Detex DSI DS100-R Manual de usuario

DS100-R Waist High Turnstile
Service & Installation Manual
Note: Successful turnstile installation depends on reading this manual.
Please keep this service manual after installation. If an installation is done by a construction company
or outside installer, please pass this book along to the end user. This book is required for maintenance,
troubleshooting & repairs.
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

Important Electrical Information
Installation of the control head mechanism into the turnstile requires a grounding-type outlet recep-
tacle installed inside of the frame or cabinet through the provided conduit access points.
To reduce the risk of electric shock, this equipment has a grounding type plug that has a third
Additionally, the P24-60W power supply from this appliance must be grounded to the frame of the
turnstile. Utilize the green colored grounding screw threaded into the grounding tab located near the
power supply along with the provided grounding wire from the power supply to ensure the equip-
ment is properly grounded.
Do not connect to a receptacle controlled by a switch.
Feature Level
Destructive Attack Test I
Line Security I
Endurance IV
Standby Power I
ULC S319, Class 1
Wiring methods shall be in accordance with:
National Electrical Code, ANSI/NFPA 70
Canadian Electrical Code, CSA C22.1, Part I, Safety Standard for Electrical Installations
When in an appropriate turnstile or gate model, the 6500 Series Control Head is suitable for indoor and
outdoor use.
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

Table of Contents
Important Electrical Information 2
Model Datasheet 4
Preinstallation Tips 6
Installation Instructions 7
Concrete Anchor Information 8
Mechanical Overview 9
Internal Parts Breakdown 10
Parts List 11
12
Locking Bar Information 13
Hydraulic Shock & Indexing 15
Electrical Introduction 16
Wiring Diagram 17
Wiring Legend 18
Logic Controller Settings 19
Testing Procedure 20
Limit Switch & Limit Switch Cam Information 21
Maintenance & Cleaning 22
Troubleshooting 23
Proper Turnstile Usage 26
Warranty 27
Appendix
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

The DS100-R Series is our premier
interior application unit. It is ideal for
embassies, and museums. This highly
versatile line can take on any look. It
features our signature 304 stainless steel/
match your design needs.
Built in the USA
DS100-R
The DS100-R Series Waist-High DS100-R
Round End |Interior Application
Autumn
Flurries
Pewter
Blue Jeans
Lake Michigan
Spanish Moss
Concrete
Obsidian
Honey Oat
Crushed Almond
Peach Freeze
Whole Wheat
Standard top selections include:
* Subject to availability
Optional wood top
upgrade shown
with lights
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

Applications:
This interior application unit is designed for
embassies and museums.
Product Features:
Materials and Finishes:
• Lid:
choice of 12 standard colors selections.
Custom colors and Corian™ can be quoted
• Cabinet: Our signature 304 stainless steel/
Design & Construction:
• Designed for secure and reliable operation
• Cabinet constructed of 304 stainless steel/
•
•
Dimensions:
• Height:
• Width:
• Depth:
• Arm Length:
Operation Features
6500 Series Control Head:
•
hydraulic shock suppression
• Hardened tool steel locking bars, cam and
roller assemblies
• Permanently lubricated bearings
• Your choice of manual or electronic control on
both directions
• Nearly universal integration to any number of
access control syst ems
• Your choice on each electronic direction of
Options:
• Bi-directional key overrides
•
year lithium battery
•
•
choices outside of our standard selection
• NEW!
available
• Additional options available upon request
* Dimensions are approximate
The DS100-R Series Waist-High DS100-R
Round End |Interior Application
Warranty:
defects in materials and
one year from date of delivery.
Input Voltage: 100-240 VAC
Input Current: 1.3 - .55 A
Frequency: 50/60 Hz
Storage Temperature: -40 to 158°F
Operating Temperature: -4 to 131°F
Operating Voltage: 24VDC
Standards and Codes:
Austenitic stainless steel:
ASTM A240, A249, A276
Hot rolled steel:
AISI C-1020, AISI C-1018
All fasteners provided meet IFI ANSI/
ASME Fastener Standards
Standard D 1.1
The 6500 Series Control Head
UL 294, UL 325, UL Subject 2593,
CAN/ULC S319 & CSA C22.2#247
4008027
Our matching ADA gate
(DS100-R-ADA with optional
motorization) is available for
DS100-R Series.
* Dimensions are subject to change without notice
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555
Electrical Specications:

Pre-installation Tips
To ensure an easy installation, please review the following tips before trying to install the unit.
Lid Removal
The top lid on most of our waist high models is held in place on the front side with a lock and
two hooks that connect to the cabinet on the rear. After the lock has been released, the rear
hooks can be unlatched by pulling the lid from the back side forward then pivoting upwards
in one motion.
Front Panel Removal
panel needs to be removed. This is accomplished by removing the two 10/32 phillips screws
that connect the front panel to the cabinet located at the upper inside of the cabinet.
Step 1: Unlock Lid Step 2: Pull lid forward Step 3: Pivot up in back while pulling forward.
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

Waist High Cabinet Installation Instructions
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555
Place upright cabinet with front panel removed onto a level surface +/- 1/16”. If the surface is
may cause it to work improperly.
drill four 3/8” holes approximately 4”deep. Remove all concrete dust from the holes.
Place the cabinet back in its intended location and install with the provided 3/8”concrete
anchors. Torque the nuts with a minimum of 25 foot pounds. If unsure, refer to the following
page for anchor installation tips.
If electronically controlled, install grounded electrical outlet within the cabinet and ground
the power supply to the cabinet frame with provided grounding wire.
diagram provided later in this manual.
Install arm assembly (if applicable) to the arm adapter utilizing the three 5/16-18”socket head
cap screws. We recommend applying removable strength (blue) thread sealant such as
Loctite 243 to these screws.
Test the turnstile or ADA gate for proper functionality, making adjustments to the hydraulic
shock absorber as needed (reference hydraulic shock information later in this manual).
Reinstall the front panel and lid on the cabinet then provide this manual to the end user or
leave within the cabinet for future reference.
Mark or punch the oor using the four anchor holes on the oor plate as a template and

Use in concrete ONLY. Not recommended for use in lightweight masonry such as block or brick.
Warning!
Always wear safety glasses and other necessary protective devices or apparel when installing or working with anchors.
Caution: Use of core drills is not recommended to drill holes for use with this anchor.
The use of carbide drill bits manufactured with ANSI B212.15 drill bit diameter requirements is recommended for installation of this anchor.
Anchor spacing and edge distance (anchor installation locations) are the responsibility of the engineer of record.
Installing product in oversized holes is not recommended. Product will not set properly or achieve full designed load in oversized holes.
* Setting torque only applies at the time of installation.
4
Select a carbide drill bit with a diameter equal to the anchor diameter. Drill hole at least 1/4” deeper than nominal anchor embedment.
Clean hole with pressurized air or vacuum to remove any excess dust/debris.
Using the washer and nut provided, assemble the anchor, leaving nut one half turn from the end of anchor to protect threads. Drive
Wedge Type Concrete Anchor Instructions
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

6500 Series Control Head Mechanical Information
All of our turnstiles and ADA gates operate with a mechanism called the 6500 Series Control Head.
This sturdy and easy to maintain drive for the turnstile has replaced all previous model control heads.
It is adaptable to nearly any existing turnstile and comes with each new turnstile purchase. This control
job site.
An internal view of an electronically controlled two way 6500 series control head.
potential is reached in the case of an electronic two way control head. In this instance, each rotational
per valid entry request. Our anti-backup cams are designed so that it is mechanically impossible to
become trapped within the turnstile when properly installed.
recommendations. Installation is simple: connect inputs from access control devices into the logic
controller and plug the unit’s power supply into a 100-240 VAC (single phase) receptacle. The power
supply will automatically set itself to function on your local voltage and convert it to 24VDC.
512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555

512-321-4426
INS-DS100R-190401
Designed Security, Inc. - 1402 Hawthorne Street, Bastrop Texas 78602 - (800) 272-3555
Tabla de contenidos
Otros manuales de Torniquete de Detex