Health Master Elite JLA-8 Manual de usuario

Owner’s
Manual
Do Not Operate The
HealthMaster Before
Reading This Entire Manual
FOR HOUSEHOLD USE ONLY.
Model: JLA-8
120 VAC 60Hz 1200W
SEE WARRANTY INFORMATION
IN THIS MANUAL
Also for red and white models.

2
Contents
Important Safeguards 3–4
Specications 4
Avoiding Serious Injury and Burns
While Processing Hot Liquids 4
Parts & Accessories 5
Assembling the HealthMaster™ 6–7
Controls 8
Using the Tamper 8
Using Your HealthMaster™ 9
Making Hot Soups/Sauce 9
Making Frozen Blends/Treats 9
Making Dough 10
Chopping with the HealthMaster™ 10
Cleaning and Maintenance 10–11
Troubleshooting 11
Frequently Asked Questions 12–14
Warranty Information 14
Replacement Parts Order Form 15

3
IMPORTANT SAFEGUARDS
IMPORTANT: Read this manual carefully and completely before attempting to
operate the HealthMaster. Failure to do so could result in serious personal injury.
• Blades are sharp. Handle carefully.
• Children should not be permitted to operate this, or any other kitchen appliance,
without the constant supervision of a qualied adult.
• Do not attempt any home repairs to this unit. Should the unit require repair, such
repair should only be performed by a qualied professional.
• Unit For Indoor Use Only. To reduce the risk of electric shock, never expose any
part of this appliance including the power cord, plug or motorized Base to rain,
moisture or immersion in liquids of any kind.
• The unit has a polarized plug. One prong is narrower than the other and it will
t only one way into an electrical outlet. Never force the plug into the outlet. If it
doesn’t t after trying it one way and then reversing it … contact an electrician.
Do not modify the plug in any way.
• Never use an adaptor or an extension cord.
• Never assemble, disassemble or handle the unit while it is plugged into an
electrical outlet. Keep unplugged when not in use.
• The HealthMaster comes equipped with a “Tamper” utensil. This is the only utensil
you should ever use while operating this unit. Using other utensils may damage
the unit and cause possible personal injury.
• To prevent overheating, do not block any ventilation intake openings (see page 5).
• Use on a dry, stable surface.
• When preparing fresh baby food always consult with your physician (pediatrician)
before making any dietary changes. Certain fruits and vegetables are not
recommended for infants or young children due to immature digestive systems,
allergies, or other developmental reasons.
• When preparing fresh baby food, to prevent choking, always make sure all fruits
and vegetables are completely liquied before feeding them to a baby.
• To avoid personal injury: Never remove the Lid while the motor is running. If
something is stuck press the power OFF button, wait for motor to stop running,
unplug the unit then remove the Cap only, insert the Tamper to dislodge stuck
food. If food remains stuck, disassemble and remove the blocked food.
• Make sure the Lid is attached properly before pressing the ON button.
• Avoid contacting moving parts.
• Do not operate any appliance with a damaged cord or plug or after the appliance
malfunctions, or is dropped or damaged in any manner. Return appliance to
the nearest authorized service facility for examination, repair or electrical or
mechanical adjustment.
• The use of attachments, including canning jars, not recommended by the
manufacturer may cause a risk of injury to persons.

4
SAVE THESE INSTRUCTIONS
IMPORTANT SAFEGUARDS (continued)
• Never use hands, ngers, or other utensils to insert food into the Pitcher.
Use the Tamper only.
• Never leave the HealthMaster unattended while motor is running.
• Never add ingredients to the HealthMaster while unit is running at a speed
of higher than #1.
• We do not recommend pressing the RUN button when the Pitcher is empty.
• Always use one hand to hold the Pitcher handle as this unit operates at
high speeds.
• Never put fruits with pits in the HealthMaster. Remove pits prior to placing items
into the Pitcher.
• The maximum capacity is 70 ounces. Use signicantly less with thicker ingredients.
• When processing foods with a dense consistency such as peanut butter, grains,
or doughs, do not process for more than 30 seconds at a time. Over processing
can cause the motor to overheat.
• Always make sure the Lid and E-Z Lock Cap are position before use.
• Do not let cord come in contact with stove, other hot surfaces or hang over
edge of table or counter.
WARNING Failure to follow these instructions can result in death,
re, or electric shock.
Specications Model: JLA-8 120 VAC 60Hz 1200W
Avoiding Serious Injury and Burns
While Processing Hot Liquids
• Make sure the Lid and E-Z Lock Cap are securely in place and locked when
processing hot liquids.
• When processing hot liquids always start on speed #1. Then increase rapidly to
the required speed for that recipe. Use caution when using hot liquids as steam
may escape from the sides of the E-Z Lock Cap.
• Always hold the Pitcher securely by the handle while processing hot liquids.

