FLIR Raymarine CPT-90DVS Manual de usuario

CPT-90DVS/CPT-100DVS
Installationinstructions
Warning:Productinstallationand
operation
•Thisproductmustbeinstalledandoperatedin
accordancewiththeinstructionsprovided.Failure
todosocouldresultinpersonalinjury,damageto
yourvesseland/orpoorproductperformance.
•Raymarinerecommendscertiedinstallation
byaRaymarineapprovedinstaller.Acertied
installationqualiesforenhancedproduct
warrantybenets.ContactyourRaymarinedealer
forfurtherdetails,andrefertotheseparate
warrantydocumentpackedwithyourproduct.
Warning:Highvoltages
Thisproductmaycontainhighvoltages.DoNOT
removeanycoversorotherwiseattempttoaccess
internalcomponents,unlessspecicallyinstructed
inthedocumentationprovided.
Warning:Switchoffpowersupply
Ensurethevessel’spowersupplyisswitchedOFF
beforestartingtoinstallthisproduct.DoNOT
connectordisconnectequipmentwiththepower
switchedon,unlessinstructedinthisdocument.
Caution:Serviceandmaintenance
Thisproductcontainsnouserserviceable
components.Pleasereferallmaintenance
andrepairtoauthorizedRaymarinedealers.
Unauthorizedrepairmayaffectyourwarranty.
Caution:Transducercable
•DoNOTusethetransducercabletoliftor
suspendthetransducer;alwayssupportthe
transducerbodydirectlyduringinstallation.
•DoNOTcut,shorten,orsplicethetransducer
cable.
•DoNOTremovetheconnector.
Ifthecableiscut,itcannotberepaired.Cutting
thecablewillalsovoidthewarranty.
Caution:Productcleaning
Whencleaningproducts:
•Lightlyrinseorushwithclean,coolfresh
water.
•Ifyourproducthasadisplayscreen,doNOT
wipethescreenwithadrycloth,asthiscould
scratchthescreencoating.
•DoNOTuse:abrasive,acidic,ammonia,
solventofchemicalbasedcleaningproducts.
•DoNOTuseajetwash.
Partssupplied
1.Mountingbracket
2.Ratchetarm
3.M5Hexratchetbolt
4.Ratchetplate
5.Compressionwasher
6.M5washer
7.M5lockingnut
8.*Escutcheon(forthrough-transomcablerouting),plus2
screws
9.*P-clipsand3screws
10.Documentation
11.Transducerwithcable
Note:*NOTsuppliedwithCPT-90DVSvariant.
Selectingalocationforthetransducer
Thisproductissuppliedwithatransommounttransducer.The
guidelinesbelowshouldbefollowedwhenselectingalocation
forthetransducer.
Note:Thetransducerisnotsuitableformountingonvessels
wherethetransomisaftofthepropeller(s).
Forbestperformancethetransducermustbeinstalledina
locationwiththeleastturbulenceandaeration.Themosteffective
waytodeterminethisisbycheckingthewaterowaroundthe
transomwhilstunderway.
•Mountclosetothekeel(centerline),inapositionwherethe
transducerelementwillbefullysubmergedwhenthevessel
isplaningandturning.
•Mountasuitabledistancefromthepropeller(s)toavoidwake.
•Forclockwiserotatingpropellers,mountthetransduceronthe
starboardside,forcounter-clockwise,mountontheportside.
•Onatwinenginevesselmountthetransducerbetweenthe
engines.
•Turbulencecanbecausedbyanumberofotherfactorssuch
assteps(1),ribs(2),rowsofrivets(3)andstrakes(4).The
turbulenceappearsaftoftheselocations.
Documentnumber:88065-2AA;3945;2017-05-11T09:30:39Date:05-2017

