ProMinent Dulcometer DMT Manual de usuario

ProMinent®
Cl
ppm
Cl
12.5 mA 21.0 °C
0.20
Part no. 987395 ProMinent Dosiertechnik GmbH ·69123 Heidelberg ·Germany BA DM 107 12/03 GB
Please read the operating instructions through completely before
commissioning this equipment! ·Do not discard!
Any part which has been subject to misuse is excluded from the warranty!
Operating Instructions
DULCOMETER®DMT
On-site measurement transducer
Measured variable chlorine
only for DMT measuring cells
Please enter the identity code for your device here!
DMTa ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___

Page 2 ProMinent®
Publishing details
Publishing details:
Operating Instructions
DULCOMETER®DMT on-site measurement transducer
Measured variable chlorine
© ProMinent Dosiertechnik GmbH, 2000
Address:
ProMinent Dosiertechnik GmbH
Im Schuhmachergewann 5-11
69123 Heidelberg · Germany
Postfach 101760
69007 Heidelberg · Germany
Tel.: +49 (6221) 842-0
Fax: +49 (6221) 842-419
www.prominent.de
Subject to technical alterations.

ProMinent®Page 3
Table of contents
Device identification/identity code chlorine ..................................................... 5
General instructions for use ................................................................................. 6
1About this device ......................................................................................................... 7
2Safety ................................................................................................................................... 7
2.1 Correct use ........................................................................................................... 7
2.2 Safety guidelines ............................................................................................... 7
3Storage and transport .............................................................................................. 7
4Assembly and installation ...................................................................................... 8
4.1 Assembly (mechanical) .................................................................................. 8
4.1.1 Wall mounting ..................................................................................................... 8
4.1.2 Pipe mounting ..................................................................................................... 9
4.1.3 Panel mounting .................................................................................................. 10
4.2 Installation (electrical) ..................................................................................... 11
4.2.1 Wall mounting ..................................................................................................... 12
4.2.2 Pipe mounting ..................................................................................................... 13
4.2.3 Panel mounting .................................................................................................. 13
4.2.4 Connecting terminals ...................................................................................... 14
5Device overview and control elements ......................................................... 15
6Function description .................................................................................................. 16
6.1 General ................................................................................................................... 16
6.2 Key functions ...................................................................................................... 17
6.3 Operating menu, schematic ........................................................................ 17
6.4 Negotiating operating menu ....................................................................... 18
6.4.1 Calibration menu ............................................................................................... 19
6.4.2 Info-Display .......................................................................................................... 19
6.4.3 Menu options ...................................................................................................... 19
6.4.4 Negotiating the menu options ................................................................... 19
Table of contents

Page 4 ProMinent®
7DMT settings ................................................................................................................... 20
7.1 Measured variable chlorine ......................................................................... 21
7.1.1 Menu overview: Measured variable chlorine...................................... 21
7.1.2 Parameter measurement .............................................................................. 22
7.1.3 Parameter temperature .................................................................................. 22
7.1.4 Parameter output .............................................................................................. 24
7.1.5 General settings ................................................................................................. 26
8Operating the DMT ..................................................................................................... 28
8.1 Permanent display............................................................................................ 28
8.1.1 Brightness of LC display ............................................................................. 28
8.2 Calibration............................................................................................................. 28
8.2.1 The calibration process ................................................................................. 28
9Troubleshooting ............................................................................................................ 31
9.1 Error messages during operation ............................................................. 31
9.2 Error messages during calibration........................................................... 32
10 Maintenance and repair ........................................................................................... 33
11 Disposal .............................................................................................................................. 33
12 Technical data ................................................................................................................ 34
13 Spare parts and accessories ............................................................................... 35
Appendix
Declaration of conformity ........................................................................................... 36
Terminal connection plan chlorine ........................................................................ 37
Wiring example - two wire system ........................................................................ 38
PROFIBUS®circuit board terminal connection .............................................. 39
Index ...................................................................................................................................... 40
Drilling template for DMT ........................................................................................... 43
Table of contents

ProMinent®Page 5
Device identification/identity code: measured variable chlorine
Please enter the identity code for your device here!
DMTa
DMTa DULCOMETER®DMT series measurement transducer
Mounting type
Wwall/pipe mounted
Scontrol panel mounted (not PROFIBUS®-DMT)
Version
0with ProMinent logo
Electrical connection
94-20 mA two wire
5PROFIBUS®-DP, 24 V DC (16...30 V DC)
Communication interface
0none
4PROFIBUS®-DP
Measured variable
Cchlorine
Correction variable
0none
1temperature (Pt 1000/Pt 100)
Enclosure rating
0standard
Adjustable via general settings:
Language
DGerman
EEnglish
FFrench
SSpanish
IItalian
Chlorine measuring cell type
0CLE 5 ppm
4CTE 10 ppm
5CLE 50 ppm
Temperature measurement
0automatic
(Pt 1000 or Pt 100)
1manual
2automatic or manual
Output
0measured variable
(fault: 23 mA, calibration: 23 mA)
1manually adjustable
current value
2measured variable or manual
(fault: 23 mA, calibration: 23 mA)
3measured variable or manual
(fault: 23 mA, calibration: HOLD)
44mA constant current
Other settings
0standard

ProMinent®
Page 6
General instructions for use
Please read through these instructions for use carefully! They will enable you
to make the best possible use of this operating instructions manual.
The following sections are highlighted in the text:
•Enumerated points
왘Instructions
Working instructions:
NOTE
Guidelines are intended to make your work easier.
and safety instructions:
CAUTION
Describes a potentially dangerous situation.
Non-observance can lead to personal injury or damage
to property!
IMPORTANT
Describes a potentially dangerous situation.
Non-observance can lead to damage to property.
General instructions for use

