D-Link DMC-1002 Manual de usuario

DMC-1002
Management Module for DMC-1000 Shassis
Модуль упр вления для ш сси DMC-1000
Quick Installation Guide
Краткое руко одст о по устано ке
RECYCLABLE
1

PACKAGE CONTENTS
Thank you and congratulations on the purchase of your new D-Link
DMC-1002 Management Module. The product you have purchased
should contain the following items:
DMC-1002 Management Module
Console cable
CD-ROM
User manual
Warranty certificate
If any of the above items are damaged or missing, please contact your
local reseller for replacement.
INTRODUCTION
The DMC-1002 Management Module is a plug-and-play replacement
module for the original DMC-1000 CPU slot. The DMC-1002 provides
network administrators with a set of comprehensive management
features to configure and monitor smart media converters installed in
the DMC-1000 chassis, centralizing management of up to 16 smart
media converters from a single web-based or command line user
interface.
2

HARDWARE OVERVIEW
Front Panel View
Figure 1
# Item Description
1 RJ45 Console Port Used for connecting to a remote workstation running
terminal emulation software for accessing the
command line interface.
2 10/100/1000BASE-T
Port
Used for connecting the DMC-1002 to the network
and to access the web-based UI.
Table 1
3

LED Indicators
Figure 2
# LED Status Description
1 Power On 1, 2 Green Power supply is connected and operational.
2 Power Fail 1, 2 Amber Power supply is connected but is not
powering devices.
3 Fan Fail 1, 2 Amber Indicates a problem with one or both chassis
fans.
4 MGM Blinking green The DMC-1002 (CPU) is operational.
Amber The DMC-1002 (CPU) is experiencing
problems.
5 Console Blinking green Data is being sent through the console port.
Blinking amber An active Ethernet link has been established.
6 Link/Act Blinking green Data is being sent and received on this
connection.
Table 2
4

HARDWARE INSTALLATION
This chapter provides step-by-step instructions on how to install the
DMC-1002 into the DMC-1000 chassis.
Step 1: Install the management module by replacing the original
DMC-1000 module in the first slot of the chassis with the DMC-1002,
as shown in Figure 3. Note that the first slot (CPU slot) of the
DMC-1000 is always reserved for mounting the DMC-1002 module.
Due to its unique slot connector design, the DMC-1002 cannot be
placed in any other slot in the chassis.
Figure 3
Step 2: Connect the module to the network by attaching one end of a
compatible network cable to the 10/100/1000BASE-T port on the
module and the other end to the network device (e.g. router, switch).
Step 3a: Access the web-based management User Interface (UI) by
opening a supported web browser and type in the device's default IP
address into the browser's address bar. The default IP address can
later be changed through the web UI or command line interface (CLI).
If the default IP was previously changed, log into the module using the
updated IP address instead.
Step 3b: To use the Command Line Interface (CLI) on a terminal
simulation program, connect the RJ45 connector of the included RJ45
to DB9 console cable to the RJ45 port marked "Console" on the
module and attach the serial DB9 connector to the management PC.
Alternatively, the CLI interface can be accessed by using the module's
IP to connect through Telnet.
5

CONFIGURATION THROUGH
THE WEB- BASED UI
The management interface can be accessed through a web browser
such as Internet Explorer, Chrome, or Firefox by typing the
DMC-1002's default IP address of 192.168.1.1 into the browser's
address bar. When prompted to log in, enter the default login
username "root" and password "root" (without quotes).
6

TECHNICAL SPECIFICATIONS
Interface
Number of Ports • 1 x 10/100/1000BASE-T port • 1 x RJ45 Console port
Management and Functionality
Chassis • Part Number
• Description
• Power Status
• Revision
• Chassis Reset
Media Converter
Modules
• Link Status
• Slot Occupied
• Revision
• Converter Type
• Part Number
Alarms • Cold Start
• Link Up
• Authentication Failure
• Power Supply Inserted
• Module Insertion
• Module Unknown
• Revision
• Warm Start
• Link Down
• Power Supply On/Off
• Power Supply Removed
• Module Removal
• Module Failure
Active Control • Link Loss Carry Forward
• Module Name
• Reset Module
• Download Software via TFTP/HTTP
• Default Gateway
• Link Loss Return
• IP Address
• Redundant Backup
• Subnet Mask
• Telnet to Console Commands
Supported Protocols • IP
• SNMP
• TFTP
• ICMP
• UDP
• TCP
• ARP
• HTTP
Physical
Diagnostic LEDs • Power 1, 2
• Power Fail 1, 2
• Fan Fail 1, 2
• MGM
• Link/Activity
• Console
Weight • 0.12 kg (0.26 lbs)
Temperature • Operating: 0 to 40 °C (32 to 104 °F) • Storage: -20 to 70 °C (-13 to 158 °F)
Humidity • Operating: 10% to 90%
non-condensing
• Storage: 5% to 90% non-condensing
Dimensions
(L x W x H)
• 130 x 88 x 35 mm (5.12 x 46 x 1.38
in)
Certifications • FCC Class A
• CE Class A
• VCCI Class A
7