•Airtrappedunderthefrontofthevesselcantravelunderthe
hullandappearasaerationaft.
•Ifinstallingonthestepofasteppedtransom,allowsufcient
roomabovethetransducerfortransducerkickup.
Note:Optimumtransducerlocationwillvarydependingon
vesseltype.Optimumtransducerheightandangleshould
beobtainedbytestingthetransducerwiththevesselin
thewater.
Productdimensions–CPT-DV/CPT-DVS/
CPT-100DVS/CPT-90DVS
Thetransducer’sdimensionsincludingthetransommounting
bracketareshownbelow.
•TheCPT-DVcablelengthis4m(13.1ft.)
•TheCPT-DVScablelengthis6m(19.7ft.)
•TheCPT-90DVScablelengthis6m(19.7ft.)
•TheCPT-100DVScablelengthis10m(32.8ft.)
Cablerouting
Cableroutingrequirementsforthetransducercable.
Important:Toavoidinterference,thecablemustberoutedas
farawayfromVHFradioantennacablesaspossible.
•Thecablecanberoutedthroughoroverthetransom.
•Checkthatthecableislongenoughtoreachtheequipment
thatitwillbeconnectedto.Anoptional4m(13.1ft)extension
cableisavailableifrequired.
•Ensurethereisenoughslackinthetransducercable,atthe
transducerend,toallowthetransducertopivotupanddown.
•Securethecableatregularintervalsusingcableclips.Please
note,cableclipsarenotsuppliedwithalltransducervariants.
•Fillalltransommountingholeswithmarine-gradeneutralcure
polyurethanesealantpriortotighteningsecuringscrews.
•Fillthetransomcableholewithmarine-gradeneutralcure
polyurethanesealantafterroutingthecable(ifroutingthrough
thetransom).
•Useanescutcheontocoveroverthetransomcablehole(if
routingthroughthetransom).Pleasenote,anescutcheonis
notsuppliedwithalltransducervariants.
•Anyexcesscablecanbecoiledupataconvenientlocation.
Note:DoNOTusesealantscontainingacetateorsilicone,
whichcancausedamagetoplasticparts.
Maximumtransducercablelength
Themaximumrecommendedcablelengthfromthetransducerto
theunitisshownbelow.
CPT-DV8m(26.2ft.)—4m(13.1ft.)
suppliedcable+4m(13.1ft.)
extensioncable
CPT-DVS10m(32.8ft.)—6m(19.7ft.)
suppliedcable+4m(13.1ft.)
extensioncable
CPT-90DVS10m(32.8ft.)—6m(19.7ft.)
suppliedcable+4m(13.1ft.)
extensioncable
CPT-100DVS14m(45.9ft.)—10m(32.8ft.)
suppliedcable+4m(13.1ft.)
extensioncable
Note:Extendingthetransducercablebeyondthemaximum
statedlengthwillcausepoorperformance.
Mountingthetransommountbracket
Thetransducermustbemountedonthetransomusingthe
mountingbracketprovided.Thestepsbelowdescribethe
initialmountingstepsrequiredinordertotestyourtransducers
performance.Aftertestingthetransduceryoumustnishthe
mountingfollowingtheinstructionsintheFinishingthetransducer
mountingsection.
1.Fixthetransducermountingtemplatetotheselectedlocation,
usingmaskingorself-adhesivetape.
1Transducermountingtemplate
2Waterline
3Mountingawayfrompropeller
2.Ensurethetemplateisparalleltothewaterline.
3.Drill2xholesfortheadjustmentslotscrewsasindicatedon
thetemplate.
Note:DoNOTdrillthethirdmountingholeatthisstage.
2CPT-90DVS/CPT-100DVSInstallationinstructions