Page 7
ProMinent®
1About this device
The measurement DULCOMETER®DMT for conductive conductivity is a two-
wire measurement transducer for use in all areas of process and process
technology in non-explosive areas.
It shows the electrolytic conductivity and/or specific resistance and produces
a proportional output signal.
An optimum PROFIBUS®-DP interface enables e.g. read out of the measure-
ment, correction and calibration values of the measurement transducer by a
PC or PLC and provides a superseding system.
PROFIBUS®-DP is a manufacturer-independent interface.
2Safety
2.1 Correct use
The DMT on-site measurement transducer is designed exclusively for the
•measurement of chlorine concentration
•measurement of temperature
•display of measured variables
•production of an output signal
•for the connection of DMT probes
It is prohibited to use the device for any other applications or to modify it in
any way!
Do not use the device out of doors without additional protection (protective
housing, weatherproof cover).
The DMT measurement transducer is not suitable for use in explosive areas.
2.2 Safety guidelines
CAUTION
•The device must not be used in a possible explosion area!
•The DMT must be operated by trained and authorised
personnel!
IMPORTANT
•The system must be suitably equipped and configured to
prevent overdosing of hazardous materials due to probe
failure.
•The DMT has no on/off switch. It starts to function as
soon as it is connected to a power supply.
3Storage and transport
Store and transport the DMT in the original packaging!
IMPORTANT
•Protect the DMT from damp and the effects of chemicals
even when packed!
Safety / Storage and transport

Page 8 ProMinent®
Ambient conditions for storage and transport:
Temperature: -20 °C to 70 °C
Humidity: max. 95 % relative humidity,
non condensing
4Assembly and installation
IMPORTANT
•The DMT is fully resistant to normal environments control
rooms.
•The DMT must be protected against rain and direct
sunlight!
Use a protective housing or weatherproof cover if in use
out of doors!
4.1 Assembly (mechanical)
The DMT can be wall, pipe or panel mounted.
4.1.1 Wall mounting
Mounting materials (included in delivery):
1 x wall/pipe bracket
2 x 5x45 mm round headed screws
2 x 5.3 washers
2 x 8 mm diameter plugs, plastic
1 x rubber insert
1 x locking screw (PT)
Wall mounting, please follow the steps below:
왘Remove wall/pipe bracket from DMT:
Pull the two snap fasteners outwards and push upwards (fig. 1, ➀).
Swing the wall/pipe bracket away from the DMT and pull downwards
(fig. 1, ➁).
왘Mark two drill holes diagonally opposite one another using the mounting
bracket as a template.
왘Drill the holes: Ø 8 mm, depth = 50 mm.
왘Screw the wall/pipe bracket in place inserting the washers (fig. 2).
왘If the DMT is also to be secured with a screw, pierce the screw hole in the
back of the housing (housing must be open) and attach a rubber insert
(fig. 2, ➀) to the bracket.
왘Hang the DMT onto the top of the bracket (fig. 3, ➀) and push down
gently against the bracket (fig. 3, ➁); then push upwards until you hear a
click (fig. 3, ➂).
왘Tighten the locking screw to secure more firmly (housing is open).
Storage and transport / Assembly and installation

Page 9
ProMinent®
2
3515_4
1
3
2
1
3464_4
Assembly and installation
Fig. 1 Fig. 2
Fig. 3
1
3461_4
4.1.2 Pipe mounting
Mounting material (included in delivery):
1 x wall/pipe bracket
2 x cable ties
1 x sealing cap
1 x locking screw (PT)
Can be mounted onto pipes of diameters from 25 mm to 60 mm.

ProMinent®
Page 10
Pipe mounting, please follow the steps below:
왘Remove wall/pipe bracket from DMT:
Pull the two snap fasteners outwards and push upwards (fig. 1, ➀).
Swing the wall/pipe bracket away from the DMT and pull downwards
(fig. 1, ➁).
왘Fasten the bracket to the pipe using the cable ties (or pipe clamps)
(fig. 3).
왘If the DMT is also to be secured with a screw, pierce the screw hole in the
back of the housing (housing must be open) and attach a rubber insert
(fig. 2, ➀) to the bracket.
왘Hang the DMT onto the top of the bracket (fig. 3, ➀) and push down
gently against the bracket (fig. 3, ➁); then push upwards until you hear a
click (fig. 3, ➂).
왘Tighten the locking screw to secure more firmly (housing is open).
4.1.3 Panel mounting
IMPORTANT
•The control panel must be thick enough not to buckle
once installed. (To achieve enclosure rating IP 54, steel
must be at least 2 mm thick; plastic should be
correspondingly thicker.)
NOTE
The DMT will protrude from the control panel approx. 30 mm
once mounted.
Fig. 4
3463_4
Assembly and installation
Tabla de contenidos
Manuales populares de Transductor de otras marcas

Mianyang Weibo Electronic
Mianyang Weibo Electronic WB Series Manual de usuario

MKS
MKS MicroPirani 925 Series Cómo utilizar

WIKA
WIKA WU-20 Manual de usuario

Alcatel Vacuum Technology
Alcatel Vacuum Technology BARATRON 622A Manual de usuario

Camille Bauer
Camille Bauer SIRAX CH-5610 Manual de usuario

WIKA
WIKA F2802 Manual de usuario