EN
10
2. Labels and Symbols
The labels on the inverter and on wiring box have the Agency marking, main technical data and identification of the equipment and
manufacturer.
NOTE –DThe labels shown below have to be intended as example only.
FORBIDDEN –HThe labels affixed to the equipment must NOT be removed, damaged, stained, hidden, etc., for any reason
whatsoever.
Power module
A
A
E
PVS-100_120-TL_B2_S(X-Y)2
6A
6B
6C
6D
5A
5B
5C
5D
3A
3B
3C
3D
4A
4B
4C
4D
2A
2B
2C
2D
1A
1B
1C
1D
Wiring Box
MODEL NAME
POWER-ONE ITALY S.p.A
Via S.Giorgio 642, Terranuova Bracciolini (AR), 52028, Italia
P/N:PPPPPPPPPPP
WO:XXXXXXX
SO:SXXXXXXXX Q1
SN:YYWWSSSSSS WK:WWYY
A
B
C
D
A. Inverter/wiring box model
B. Inverter/wiring box Part Number
C. Inverter/wiring box Serial Number
D. Week/Year of manufacture
E. Main technical data
NOTE –DAn additional PN and SN label of the full system (power module +
wiring box) is applied on the external packaging. This label should be stored in
plant documentation for reference.
WARNING!
NRS 097-2-1:2017 (South Africa)
It is not intended to connect this Inverter to a network with an higher
Network Impedance.
Reference Impedance
Fault Level
0.156
1475
Total [Ω]
I_SC [ A ]
3.9
1018
X/R ratio
S_SC [kVA] (three phase)
ATTENTION –AFor connection to the network in South Africa. According to
NRS097-2-1 requirements, at the end of installation it is mandatory to apply the
label at the left (supplied with the inverter) near the power module regulatory
label.
Communication Identification label:
The Communication Identification label (applied on the wiring box) is divided in two separate parts by a dashed line; take the bottom part
and apply it on the plant documentation. (FIMER recommend to create a plant map and apply the Communication Identification label on it).
SN WLAN: SSSSSSSSSS
PN WLAN: .V2PVKA 53.1
Mac Address:
AA:BB:CC:DD:EE:FF
PK: 0000 - 0000 - 0000- 0000
SN WLAN: SSSSSSSSSS
SN Wiring Box: ZZZZZZZZZZ
Remove and apply on the plant documentation
MAC: AA:BB:CC:DD:EE:FF
F
G
H
J
I
F. WLAN embedded board Serial Number
G. WLAN embedded board Part Number
H. MAC address:
- To be used to obtain the SSID of the wireless access point created by the
inverter: ABB-XX-XX-XX-XX-XX-XX (where “X” is a hex digit of the MAC
address).
- To be used to obtain the “Host Name”: http://ABB-XX-XX-XX-XX-XX-XX.local
(where “X” is a hex digit of the MAC address).
I. Product Key:
To be used as wireless access point password, or to be used to access to
the Web UI as username and password in case of lost credentials, and to
commission inverter using FIMER Installer for Solar Inverters.
J. QR Code:
To be used to commission inverter using FIMER Installer for Solar Inverters for
claiming process.