100873
HOMEFILL II INFORMATION
HomeFill II is an accessory device to the oxygen concentrator
that enables the patient to refill custom portable oxygen
cylinders for personal use.
NOTICE
The HomeFill II compressor is for use with speciall
designed Invacare Platinum™5, 10 and XL HomeFill II
compatible ox gen concentrators.
The ox gen concentrator can be set to the following
maximum flowrates when operating with HomeFill II
compressor:
Platinum 5 and XL: 3 L/min. or less.
Platinum 10: 5 L/min. or less.
To determine if our ox gen concentrator is HomeFill II
compatible, examine the lower right corner of the rear of
the ox gen concentrator for an outlet fitting. Refer to the
illustration below.

SECTION 1—IMPORTANT SAFETY INSTRUCTIONS
Part No 1100873 8 HomeFill™II Compressor
SECTION 1—IMPORTANT SAFETY
INSTRUCTIONS
WARNING
SECTION 1 - IMPORTANT SAFETY INSTRUCTIONS
contains important information for the safe operation and
use of this product. DO NOT use this product or an
available optional equipment without first completel
reading and understanding these instructions and an
additional instructional material such as Owner’s
Manuals, Service Manuals or Instruction Sheets supplied
with this product or optional equipment. If ou are unable
to understand the Warnings, Cautions or Instructions,
contact a health care professional, dealer or technical
personnel before attempting to use this equipment -
otherwise, injur or damage ma occur.
CAUTION
“Caution: Federal law restricts this device to sale b or on
order of a ph sician, or an other practitioner licensed b
the law of the State in which he/she practices to use or
order the use of this device.”
When using the HomeFill II, basic precautions should
ALWAY be followed, including the following:
WARNING
TO REDUCE THE RI K OF BURN ,ELECTROCUTION,
FIRE, OR INJURY TO PER ON .
NEVER use near any type of flame or flammable/explosive
substances, vapors or atmosphere.

SECTION 1—IMPORTANT SAFETY INSTRUCTIONS
HomeFill™II Compressor 9 Part No 1100873
DO NOT allow oil from your hands or other sources to come
into contact with the compressor coupling or bottle fittings.
These substances may become flammable in the presence of
oxygen and cause injury. Avoid touching the bottle fitting
whenever possible. Example of items to avoid are hand
creams or lotions, cooking oils, suntan oils or sunblocks and
similar oily products. If you use these types of products
Invacare suggests you wash your hands prior to using the
HomeFill unit. If the bottle fitting should come in contact with
such substances it should be cleaned off with a damp cloth
prior to connecting it to the compressor.
NEVER oil or lubricate the compressor coupler or bottle
fittings. NEVER use any penetrating oil or lubricant such as
WD-40 or 3 in One. If connection difficulty is experienced
verify that the bottle fitting is being inserted straight down
into the compressor coupler. If continued difficulty is
experienced contact your supplier for assistance.
Before moving or repositioning either the compressor or
concentrator, ALWAY push the power switch to the Off (O)
position, disconnect the AC power cord and the interconnect
hose between the compressor and concentrator. Failure to do
so may result in damage to the unit or personal injury.
Children should ALWAY be supervised around the
HomeFill II unit. When used with the HomeFill table or
similar elevated support surfaces, a child could pull over any
such table causing the unit to fall. Failure to observe this
warning may result in personal injury or product damage.
Use extreme care when handling and filling an oxygen
cylinder. Full oxygen cylinders are under pressure and can
become a projectile if dropped or mishandled.
NEVER transport a compressor with a cylinder connected to
or stored on the compressor, otherwise injury or damage can
occur.

SECTION 1—IMPORTANT SAFETY INSTRUCTIONS
Part No 1100873 10 HomeFill™II Compressor
DO NOT store filled oxygen cylinders near a furnace, hot
water tank, in the trunk of a car or other high temperature
area. torage in areas such as this can result in bursting of the
cylinder or fire.
The use of this device is limited to the oxygen patient.
Cylinders MU T be used ONLY by the oxygen patient and are
not to be distributed to any other individual for any purpose.
Invacare products are specifically designed and
manufactured for use in conjunction with Invacare
accessories. Accessories designed by other manufacturers
have not been tested by Invacare and are not recommended
for use with Invacare products.
DO NOT use outdoors.
The maximum patient flow while filling cylinders with the
IOH200 is 3 L/min. for Platinum 5 and XL, 5 L/min. for
Platinum 10. Patients with a higher prescribed flow should
not transfill while receiving supplemental oxygen treatment
from the Platinum Concentrator.
NEVER block the air openings of the product or place it on a
soft surface, such as a bed or couch, where the air opening
may be blocked. Keep the openings free from lint, hair and the
like.
DO NOT disassemble. The unit is provided with double
insulation and has no serviceable parts. Refer to ervicing of
Double-Insulated Products on page 11. If any service is
required, contact Invacare Technical ervice.
If the compressor has a damaged cord or plug, if it is not
working properly, if it has been dropped or damaged, or
submersed in water, call a qualified technician for
examination and repair.
Otros manuales para HomeFill II
4
Tabla de contenidos
Otros manuales de Compresor de aire de Invacare

Invacare
Invacare IOH200AW Manual de usuario

Invacare
Invacare IOH200 Manual de operación

Invacare
Invacare HomeFill II Manual de usuario

Invacare
Invacare HomeFillII AW Manual de usuario

Invacare
Invacare Envoy Manual de usuario

Invacare
Invacare Freeway Freedom IRC1175 Manual de usuario

Invacare
Invacare Envoy Jr. IRC1001 Manual de usuario

Invacare
Invacare 50 psi Compressor IRC607 Manual de usuario

Invacare
Invacare HomeFill II Manual de usuario

Invacare
Invacare HomeFill Oxygen System Manual de usuario