ПРАВИЛА И УСЛОВИ БЕЗОПАСНОЙ
ЭКСПЛУАТАЦИИ
Вним тельно прочит йте д нный р здел перед уст новкой и подключением
устройств . Убедитесь, что устройство не имеет мех нических повреждений.
Устройство должно быть использов но только по н зн чению, в соответствии
с кр тким руководством по уст новке.
Устройство предн зн чено для эксплу т ции в сухом, чистом, нез пыленном
и хорошо проветрив емом помещении с норм льной вл жностью, в стороне
от мощных источников тепл . Не используйте его н улице и в мест х с
повышенной вл жностью. Не р змещ йте н устройстве посторонние
предметы. Вентиляционные отверстия устройств должны быть открыты.
Темпер тур окруж ющей среды в непосредственной близости от устройств
и внутри его корпус должн быть в предел х от 0 до +40 °C.
Электропит ние должно соответствов ть п р метр м, ук з нным в
технических х р ктеристик х устройств .
Не вскрыв йте корпус устройств ! Перед очисткой устройств от
з грязнений и пыли отключите пит ние устройств . Уд ляйте пыль с
помощью вл жной с лфетки. Не используйте жидкие/ эрозольные
очистители или м гнитные/ст тические устройств для очистки. Избег йте
поп д ния вл ги в устройство и д птер пит ния.
Срок службы устройств - 2 год .
Г р нтийный период исчисляется с момент приобретения устройств у
офици льного дилер н территории России и стр н СНГ и сост вляет один
год.
Вне з висимости от д ты прод жи г р нтийный срок не может превыш ть
2 год с д ты производств изделия, котор я определяется по 6 (год) и
7 (месяц) цифр м серийного номер , ук з нного н н клейке с техническими
д нными.
Год: C - 2012, D - 2013, E - 2014, F - 2015, G - 2016, H - 2017, I - 2018, J - 2019,
0 - 2020, 1 - 2021.
Месяц: 1 - янв рь, 2 - февр ль, ..., 9 - сентябрь, A – октябрь, B - ноябрь,
C - дек брь.
8
При обнаружении неисправности устройства обратитесь в сервисный центр
или группу технической поддержки D-Link.

ВВЕДЕНИЕ
Модуль упр вления DMC-1002 предст вляет собой сменный блок
упр вления для ш сси DMC-1000. Д нный модуль поддержив ет
технологию Plug-and-play.
Модуль упр вления DMC-1002 позволяет отслежив ть р боту до
16 меди конвертеров, уст новленных в ш сси DMC-1000.
Упр вление осуществляется центр лизов нно через
Web-интерфейс или посредством CLI.
КОМПЛЕКТ ПОСТАВКИ
Проверьте по списку н личие всех компонентов и убедитесь, что
они не повреждены. Если что-либо отсутствует или есть
повреждения, обр титесь к В шему пост вщику.
Модуль упр вления
Консольный к бель RJ45 to DB9
CD-диск
Эксплу т ционн я документ ция
Г р нтийный т лон
9

ОБЗОР
Передняя п нель
Рис.1
№ Порт Функция
1 Console Подключение н прямую к консольному порту и
упр вление модулем DMC-1002 с помощью CLI
2 10/100/1000BASE-T Подключение модуля DMC-1002 к сети и
упр вление им через Web-интерфейс
Таблица 1
10
Otros manuales para DMC-1002
2
Tabla de contenidos
Idiomas:
Otros manuales de Unidad de control de D-Link
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario