1. Introduction
The Easyush Direct valve provides electronic ushing of the WC without the need for a WC cistern. There
are two versions:
Easyush Wave is operated by the user bringing their hand towards the infrared sensor. A part ush is
triggered by holding the user’s hand in place for 1 second; a full ush is triggered by a hand pass of over 1
second. The dual ush setting is a factory default but can be changed by the installer.
Easyush Direct Walkaway is activated when the user stands up or leaves the cubicle but it can also be
activated by the user bringing their hand toward the sensor. The dual ush setting is a factory default but
can be changed by the installer. A part ush is triggered by short user occupancy and a full ush by long
user occupancy (over 45 seconds).
With Easyush Direct there is no cistern to be relled; this means a second ush can be activated without
a delay. The product includes a hygiene rinse function.
Supplied parts
1 Sensor unit
2 Valve unit
3 Sensor nut
4 Sensor rubber gasket
5 Clamp plate
6 DC pipe interrupter
inc. ow regulator
7 Valve rubber seal
8 Cap seal
9 Cap washer
10 Cap nut
11 Long screws
12 Short screws
13 Sticky pad
14 6mm screw packer
15 Extension cable
16 Mains adapter
1
5
3
2
4
11
12
6
8
7
915
13
14
16
10
Optional extras
1.5" brass ush pipe tting (DWC/4)
X
1
x
4
x
2

Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 3
2. Installation
IMPORTANT: Read this before tting the WC valve.
Flushing directly from the mains water supply
When ushing WCs or urinals directly from the mains, the Water Regulations require that the water supply
be protected by a suitable category 5 protection method or device.
In the case of WCs, this can be achieved in three ways:
1 The use of a dedicated supply for ushing use only, supplied from a break tank that protects the mains
supply with a type AA, AB or AD air gap.
2 The use of a specic type of WC bowl which has been tested and shown to incorporate the equivalent
of a type AB air gap.
3 The use of a type DC pipe interrupter (supplied with all Cistermiser Direct Flushing products).
A note about type DC pipe interrupters
These devices have an integral air gap; it is therefore important that pipework design and WC bowl
selection are appropriate to ensure sucient ow to ush the WC while preventing water owing back up
and out of the air gap.
The DC pipe interrupter must be installed not less than 150mm above the spill over level of the WC pan.
Ensure you follow these key design & installation points
• Install the valve as high as possible above the WC bowl.
• Install a free-owing, low restriction connection from the valve to the WC bowl. Ensure the water system
can deliver min. 90 lpm.
• Use a large pipe size in the pipework between the DC pipe interrupter and the WC.
• The DC pipe interrupter is tted with a 100 lpm ow regulator to control the ow of water; if you still have
issues with the DC pipe interrupter overowing, it may be necessary to install a further ow restricting
device upstream of the valve.
NOTE:
For grey water/rain harvesting. Ensure
adequate ltering is tted, a 10μm lter is
recommended. NOTE:
For chemical water treatment. If the water
system had been treated with chemical dosing,
ensure the system is thoroughly ushed before
tting any Cistermiser products. Concentrated
chemicals in dead legs can damage the
product and result in failure. If the water is
treated with Chlorine Dioxide (ClO2), ensure
concentration levels are maintained below
5ppm.Ensure adequate ltering is tted, a
10μm lter is recommended.
NOTE:
As with all water containing products, limescale
in hard water areas can aect the products
performance. This can result in maintenance
to remove the limescale when required.Ensure
adequate ltering is tted, a 10μm lter is
recommended.

