Harvest TEC 600 Manual de usuario

010-0600-OPR
10/14
Operation Manual
Model 600
Moisture Sensor Kit for Large Square Balers
Forage Harvester

2
(intentionally blank)

3
Harvest Tec Model 600 Operations Table of Contents
PAGE
Introduction
System Requirements
4
4
Safety
Safety Decals
5
5
Connecting Power and Communication Harness
6
Operation of the ISOBUS Monitor
6
Descriptions of Screens and Menus for the ISOBUS Monitor
7-13
Automatic Mode
8
Manual Mode
9
Diagnostics
10
Setup Mode
11-12
Job Records
13
Setting up Application and Bale Weight Parameters
14-15
Application Rate Setup
14
Baling Rate Setup
15
Operating Instructions
16
Automatic mode
16
Manual mode
17
Diagnostics
18
Job Records
19
Maintenance
20
Dielectric grease connections
21
Battery connections
21
Winter Storage
21
Status Alerts
21
600 Series Harnesses/Wiring Installation and Diagram
22
Pin Outs for Harnesses and Wiring Diagram
23-24
Common Questions
25
Troubleshooting
26
Parts Breakdown
27-28
Star wheel sensors
27
Control boxes and wiring harnesses
28
Optional Touch Screen Display (TSD)
29
Large Square Template
30
Notes
31
Warranty statement

4
Introduction
Thank you for purchasing a Harvest Tec Model 600 Moisture Monitor System. This 600 Moisture Monitoring
System has been designed to plug directly into most tractors that have an ISOBUS Monitor. If you do not have
one you may need to order the Touch Screen Display (TSD 030-5670A). The 600 Moisture Monitoring System
offers these advantages;
1. Operation coordinated with baler operation
2. Less cab clutter providing better visibility
3. Ease of use with all information on one screen
4. Records kept together
5. And the system is ready for future updates.
The 600 Moisture Monitor kit includes the following parts: Dual Channel Processor (DCP), Moisture Sensors,
Harnesses and Miscellaneous Hardware. For your convenience a parts break down for the 600 Moisture
Monitor System is included in the back of this manual. If you do have questions please bring this manual into
the dealership. They can assist you in ordering the correct replacement parts.
Right and Left sides are determined by facing in the direction of forward travel.
System Requirements
If your tractor does not have an ISOBUS Monitor
you will need the Touch Screen Display
PN 030-5670A
Attention:
For kits on 2010 Krone HDP balers Krone part number 20 073 194 0 must be ordered to mount the starwheels.
Please see attached supplemental manual for further instructions.

5
Safety
Carefully read all the safety signs in this manual and on the applicator before use. Keep signs clean and
visible. Replace missing or damaged safety signs. Replacement signs are available from your local
authorized dealer. See your installation manual under the replacement parts section for the correct part
numbers.
Keep your applicator in proper working condition. Unauthorized modifications to the applicator may impair the
function and/or safety of the machine.
Carefully read and understand all of the baler safety signs before installing or servicing the baler. Always use
the supplied safety equipment on the baler to service the applicator.
Safety Decals
Number 1
Disconnect power before servicing.
Part no. DCL-8003
Number 2
Read and understand the operator’s manual
before using or working around the equipment.
Part no. DCL-8000

6
Connecting Power and Communication Harness
The harnesses are located at the front of the baler near the hitch and at the back of the tractor near the
drawbar. See arrow below. Make sure all connection wires are free between the hitch of the baler and the
back of the tractor, especially when tractor is turning away.
WARNING: Stop tractor engine and shift to park or neutral, set brakes and remove key before leaving
the tractor.
Operation of the ISOBUS Monitor
The ISOBUS Monitor selections are made utilizing a combination of soft keys, number menus, or a scroll wheel
on the upper right side of the actual monitor to make selections depending on which ISOBUS Monitor you
have.
At any time after the initial Start Up/Power On the Uploading Data status bar should begin to fill. Please refer
to your ISOBUS Monitor manual to verify how this upload is displayed.
Once the upload has completed the operator can toggle between the tractor display and the Harvest Tec
functions by pushing the Next Implement key. This key may have circling arrows or arrows forming a triangle.

7
Description of Screens and Menus for ISOBUS Monitor
This system is calibrated for use with Harvest Tec buffered propionic acid. The use of other products can
cause application problems and damage to system components. It is designed to apply rates of 44 to 632
pounds of acid per hour and read moisture levels of 6 to 70 percent. The 665 monitor will allow you to set your
bale size, weight, single bale formation time, moisture levels and application rates. The Automatic Mode will
automatically adjust the application rates as the moisture level changes. Manual Mode will allow you to control
the application rates on the go.
Listed below are the Main Menu Options.
Automatic Mode ( 1 ) This operating mode automatically adjusts preservative application as you bale. The
following items are displayed in the mode while baling: Moisture, Baling Rate, Application Rate (actual and
target), Last Bale Average Moisture, Tons Baled, and Pounds of Product Used.
Manual Mode ( 2 ) This operating mode allows the three different pumps to be turned on at a fixed rate as you
bale. The following items are displayed in the mode while baling: Moisture, Baling Rate, Application Rate
(actual only), Last Bale Average Moisture, Tons Baled, and Pounds of Product Used. This mode can also be
used to prime the pumps.
Diagnostics ( 3 ) Allows operator to set the date and time. The installed software versions can also be
viewed here.
Setup Mode ( 4 ) This mode allows the operator to customize the applicators settings for their baler and
baling needs. This mode allows changes to be made to the following areas: Application Rate, Baling Rate,
Language, US or Metric units, and turn on/off the optional Hay Indicators.
Job Records ( 5 ) Keeps track of up to 300 plus jobs with total product used, average moisture content,
highest moisture content, tons baled, date of baling, and total number of bales made. Individual bales are also
able to be viewed and the records can also be downloaded to a USB drive in this mode.
Main Menu for the Hay Preservative

8
Screen Menus
Use the below listed screen menus to navigate through all of the operation screens. Navigation through the
screens is accomplished by using the touch screen of the controller and pressing.
Automatic Mode:

9
Manual Mode:
Diagnostics:

10
Diagnostics: