HWAM 3630 Manual de usuario

User's Manual EN
01.11.2020 / 97-9646
www.hwam.com
AUTOPILOT
3630 36503640 3660


Table of contents
Drawings ................................................. 4-8
Installation................................................ 9
Firing manual - wood ....................................... 13
Firing in general............................................ 16
Maintenance .............................................. 17
Operational problems....................................... 18
Declaration of Performance .................................. 18
Product information EcoDesign ............................... 19

Page 4 of 20 pages
A.
A1) A2)
1
2
3
4
34
1
1
2
3
4
5a
6
5b
B.
B1)
1
2
3
4
5a
6
5b
B2)

Page 5 of 20 pages
C.
1
2
3
5
4
6
6
7
8
9
11
12
10
C1)
C2)
E1)
E.
E2)
4
6
6
7
14
13
3
910
1
1

Page 6 of 20 pages
4
3
5
1
2
F.
10°
G.

Page 7 of 20 pages
6
5
4
1
2
3
8
7
910
6
5
4
1
2
3
8
7
910
H.

Page 8 of 20 pages
I

Page 9 of 20 pages
InstallatIon
In general
Congratulations on your new HWAM woodburning stove.We are pleased that you have chosen a HWAM
woodburning stove and confident that it will give you much pleasure.To ensure optimum operation and
safety, we recommend that the installation should be carried out by an authorised HWAM retailer or
a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under
“Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all European, national and
local building regulations.The installation must be carried out in accordance with the instructions in the
installation and user manuals and subsequently registered with the local authorities. Upon installation,
the chimney sweep must approve the installation before you can start using the woodburning stove.All
HWAM woodburning stove packaging material must be handled in accordance with local waste manage-
ment regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed. The
woodburning stove uses approx. 6-23 m3 of air per hour.A window that can be opened or an adjustable
air valve will be sufficient. It must not be possible to block the adjustable air valve/grate. In newly built/
airtight dwellings, we recommend that a fresh air system should be installed for the direct supply of
external air to the combustion.This fresh-air system may be bought separately.
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect 6,0 kW
Flue gas temperature EN 13240 measurement point 292ºC
Flue gas temperature measured in the outlet socket 350ºC
Exhaust gas flow 6,0 g/s
Efficiency 78,3 %
Annual efficiency (EcoDesign) 68,3 %
PM 18 mg/m3
OGC 66 mg/m3
NOx 94 mg/m3
CO at 13% O21125 mg/m3
CO at 13% O20,09 %
Energy efficiency index 104
Energy efficiency class A
Test result based on NS 3058
Particle emissions 1,21 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.

Page 10 of 20 pages
Model Weight Height Width Depth
HWAM 3630c/3630m 139/136 kg 114,8 cm 55,6 cm 44,2 cm
HWAM 3640c/3640m 139/136 kg 114,8 cm 55,6 cm 44,2 cm
HWAM 3640c/3640m with natural stone cladding 211/208 kg 114,8 cm 60,0 cm 44,2 cm
HWAM 3640c/3640m with soapstone cladding 229/226 kg 114,8 cm 60,0 cm 44,2 cm
HWAM 3650c/3650m 171/168 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3660c/3660m 171/168 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3660c/3660m w/heat-storing stone 260/257 kg 150,8 cm 60,0 cm 44,2 cm
HWAM 3660c/3660m w/soapstone cover 282/279 kg 150,8 cm 60,0 cm 44,2 cm
Heat storage stones, HWAM 3650+3660 55 kg
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a non-
combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM
retailer for assistance.The combustion chamber opening is 36.7 cm wide.
Distance to combustible materials
Min. distances - uninsulated flue gas pipe (drawing A) HWAM 3630
HWAM 3650
HWAM 3640
HWAM 3660
1. Recommended for brick wall, back, 10 cm 10 cm
2. Recommended for brick wall, side 15 cm 10 cm
1. For combustible back wall 10 cm 10 cm
2. For combustible side wall 40 cm 40 cm
1.To combustible wall,corner installation, 45º 35* cm 20* cm
3. Distance to furnishings in front, 90 cm 90 cm
*All dimensions in connection with corner installation are only recommendations. For UK: Please consult
a qualified and competent Installer for clarification.
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM®Autopilot™.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance.As a general
rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80
cm above the ridge. If the chimney is placed at side walls, the top of the chimney should always be higher
than the ridge or the tallest point of the roof.Always be aware of any national and/or local regulations
applying to thatched roofs and the location of the chimneys.
The woodburning stove requires a minimum draught of 1 Pa (measured at EN 13240 measurement point).
If measured just above the smoke flue socket, the chimney draught must be 17-19 Pa.
The chimney must have a minimum clearing of Ø 150 mm. The chimney must be provided with an
easily accessible cleaning door.The chimney and flue duct must be of flue class T400 and be CE marked.
Furthermore, it must have obtained the classification of G in soot fire testing.The required distance to
combustible material must be complied with in accordance with the brand label.Ask your HWAM retailer
for further information.
Otros manuales para 3630
3
Este manual sirve para los siguientes modelos
9
Tabla de contenidos
Otros manuales de Calentador de HWAM
Manuales populares de Calentador de otras marcas

Empire Heating Systems
Empire Heating Systems WCC65 Manual de usuario

Wetekom
Wetekom 92 86 43 Manual de usuario

Desa
Desa SPC170-F Manual de usuario

Watlow
Watlow Watrod Electric Tubular Heaters Manual de usuario

Haverland
Haverland ECO-DRY GPS Series Manual de lista de piezas

Stelpro
Stelpro ASILVC2060 Series Manual de usuario