5
Parts & Accessories
IMPORTANT: Your HealthMaster has been shipped with the following components.
Check everything carefully before use. If any part is missing or has been damaged
in shipping do not use this product and contact shipper using the customer service
number located in the back of this owner’s manual.
Tamper
Non-Skid Feet
Bottom Air Vents (underside)
E-Z Lock Cap/Measuring Cup
Lid
Handy Tab
for easy open & close
Two Liter Pitcher
E-Z Grip Handle
Speed Buttons
Time
Buttons
LED Display
Weighted Safety Switch
ON/OFF Button
PULSE - RUN/STOP - ICE Buttons
Motor Housing Base

6
Assembling The HealthMaster™
WARNING: Do not plug power
cord into electrical outlet until unit
is fully assembled.
Unwind power cord to desired length.
This appliance was designed with built-in power
cord storage beneath the Base. Store the excess
length of cord neatly underneath to avoid
accidental tipping of machine while in use.
Power to unit will not take place
unless steps 1–5 in this section
are followed carefully.
1. Place the motor Base on
a stable, dry surface.
NOTE:
At this point you may want to place the ingredients for processing into the unit. Insert
ingredients into the Pitcher, soft foods rst, harder items last. The E-Z Lock Cap can be
removed during operation to add additional ingredients or to insert the Tamper. The
E-Z Lock Cap should only be removed at speed #1. Always replace Cap when you are
nished inserting Tamper or additional ingredients.
2. Firmly seat the Pitcher onto the
Base. The Pitcher will t on the Base
4 dierent ways. The 4 knobs on
the Base should t into the corners
under the Pitcher. Once seated
properly, this will activate the
weighted safety switch.
Figure A

7
Assembling The HealthMaster™ (continued)
NOTE: Unit will not turn on until Weighted Safety Switch is
fully engaged. Should the unit overheat during operation
the motor will automatically shut o. To restore power
allow the machine to cool down for 35 minutes.
NOTE:
While the power is ON and as air pressure
inside the Pitcher increases, steam will
release from the openings on the side of
the Cap. To release the steam, turn the Cap
counterclockwise to the unlock symbol.
5. Make sure the unit is assembled properly before
connecting the power cord to the electrical outlet. Once
the HealthMaster is plugged in, the ON/OFF button will
light up blue. But the LED Display will not be lit up. This
means the HealthMaster is not on but there is power.
6. BEFORE pushing the ON button — hold the top of the
assembled unit to prevent tipping when starting. Once
you push the ON button, the LED Display will illuminate.
7. After pushing the OFF button wait until the Blades
completely stop spinning and unit is unplugged before
removing the Cap, Lid, or the Pitcher.
4. Place Lid on Pitcher and push
down until Lid lip meets the top
of the Pitcher.
3. Insert the E-Z Lock Cap into the Lid
(aligning the Cap’s tabs with the Lid’s slots)
and turn clockwise to the lock symbol.
TABS

8
Using the Tamper
The Tamper is useful when preparing thick or frozen mixtures.
The Tamper can be used while the machine is running.
1. Make sure Lid is secure and locked in place.
2. Remove E-Z Lock Cap from Lid.
3. Insert Tamper through the opening in the Lid.
4. Hold the Pitcher handle with one hand,
grasp Tamper with the other hand.
5. Move up and down or in a circular motion
to move contents around the Blade.
Tips for Using the Tamper:
When preparing thick mixtures that don’t circulate freely, insert the
Tamper and move in a circular motion. This will help remove any air
or ingredients trapped by the Blade. The Lid prevents the Tamper
from making direct contact with the Blade.
NOTE: In the event the motor overheats during operation
it will automatically shut o. To restore power, allow it to
cool down for 35 minutes before using.
Controls
ON/OFF Button: Push once for ON. Push once for OFF.
The button lights up BLUE when the HealthMaster is
plugged in. It is ON when the LED Display is illuminated.
SPEED Selection: Use the (+) and (-) buttons
to select the speed, 1 through 8.
TIME: Use the (+) and (-) buttons to select the
amount of time in minutes, 0 through 10 minutes.
A time must be selected in order for it to run on
the RUN setting. If you have to blend for less
than 1 minute, manually stop the unit by
pressing the STOP button.
PULSE: Press and release to get a single burst
of speed for each pulse until you have achieved
the desired results. The button lights up BLUE
when activated.
RUN/STOP: Press RUN/STOP to start the
HealthMaster. If the speed was not set,
the HealthMaster will run at speed 1.
The button lights up BLUE when activated.
You must press RUN/STOP again to stop. A time must be selected
in order for it to run on the RUN setting. If you have to blend for less
than 1 minute, manually stop the unit by pressing the STOP button.
ICE: Pressing the ICE button causes the HealthMaster
to operate on a cycle of 1 second on and 4 seconds o.
The button lights up Blue when activated. Press ICE
again to stop.
Attention: The unit will not run on the RUN setting unless a time is selected. If you have
to blend for less than 1 minute, manually stop the unit by pressing the STOP button.

