1.2 Technical Characteristics
2082-141-47 Manual, Rev. 0 Page 4 01/15/14
In
ut Closure Alarm O
tion: Call Cross Technolo
ies
Other O
tions
Ethernet with Direct TCP/IP InterfaceW28-
LNA/LNB Power
Switch Drive Characteristics
Alarm and Control
M&C
Controls
Indicators
Controls
Others
*+10˚C to +40˚C; Specifications subject to change without notice 2012 Cross Technologies, Inc.
1:1 Redundant Unit Controller
Ground Common2082-141-47P
1:1 Redundant Unit Controller
+47 VDC Common2082-141-47
Models
Ethernet with SNMP
and MIB
InterfaceW18-
Remote M&C Ethernet O
tions
Ethernet with Web Browser InterfaceW8-
Redundant 100-240 ±10% VAC, 47-63 Hz, 150 Watts max.
ower su
liesPower
1 RU, 19 inch standard chassis, 1.75” high x 16.0” deepSize
MS3112E16-23SAm
Plate Connector
DB9
femaleM&C Connector
DB9, femaleExternal Alarm
DB37, femaleParallel I/O Connector
Red LEDʼs, External Form C contact closure, M&C serial
(for amplifiers, Ext. and Summary alarm)
Alarm Status
Yellow LED, External Form C contact closure, M&C serialManual Select Status
Yellow LED, External Form C contact closure, M&C serialRemote Select Status
Green LEDʼs
PS1, PS2
, External Form C contact closure, M&C serial
Mode Select Local/Remote, Auto/Manual push-button switches, contact closures,
or remote selection.
Power On Status
47 Volts
1.5 Am
s
Drive Volta
e
TABLE 1.0 2082-471-47 Switch Specifications*
900 baud rate, no
arit
, 8 data bits, 1 start bitM&C Si
nal
RS232C or RS485, Selectable, Ethernet O
tionalM&C Interface
Form C rela
: 100 VDC, 0.5A, 3W max.Alarm Output Si
nal
100 ms max.
based on switch s
ecificationsTotal Switch over time 50 ms max.Fault Detection time
2, Primar
& Backu
Number Powered
+15 ±1 Volts/0.6 am
s max., each unitOut
ut Volta
e/Current