4.Fillthe2holeswithmarinegradesealant.
5.Usingapozi-drivescrewdriverandthescrewsprovided,
securethetransommountbracketusingthe2adjustment
slots.
Note:Thethirdlockingscrewisnotuseduntilthetransducer
hasbeensuccessfullytested.
Mountingthetransducer
Thetransducermustbemountedonthetransomusingthe
mountingbracketprovided.Thestepsbelowdescribethe
initialmountingstepsrequiredinordertotestyourtransducers
performance.Aftertestingthetransduceryoumustnishthe
mountingfollowingtheinstructionsintheFinishingthetransducer
mountingsection.
1.Feedthetransducercablebetweenthepostsonthemounting
bracketasshown.
2.Slidetheratchetarmintotheguideonthetopofthe
transducer,ensuringitlocksinplace.
3.Holdtheratchetplateinplaceontheratchetarmasshown.
4.Inserttheratchetarmbetweenthemountingbracketposts,
aligningthecenterholewiththeholesintheposts.
5.SlidetheM5washerandthenthecompressionwasheronto
theratchetbolt.
6.Slidetheratchetboltthroughthemountingbracketassembly.
7.InserttheM5lockingnutintothecaptivehousingonthe
mountingbracket.
8.Usinga4mmHexwrench(allenkey)tightentheratchet
boltuntiltheratchetmechanismisengagedbutcanstillbe
adjustedbyhand.
9.Positionthetransducersothatthebottomfaceofthe
transducerwillbeparallelwiththewaterlineandtightenthe
ratchetbolt.
Thetransducerpositionwillbeadjustedfurtherduringtesting.
Testingandadjustingthetransducer
Oncetheinitialmountingprocedureshavebeencarriedout,the
transducermustbetestedpriortonishingthemounting.
Thetestingshouldbecarriedoutwithyourvesselinthewater,
withadepthgreaterthan0.7m(2.3ft)butlessthanthemaximum
depthrangeofthetransducer.
Important:TheSonarchannelwillbeabletomaintain
readingsathighervesselspeedsandatgreaterdepthsthan
theDownVision™application.
1.PressandholdthePowerbuttontopowertheuniton.
2.CompletetheStart-upwizardandtutorial.
3.Opentherelevantapplication.
Thebottomshouldbevisibleonscreenandadepthreading
displayed.
4.Startmovingyourvesselatalowspeed,ensuringyouhavea
depthreadingandaclearimageisdisplayed.
5.Graduallyincreasethevesselspeedwhilstcheckingthe
display,iftheimagebecomespoororthebottomismissingat
lowerspeedsthenthetransducerneedstobeadjusted.
6.Angleandheightadjustmentsshouldbemadeinsmall
incrementsandre-testedeachtimeuntilyouobtainoptimum
performance.
7.Loosentheratchetarmbolttoadjustthetransducerangle.
8.Loosenthe2mountingbracketscrewstoadjustthetransducer
height.
9.Re-tightentheratchetarmboltandmountingscrewsbefore
re-testing.
Note:
•Itmaynotalwaysbepossibletoobtaindepthreadings
athigherspeedsduetoairbubblespassingunderthe
transducer.
•Itmaybenecessarytomakeseveraladjustmentstothe
transducerbeforeobtainingoptimumperformance.
•Ifthetransducerrequiresrepositioningensurealloldholes
arelledwithmarinegradesealant.
Removingthetransducer
Thetransducercanbereleasedfromthebracketbyinsertinga
smallmetalrodsuchasapaperclipintothetransducerrelease
holelocatedasshown.
CPT-90DVS/CPT-100DVSInstallationinstructions3

1.Insertthemetalrodintothetransducerreleasehole.
2.Slidethetransduceroffofthebracket.
Finalizingthetransducermounting
Onceyouhaveachievedoptimumperformanceatthedesired
vesselspeedsthetransducermustbelockedintopositionto
completetheinstallation.
1.Drillthelockingholelocationtakingcarenottodamagethe
mountingbracket.
2.Fillthelockingholewithmarinegradesealant.
3.Securethetransducerandbracketbyfullytighteningall3
mountingscrews.
4.Securetheratchetarmbolt,bytighteninguntilthe
compressionwasheriscompressedandthenaddanother1/4
turn.Ifthetransducerkicksupatspeedthentightenfurther.
Important:Takecaretoensurethatthepivotboltisnot
overtightenedasthiswillpreventkick-upandmaycause
damage.
4CPT-90DVS/CPT-100DVSInstallationinstructions
Este manual sirve para los siguientes modelos
1
Otros manuales de Transductor de FLIR
Manuales populares de Transductor de otras marcas

Mianyang Weibo Electronic
Mianyang Weibo Electronic WB Series Manual de usuario

ProMinent
ProMinent Dulcometer DMT Manual de usuario

MKS
MKS MicroPirani 925 Series Cómo utilizar

WIKA
WIKA WU-20 Manual de usuario

Alcatel Vacuum Technology
Alcatel Vacuum Technology BARATRON 622A Manual de usuario

Camille Bauer
Camille Bauer SIRAX CH-5610 Manual de usuario