9
Using Your HealthMaster™
• Always remove all stems and large pits such as peach, mango, apricot, etc.
before processing as these items can damage the Blade and cause the motor to
malfunction.
• Unless otherwise instructed, insert wet ingredients into the HealthMaster™ rst,
then dry ingredients, then ice if needed.
• Thoroughly wash all fruits and vegetables before juicing to remove any dirt
or chemicals.
• Fruits and vegetables juice best when they are fresh and rm.
• Always serve fresh foods immediately. After just a few seconds they begin to lose
vitamin potency.
Making Hot Soups & Sauces
1. Carefully add liquids and solids, avoiding splashing that could cause personal
injury when liquids are hot. (When recipe calls for hot liquid to be added to the
Pitcher, let sit for 3–5 minutes with the E-Z Lock Cap removed, allowing the steam
to escape.)
2. Secure Lid and E-Z LOCK Cap on the Pitcher making sure Cap is in the
locked position.
3. Push the ON control button and then the RUN button.
4. Slowly increase the speed control from #1 to #8 (as specied by the recipe). Let
the machine run until desired consistency or temperature has been reached. The
average cook time is 6–8 minutes on speed #8. This will vary depending on the
texture of the ingredients and the starting temperature.
5. Do not remove Lid and E-Z LOCK Cap until the power is OFF and the unit has been
unplugged. Wait for motor to shut o and the Blades to completely stop.
6. To open Lid, rst remove the E-Z LOCK Cap to let steam escape then remove Lid.
Pureeing Cooked Soups & Sauces
1. Carefully add hot soup or sauce, avoiding splashing that could cause personal
injury. Let sit for 3–5 minutes with the E-Z Lock Cap removed, allowing the steam
to escape before blending.
Making Frozen Blends & Treats
1. To make ice cream and sorbet, add liquids and soft ingredients (i.e. soft fruits)
rst, then frozen ingredients. In order to make successful frozen treats with the
HealthMaster you must always follow the recommended ratio of ingredients.
1 part liquid to 3–4 parts frozen ingredients. Changing this ratio can damage the
Blades or the motor.
2 . Place the Lid on securely. Remove E-Z LOCK Cap from Lid and insert Tamper.
NOTE: You will need to use the Tamper to move ingredients around quickly.
3. Press ON button. Press RUN button. Increase the speed to #8 (high) and blend
to desired consistency.

10
Chopping with the HealthMaster™
The HealthMaster chops food to a ne texture quickly and easily for use in
salads, soups, and baking:
1. Place ingredients in the Pitcher. Do not ll more than 1/4 full.
We recommend using smaller pieces when chopping.
2. Secure Lid and Cap then select ON button.
3. Set to recommended speed.
4. Use the PULSE button until all ingredients have been processed.
NOTE: The speeds may vary depending on the ripeness of ingredients when
using fresh fruits and vegetables.
• Broccoli #3 –4
• Cauliower #3 –4
• Zucchini/Squash #3–4
• Hard Boiled Eggs #3 –4
• Olives #2–3
• Potatoes #2–3
• Onions #2–3
• Nuts #3
• Carrots #3 –4
• Mushrooms #2–3
• Breadcrumbs #2–3
Recommended Speed Settings For Chopping
Cleaning and Maintenance
1. Press OFF button and wait until the motor completely stops.
2. Using dry hands, unplug the power cord from electrical outlet.
3. Disassemble the machine.
4. Wash the Lid and Cap in warm soapy water. Rinse and dry thoroughly before
rst use.
5. NOTE: DO NOT put unit in dishwasher. We recommend washing the Pitcher
by hand. For safety reasons, do not touch the blade directly with your ngers.
Fill the Pitcher with warm soapy water. Attach the Pitcher to the Base. Then
secure the Lid and Cap in place. Press ON button. Increase the speed to 8.
Then press the RUN button. Allow it to run for about 1 minute. Rinse and dry
thoroughly.
Making Dough
1. To make dough for fresh bread or pizza, add the dry ingredients into the
Pitcher rst. Secure the Lid without the Cap.
2. Press ON button. Increase the speed to 4. Press RUN button. Add the wet
ingredients into the Pitcher while the motor is running. Allow it to run for 5-8
seconds only. Press STOP button.
3. Increase the speed to 8. PULSE approximately 20 times until the mixture
becomes a crumbled texture. Press OFF button.
4. Remove the Lid and Pitcher. Pour the dough into a bowl. Turn the gear end of
the Blade under the Pitcher to get all the dough out.
5. Knead the dough into a ball on a oured surface. Place the dough back into a
covered bowl. Let the bowl and dough sit in a warm place for approximately
45 minutes or until doubled in size.
6. Divide dough into pieces to bake bread, pitas, pizza and more.
Tabla de contenidos
Otros manuales de Licuadora de Health Master