1.4 M&C Commands
The following tables summarize the commands and status queries applicable to the 1582-225L2 Switch.
*PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
Table 2.0 Model 1582-225L2 - M&C Remote Commands
Will (remotely) set Switch 2 to BACK-UP. The unit will ignore this command if the switch
is in manual mode. The unit will reply with the '>' character if the command is
successfully processed.
example: {CS2}
3. The switch position is manually selected via the front panel Manual Select toggle
switch. If the switch is already in manual mode (i.e, the front panel toggle switch is in the
PRIMARY or BACK-UP position) then the switch will ignore this command.
2. The front panel Switch Reset button is pressed.
1. A Switch Reset (SW2) command ( {CC} ) is issued.
2. The front panel Switch Reset button is pressed.
x = desired switch position; x=1 to select P; x=2 to select BU. Once the switch position is
selected remotely, the switch is in "Remote Mode" and the front panel remote indicator
will light. The switch will remain in Remote Mode until one of the following occurs.
S = Command Code
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
where:
{aaCSx}Set RF Switch Position (SW2)
Will (remotely) set the switch to BACK-UP. The unit will ignore this command if the
switch is in manual mode. The unit will reply with the '>' character if the command is
successfully processed.
1. A Switch Reset (SW1) command ( {CB} ) is issued.
example: {CR2}
3. The switch position is manually selected via the front panel Manual Select
toggle switch.
x = desired switch position; x=1 to select P; x=2 to select BU. Once the switch position is
selected remotely, the switch is in "Remote Mode" and the front panel remote indicator
will light. The switch will remain in Remote Mode until one of the following occurs.
R = Command Code
If the switch is already in manual mode (i.e, the front panel toggle switch is in the
PRIMARY or BACK-UP position) then the unit will ignore this command.
aa = unit address, range = 00 to 31, only used if interface is RS485, otherwise omit
where:
{aaCRx}Set RF Switch Position (SW1)
Command DescriptionSyntaxCommand Function
Table 2.0: Model 1582-225L2 1:1 Switch, M&C Remote Commands
Table 2.0 M&C Remote Commands Continued on page 10...
1582-225L2 Manual, Rev. A Page 9 04/26 /18