Deif CIO 308 Manual de usuario

INSTALLATION AND COMMISSIONING GUIDE
CAN bus-based I/O module, CIO 308
8 multi-inputs
• Mounting
• Terminals and wiring
• Commissioning, using the utility software
DEIF A/S · Frisenborgvej 33 · DK-7800 Skive
Tel.: +45 9614 9614 · Fax: +45 9614 9615
[email protected] · www.deif.com
Document no.: 4189341078D
SW version: 1.10.0

1. Introduction
1.1 Warnings, legal information and safety.........................................................................................................................................................................3
1.1.1 Warnings and notes.......................................................................................................................................................................................................... 3
1.1.2 Legal information and disclaimer.................................................................................................................................................................................3
1.1.3 Safety issues........................................................................................................................................................................................................................3
1.2 About the installation and commissioning guide.................................................................................................................................................... 4
1.2.1 General purpose.................................................................................................................................................................................................................4
1.2.2 Intended users.....................................................................................................................................................................................................................4
1.2.3 Contents and overall structure......................................................................................................................................................................................4
2. Installation, mounting and wiring
2.1 Installation..................................................................................................................................................................................................................................... 5
2.2 Mounting.........................................................................................................................................................................................................................................5
2.2.1 Mounting the CIO modules............................................................................................................................................................................................ 5
2.2.2 Dimensions........................................................................................................................................................................................................................... 5
2.3 Common functions....................................................................................................................................................................................................................6
2.4 Wiring and terminals................................................................................................................................................................................................................8
2.4.1 Terminal overview CIO 308............................................................................................................................................................................................8
2.4.2 CIO 308 wiring.................................................................................................................................................................................................................. 11
2.4.3 CAN bus...............................................................................................................................................................................................................................11
3. Communication
3.1 Communication setup...........................................................................................................................................................................................................14
3.1.1 Step-by-step guide to setting up communication the first time.....................................................................................................................15
3.1.2 Step-by-step guide to update firmware to CIO module................................................................................................................................... 15
4. I/O setup
4.1 CIO info tab.................................................................................................................................................................................................................................16
4.2 Status relay.................................................................................................................................................................................................................................16
4.3 Multi-input....................................................................................................................................................................................................................................18
4.3.1 Setting up a multi-input................................................................................................................................................................................................. 18
4.3.2 Thermocoupler with cold junction compensation............................................................................................................................................... 20
4.3.3 Wire fail detection............................................................................................................................................................................................................21
4.3.4 Change text in the display............................................................................................................................................................................................23
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 2 of 24

1. Introduction
1.1 Warnings, legal information and safety
1.1.1 Warnings and notes
Throughout this document, a number of warnings and notes with helpful user information will be presented. To ensure that these are
noticed, they will be highlighted as follows in order to separate them from the general text.
Warnings
DANGER!
This highlights dangerous situations. If the guidelines are not followed, these situations could result in death, serious
personal injury, and equipment damage or destruction.
CAUTION
This highlights potentially dangerous situations. If the guidelines are not followed, these situations could result in personal
injury or damaged equipment.
Notes
INFO
Notes provide general information, which will be helpful for the reader to bear in mind.
1.1.2 Legal information and disclaimer
DEIF takes no responsibility for installation or operation of the generator set. If there is any doubt about how to install or operate the
engine/generator etc. controlled by the specific extension, the company responsible for the installation or the operation of the
extension must be contacted.
DANGER!
The CIO module is not to be opened by unauthorised personnel. If opened anyway, the warranty will be lost.
Disclaimer
DEIF A/S reserves the right to change any of the contents of this document without prior notice.
The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not
take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document.
If there is a discrepancy, the English version prevails.
1.1.3 Safety issues
Installing and operating the CIO module may imply work with dangerous currents and voltages. Therefore, the installation should
only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment.
DANGER!
Be aware of the hazardous live currents and voltages. Do not touch any live inputs as this could lead to injury or death.
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 3 of 24

1.2 About the installation and commissioning guide
1.2.1 General purpose
This installation and commissioning guide mainly includes general product and hardware information, mounting instructions, terminal
strip descriptions, I/O lists and limits, wiring descriptions and how to produce translations for the CIO module through the USW.
The general purpose of this document is to give the user important information to be used in the installation of the unit.
DANGER!
Please make sure to read this document before starting to work with the CIO module and the controller. Failure to do this
could result in human injury or damage to the equipment.
1.2.2 Intended users
This installation and commissioning guide is mainly intended for the person responsible for the design and installation. In most
cases, this would be a panel builder designer. Naturally, other users might also find useful information in the document.
1.2.3 Contents and overall structure
This document is divided into chapters, and in order to make the structure simple and easy to use, each chapter will begin from the
top of a new page.
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 4 of 24

2. Installation, mounting and wiring
2.1 Installation
Installation
The CIO module is delivered in a sturdy carton to prevent shipping damage. When you receive a system, check the part number
against that of the requisition and packaging list for agreement. Inspect for damage, and if there is evidence of such, immediately file
a claim with the carrier and notify the regional DEIF sales office, your sales representative or a sales representative at DEIF's head
office in Skive, Denmark.
If the unit is not installed immediately, store it in the original shipping package in a moisture and dust free environment.
2.2 Mounting
2.2.1 Mounting the CIO modules
The CIO module is designed for mounting in a closed cabinet on a DIN rail. The module can be mounted on either a TS35 or G-type
rail. The unit must be mounted where the ambient temperature does not exceed the range -40 to +70 ⁰C.
2.2.2 Dimensions
The CIO 308 module dimensions are presented here in mm (inches):
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 5 of 24

2.3 Common functions
1. LED1 (Status LED)
LED1 indicates the operation status of the module, and the status output of this LED is located at terminal 3-4.
Set up as either status or configurable relay:
Set up as status relay
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 6 of 24

LED colour Description
Green Status is OK, the relay is closed.
Red constant The CIO module is not working correctly, the relay is open.
Red flashing ID 0 is selected, relay is open.
Set up as configurable relay
LED colour Description
Green Status is OK, the relay is closed.
Turned off/no light Status is OK, the relay is open.
Red constant The CIO module is not working correctly, the relay is open.
Red flashing ID 0 is selected, relay is open.
Yellow The relay is closed, status is not OK.
2. Terminal resistor
The CIO module has a built-in 120 ohm end-termination for the CAN bus line which can be activated via the switch (S1) located at
terminal 5. See the section "CAN bus" in "Wiring and terminals" for more information and to see when to activate the switch.
3. LED2 (CAN bus LED)
LED2 indicates the status of the CAN bus communication to the host controller. This LED is located at terminal 7.
LED colour Description
Green constant Communication to the controller is working correctly.
Red constant No CAN bus communication detected.
Red 2 flashes CAN bus communication detected, but no CIO-specific
communication
Red flashing CIO communication detected, but not to this module.
4. ID selector
The ID selector is used to give CIO modules of the same type different IDs.
CIO 116 can use IDs from 1 to 15
CIO 208 can use IDs from 1 to 15
CIO 308 can use IDs from 1 to 15
5. USB for firmware update
The firmware of the CIO modules can be updated via the USB port.
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 7 of 24

2.4 Wiring and terminals
2.4.1 Terminal overview CIO 308
Terminal Name Description Comment
1 + +12/24 V DC
Power supply
2 - 0 V DC
3
Status
Common
Status output (configurable)
4 Normally open
5 H CAN-High
CAN bus interface 6 Com CAN-Common
7 L CAN-Low
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 8 of 24

Terminal Name Description Comment
8
I8
Input A
Multi-input 8
Multi-input group 1
9 Input B
10 Input C
11
I11
Input A
Multi-input 11 12 Input B
13 Input C
14
I14
Input A
Multi-input 14
15 Input B
16 Input C
17
I17
Input A
Multi-input 17 18 Input B
19 Input C
20
I20
Input A
Multi-input 20
Multi-input group 2
21 Input B
22 Input C
23
I23
Input A
Multi-input 23 24 Input B
25 Input C
26
I26
Input A
Multi-input 26 27 Input B
28 Input C
29
I29
Input A
Multi-input 29
30 Input B
31 Input C
Input LED
Each multi-input has its own LED, and the table below illustrates when the LED is on/off.
Input type LED Description
Digital input
On Input is active
Off Input is inactive
0(4) to 20 mA
On Within input range 4 to 20 mA
Off
Outside input range 4 to 20 mA (LED is
flashing when in protection mode: >30
mA)
0 to 10 V
On Within input range 0.2 to 10 V
Off Outside input range 0.2 to 10 V
RMI
On Within input range 10 to 2500 Ω
Off Outside input range 10 to 2500 Ω
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 9 of 24

Input type LED Description
Pt100 sensor
On
Within selected input range (Low range
-50 to 250°C or high range: -200 to
850°C)
Off
Outside selected input range (Low range
-50 to 250°C or high range: -200 to
850°C)
Pt1000 sensor
On
Within selected input range (Low range
-50 to 250°C or high range: -200 to
850°C)
Off
Outside selected input range (Low range
-50 to 250°C or high range: -200 to
850°C)
Thermocouple
On Within input range of selected type of
thermocouple
Off Outside input range of selected type of
thermocouple
INSTALLATION AND COMMISSIONING GUIDE 4189341078D EN Page 10 of 24
Otros manuales para CIO 308
1
Tabla de contenidos
Otros manuales de Unidad de control de Deif

Deif
Deif Delomatic 4 AOP-2 Guía

Deif
Deif Multi-line 2 Manual de usuario

Deif
Deif GPC-3 Hydro Manual de usuario

Deif
Deif PPU 300 Manual de usuario

Deif
Deif PCM 4 Series Guía

Deif
Deif GCU 100 Manual de usuario

Deif
Deif Multi-line 2 Manual de instrucciones

Deif
Deif DELOMATIC 4 Series Suplemento

Deif
Deif GCU 100 Manual de usuario
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards