Quickstart Guide

1
GC-IMS-ODOR – Quickstart Guide
Version 1.4.1, April 2021
Valid for GC-IMS-ODOR Firmware- Version 4.0 and higher
All data, texts, designs, images and other elements used in this user manual are
protected by copyright law. Any infringement may be subject to legal action.
Passing it on to third parties and producing copies of any kind or form –on the
whole or in parts - is not permitted without written agreement of G.A.S. Any
infringement may be subject to legal action.
G.A.S. reserves the right to realize technical changes to the product without
explicitly mentioning them.
CE-Marking according to:
International Standard EN ISO 17050-1:2004
European Union Low Voltage Directive 2006/95/EC
European Union Electromagnetic Compatibility Directive 2004/108/EC
© Copyright 2015-2020
G.A.S. Gesellschaft für analytische Sensorsysteme mbH
44227 Dortmund - Germany
Kontakt:
G.A.S. Gesellschaft für analytische Sensorsysteme mbH
44227 Dortmund –Germany
Telefon: +49 (0) 231 / 97 42 - 65 50
Fax: +49 (0) 231 / 97 42 - 65 55
Please have the serial-number of the instrument at hand

2
Table of Content:
1General Information .......................................................................... 3
1.1 Information about the Manual ...................................................... 3
1.2 Explanation of Symbols .............................................................. 4
1.3 Notation for dialogs, elements and references .................................. 4
1.4 Scope of Supply ....................................................................... 6
1.5 Liability and Guarantee.............................................................10
1.6 Copyright .............................................................................10
1.7 Return and Disposal .................................................................11
1.8 Software Updates....................................................................11
1.9 Customer Service ....................................................................11
2Safety ..........................................................................................12
2.1 Intended Use Only ...................................................................12
2.2 Responsibility of Operator..........................................................13
2.2.1 Requirements of Personnel ............................................................... 13
2.2.2 Dangers ...................................................................................... 14
3Transport, Packing and Storage ............................................................15
3.1 Inspection after Transport .........................................................15
3.2Packing ................................................................................15
3.3 Storage and Transport ..............................................................16
4Cleaning and Maintenance ..................................................................17
4.1 Cleaning...............................................................................17
4.1.1 Maintenance ................................................................................ 17
5Installation GC-IMS Device ..................................................................18
5.1 Installation Requirements ..........................................................18
5.2 Set-up of the GC-IMS-Odor Instrument ...........................................20
5.3 Workflow Cleaning ..................................................................23
5.4 Workflow Selecting the Application Mode .......................................24
5.5 Workflow: Define Tag Lists (optional) ............................................25
5.6 Workflow: Set the Output of the Current Loop (optional).....................27
6Running the instrument .....................................................................29
6.1 Preparations for Measuring.........................................................29
6.2 Workflow: Run a Manual Measurement ...........................................31
6.3 Workflow: Run a Manual Calibration..............................................33
6.4 Workflow Running automated Measurements ...................................35
6.4.1 Introduction to the Interval Mode........................................................ 35
6.4.2 Defining automatic measurement schedule ............................................ 36

3
1General Information
1.1 Information about the Manual
INFORMATION!
This Quickstart User Manual is an extract of the most
important information for installation and initial setup
from the User Manual. It is an addition to the User Manual
and does not replace the User Manual.
This manual describes a safe and adequate handling of the device. Following the
instructions of the indicated safety aspects and instructions as well as the national
and/or local rules and general safety regulations concerning the prevention of
accidents are absolutely imperative.
Before starting the work with the device read the manual completely and
thoroughly particularly the chapter security and respective safety references.
Assure that you/the operator comprehend the terms described.
The manual is part of the device. It must be stored together with and next to the
device at any time.
INFORMATION!
The graphics in this user manual are schematic and may
differ from the actual conditions. The firmware and PC
software screenshots in this user manual may differ from
the actual conditions.

4
1.2 Explanation of Symbols
Important and safety-relevant references in this manual are characterized by
symbols. These indications which are in-line with industrial safety must be
respected and followed at any time.
INFORMATION
This symbol calls information, which are to be considered
for efficient and perfect handling of the equipment.
WARNING
This symbol indicates references, which can lead to
damages, malfunctioning and/or loss of the device.
DANGER
This symbol marks references, which can lead to health
impairments, injuries, lasting body damages or to death
due to electric current.
DANGER
This Symbol marks paragraphs, which describe potential dangers and
damage due to exposure to radioactive radiation.
1.3 Notation for dialogs, elements and references
Example Dialog:
System ›Connections ›LAN File Transfer ›Settings… ›Test Connection
Example Elements:

5
Gas Out, Sample gas in
Example: References
Advanced User Manual, Chapter 5.1 Installation Reguirements
Example: Information
keep the transport box

6
1.4 Scope of Supply
Assure that you have received the full scope of supply. If there is any part missing,
please contact the GAS-hotline immediately.
Standard Scope of Supply
GC-IMS-Odor Device (1 piece)
Power supply (1 piece)
GC-IMS Gas tube Kit
•Driftgas/Carriergas (1 piece)
•2 m 3mm PFA Tubes with 3
mm Swagelok-Connector (6
Pieces)
•Bypass Adapter (1 piece)

7
Molecular sieve 200 ml with 1/8”
connections (1 piece)
LAN Cable (1 piece)
GC-IMS Blind plug Set (5 pieces)
(Swagelok 3mm Blind plug with red
cap installed on device connectors)

8
Torx Tool Kit
•Torx Srewdriver 8 mm (1
piece)
•Torx Srewdriver 10 mm (1
piece)
I/O Connector (1 piece)
Document Map with Documents and
Device User Manuals
USB-Stick Box with Software und
Documents (1 piece)

9
Transport box (1 piece)
GC-IMS Transport palett (60 x 80
cm)
Optional Scope of Supply (only available if ordered)
Nitrogen Generator with accessories
(example picture)
Tabla de contenidos
Otros manuales de Instrumento analítico de GAS
Manuales populares de Instrumento analítico de otras marcas

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instrucciones de instalación y funcionamiento

RIDGID
RIDGID SeeSnake Compact Manual de usuario

Teledyne
Teledyne 3000PA Manual de usuario

YDLIDAR
YDLIDAR TIA Manual de usuario

Olympus
Olympus IPLEX FX Series Manual de usuario

Bosch
Bosch GLM 50 C Professional Manual de usuario