4 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
3. Installation schematic
The valve must be installed at least
150mm above the spill over level to
comply with Water Regulations.
When installing the valve it is good
practice to ensure there is an
accessible isolating valve upstream of
the valve.
Ensure ow rate at valve
A
does
not exceed the ow rate to the WC
bowl
B
to prevent water backing-up
to the DC pipe interrupter.
A 1.5m extension cable is supplied if
required for placement of sensor.
NOTE:
Flush pipework prior to installation.
Do not install opposite a mirror. When
installed opposite a shiny surface, the
range may require adjustment. See
section 8 Advanced settings guide.
DC pipe
interrupter
Water supply
Not less than 150mm
B
A
X
Pipework diagram
suggestion only
X– Walkaway version only
If this distance is less than 12cm it is recommended
that the Hand Activation is disabled. Refer to
Section 9. (ICU required; not supplied.)
DMA55 power supply included
with Easyush Direct (Requires 1A
fused spur)
4
a
\
f
K
ik
p
\
\
s
s
w
’
1
—
T
>
O
y
—
t
1

Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 5
Panel mounted sensor
WC
300 – 400mm
700 – 900mm
WAVE only WALKAWAY only
NOTE:
Sensor should be located outside body
shape for WAVE only.
NOTE:
Sensor should be located inside
body shape for WALKAWAY only.
WC
500 – 700mm
(Lower position
may be required
for schools)
N
\
I
/
k
/
/
\
\
t
t
I
I
1
\
\ \
yy
\
k
L
L
>
I
'
V
\
\
t t
\
\
I
1
l
I
I
k
k
\
I
I
.
I
'
1
I
.
I
.
I
I
1
1
)
I
\
\
I I
I
I
\
l
1
N N
\
\
k
/
/
/
I
k k
,
U
-
\ \
i
'
.
\
\
\
k
k
'
\
k
\
\
k k
I
I
t
I
I
I
I
(
(
s
V
s
\\
\
kk
\
s
t
l

6 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
Sensor gasket
Ø38mm
Apply
sanitary
silicone
sealant
Sensor nut
3 – 15mm
Ø44mm
Apply
sanitary
silicone
sealant
Sensor
gasket
Sensor nut
15 – 30mm
Apply
sanitary
silicone
sealant
M4
screw
Clamp plate
(reversible)
6mm packer
(See note*)
30 – 38mm
NOTE:
*If wall thickness is under 32mm use packer to prevent screw causing damage to sensor
Thin wall Medium thickness wall Thick wall
h
+
*
>
1
IDOUT
)
<
M
3
f
i
.
^
Wr
p
MQSIU
mm
Si
r
at
-
5
=
>
,
5
L
>
58
>
C
—
o
eggs

Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 7
NOTE:
Removing the DC pipe interrupter may
contravene the Water Regulations (see page 3).
NOTE:
If you wish to connect to a 2" ush pipe, an
adapter can be purchased from your local
plumbing merchant.
Easyush Direct is supplied with a DC pipe interrupter. Fit the DC pipe interrupter to the valve outlet
ensuring the rubber seal is in place.
Rubber seal
1” BSP
connesction
Easyush
Direct valve
Rubber seal
DC pipe
interrupter
Flush pipe
ttings
NOTE:
To connect to supply pipework you will require
a 1" female BSP to 22mm or 28mm (copper)
connection (not supplied).
If the DC pipe interrupter is not required
(see ‘Flushing directly from the mains water
supply’ in Section 2), t a 1.5
"
ush pipe tting
to the pipe outlet in place of the DC pipe
interrupter. Available as a spare part from
Cistermiser - DWC/4

8 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
4. Power Connections
Fasten the mains adapter into place on the panel in a dry location using the screws or adhesive pads
provided and connect the un-terminated mains cable to a 50Hz 230V AC single phase supply via a 1A
fused spur (not supplied).
Connect the spade connectors from the sensor to the solenoid terminals; take care to connect the wires
according to the colour coding on the label. If the wires are not long enough they can be extended by up
to 1.5 metres with the cable supplied.
NOTE:
Remove the label from the sensor BEFORE
connecting to the power. When the power is rst
connected the LED in the sensor ashes amber.
This is normal and lasts only a few seconds.
Power connector
DMA55 power supply included with Easyush
Direct (Requires 1A fused spur)
Additional conguration options
With the Infrared conguration unit (ICU) remote control (sold separately).
• Hygiene rinse on/o. The installer is able to switch the 12 hr hygiene rinse function on or o.
• Clean mode. The Easyush Direct can be disabled for a short period to allow for cleaning.
• Siphonic trap rell mode. When activated this allows a small ush after every ush to rell the siphonic trap.
• Toggle wave feature on/o.
Electrical connection
Connect the power connector from
the sensor to the
mains adapter.
Alternative power options
For multiple connections the Cistermiser
power supply unit (PSUC) can be
used to power up to 20 units
(not supplied).
NOTE:
When using a Cistermiser power supply unit
(PSUC), ensure that when connecting correct
polarity is ensured.
Brown wire = positive Grey wire = negative

Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 9
5. Configuration
IMPORTANT: Water Flow Rate Requirement
To achieve an eective and ecient ush, the water system needs to deliver at least 90 lpm. Typically this
would require that the dynamic/working water pressure, measured before the valve, is at least 2 bar.
To comply with the water regulations the full ush volume must not exceed 6 litres.
The Easyush Direct is tted with a 100 lpm ow regulator* that will limit the ow through the valve to
100 lpm.
The ush duration is set by default to 3.5 seconds, this ensures the ush volume will be below 6 litres.
The part ush will automatically be set to 0.6 x the full ush duration. This will ensure the part ush
volume is less than 2/3rd the full ush volume as specied in the Water Regulations.
To adjust the ush duration and therefore the ush volume see Section 8 ‘Advanced settings guide’
The ow rate can also be reduced by turning the adjuster screw in the middle of the valve (clockwise to
reduce ow) or by tting a third party pressure reducing valve above the Easyush Direct.
Ensure that the dynamic water pressure (pressure measured while the valve is open and water is owing)
is sucient to achieve the required ow rate.
*Alternative ow regulators are available. Please contact Cistermiser.
WARNING:
The use of several other appliances from the
same water supply simultaneously may reduce
the ow rate below 90 lpm.
NOTE:
On smaller pipe sizes please pay particular
attention that you achieve 90 lpm at the valve
outlet for an eective ush.

10 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611
6. Usage advice and specification
Minimum working pressure: An eective and ecient ush is achieved with a ow rate of >90
lpm. A typical installation will require 2bar dynamic pressure,
measured before the Easyush Direct, to achieve 90 lpm.
Maximum working pressure: 5 bar
Back siphonage protection: Class 5, Type DC
Factory settings
Range: EFD Wave – circa 18cm
EFD Walkaway – circa 65cm (9cm for hand activation)
Full ush duration: 3.5 seconds
Part ush duration: 2 seconds
Power requirements: 6V DC regulated from mains adapter (1A fused spur required)
Cleaning: Clean with soap and water only
Lens care: Infrared lens can be polished with a soft cloth
Electronic specication
Control classication: Independent
Maximum load: 2W, 0.33A (6VDC)
Rated temperature range: 0-40 deg C
Ingress protection: IP65
NOTE:
When using the Easyush Direct valve from a mains water supply, the pressure may be higher than is
suitable for the design of the bowl which can cause splashing to occur. In such cases t a ow regulator
(supplied) as indicated in Section 5.
Tabla de contenidos
Otros manuales de Producto de plomería de Cistermiser
Manuales populares de Producto de plomería de otras marcas

Weka
Weka 506.2020.00E Instrucciones de funcionamiento

Kohler
Kohler K-6228 Instrucciones de montaje

UBERHAUS DESIGN
UBERHAUS DESIGN 75175017 Manual de usuario

American Standard
American Standard DetectLink 6072121 Manual de usuario

Uponor
Uponor Contec TS Manual de usuario

Pfister
Pfister Selia 49-SL Manual de usuario