Table of Contents
1OVERVIEW 7
2PRODUCT INVENTORY 8
3INTERFACES AND INDICATORS 9
3.1 IRIS 800 9
3.1.1 PCB Unit – Front Panel Indicators 9
3.1.2 PCB Unit – Rear Panel Connectors 9
3.1.3 Cased Unit – Front Panel Indicators 9
3.1.4 Cased Unit – Rear Panel Indicators 9
3.2 IRIS 820 10
3.2.1 PCB Unit – Front Panel Indicators 10
3.2.2 PCB Unit – Rear Panel Connectors 10
3.2.3 Cased Unit – Front Panel Indicators 10
3.2.4 Cased Unit – Rear Panel Connectors 10
3.3 IRIS 840 11
3.4 IRIS 850 12
3.4.1 PCB Unit – Front Panel Indicators and Connector 12
3.4.2 PCB Unit – Rear Panel Connectors 12
3.4.3 PCB Unit – Pin Inputs and Relay Outputs 12
4INSTALLATION – ALARM TRANSMISSION AND POLLING OVER IP 14
4.1 Preparation Prior to Installation 14
4.2 Physical Installation 14
4.3 Checking Network Connection 15
4.4 Polling Configuration 16
4.5 Alarm Transmission Configuration 17
5INSTALLATION – BACKUP TRANSMISSION OVER PSTN OR ISDN 18
5.1 Preparation Prior to Installation 18
5.2 Physical Installation 18
5.3 Checking Network Connection 18
5.4 Alarm Transmission Configuration 18
6INSTALLATION – BACKUP POLLING/TRANSMISSION OVER GPRS 20
Version 1.5 16/10/06 2

6.1 Preparation Prior to Installation 20
6.2 Physical Installation 20
6.3 Checking and Network Connection 20
6.4 Polling Configuration 21
6.5 Alarm Transmission 21
7INSTALLATION – BACKUP TRANSMISSION OVER GSM 22
7.1 Preparation Prior to Installation 22
7.2 Physical Installation and Checking Network Connection 22
7.3 Alarm Transmission 22
8ADVANCED INSTALLATION - DATA CALLS 23
8.1 Installation 23
8.2 Configuration 24
8.2.1 General 24
8.2.2 Calls over ISDN using V.120 Rate Adaption 24
8.2.3 Calls over Ethernet using TCP/IP 24
8.2.4 Calls over GPRS using TCP/IP 25
9ADVANCED INSTALLATION – PIN ALARMS 26
9.1 Installation 26
9.2 Default Alarm Messages 27
9.3 Configuration 27
10 ADVANCED INSTALLATION - SMS MESSAGING 29
10.1 Installation 29
10.2 Configuration 29
11 ALARM PANEL UPLOAD AND DOWNLOAD 31
12 LOCAL CONFIGURATION SOFTWARE 32
12.1 Installation of the Local Configuration Software 32
12.2 Connecting to the Dialler 32
Version 1.5 16/10/06 3

12.3 Running the Configuration Software 32
13 LOCAL CONFIGURATION WITH A TELEPHONE HANDSET 33
13.1 Dialler Default 33
13.2 IP Address 33
14 TROUBLESHOOTING 34
15 SPECIFICATION 35
15.1 Feature comparison 35
15.2 Polling over IP 36
15.3 Alarms over IP 36
15.4 Alarm and Polling Security 36
15.5 Alarm System Upload/Download 36
15.6 Alarm Interface 37
15.7 Ethernet Interface 37
15.8 ISDN Interface 37
15.9 PSTN Interface 37
15.10 GSM/GPRS Interface 38
15.11 SMS Messaging 38
15.12 Data Interface 38
15.13 Pin Inputs 38
15.14 Relay Outputs 38
15.15 LED Status Indicators 40
15.16 Power Supply 40
15.17 Weights 40
16 CONFORMANCE AND SAFETY 41
16.1 Conformance 41
16.2 Conformance to EN50131 and EN50136 41
Version 1.5 16/10/06 4

16.3 Safety 42
Version 1.5 16/10/06 5

Change History
Revision Date Changes
1.5 16/10/08 Added clarifications for EMC conformance
1.4 5/9/06 Added info on time for detection and reporting of alarms
and faults on alarm dialler and pin inputs.
Added details on serial interface data stop/parity/bits.
Changed analogue POTS voltage value to 40V peak.
Removed pin input sense resistors from inventory.
1.3 22/5/06 Requirement to install in suitable enclosure is now
mandatory rather than recommended.
1.2 25/1/06 Added IRIS 840.
1.1 29/12/05 Replace references to Velcro to self-adhesive feet.
Included sense resistors in inventory.
Change references to IRIS Configuration Console to IRIS
Configuration Software.
Added details for pin alarms.
Added product weights to spec section.
0.7 Original production version.
Version 1.5 16/10/06 6

1 Overview
The Chiron IRIS Alarm over IP Dialler range offers a unique way to connect any
standard alarm dialler over an IP network, with backup over traditional PSTN or
ISDN dial-up networks and/or GSM/GPRS wireless networks if required.
An integral polling mechanism is included in all products to provide constant
monitoring of the communications paths so that any problems are reported to the
ARC.
Advanced features such as data calls and SMS messaging are also offered.
The full set of features of each model in the range is included in the Specification
section at the end of this User Guide.
The Installation sections of this Use Guide sets out a straightforward set of
instructions for the installer from the most simple installation for alarm
transmission over an IP network, through installations with communications
backup routes, to more advanced installations which use data call and SMS
messaging features of the IRIS range.
Version 1.5 16/10/06 7

2 Product Inventory
The accessories included with each IRIS unit are as follows:
IRIS
800
(PCB)
IRIS
800
(Cased)
IRIS
820
(PCB)
IRIS
820
(Cased)
IRIS
840
(PCB)
IRIS
850
(PCB)
Main IRIS unit ••••••
Plug top mains power
supply
••
Power cable ••••
Ethernet cable (cream) ••••••
Dialler cable (grey) ••••••
ISDN cable (black) •••
PSTN cable (grey) •••
Installation guide ••••••
18K sense resistor ••••••
Antenna Optional Optional
When using the Local Configuration Software, a standard 9-way modem serial
cable is required for connection of the IRIS Dialler to a lap-top.
For the IRIS 840 and 850, the GSM SIM card can be obtained from the chosen
GSM network operator. Note that a SIM card offering both GSM and GPRS calls
is required to enable the full functionality.
Version 1.5 16/10/06 8

3 Interfaces and Indicators
The interface and indicators on each unit are shown below. Please see the
Installation sections for more details on how these are used.
3.1 IRIS 800
Note – for the IRIS 800 the PCB version is narrower than the cased version.
3.1.1 PCB Unit – Front Panel Indicators
DIAL
ETH
POLL
PWR ETH
3.1.2 PCB Unit – Rear Panel Connectors
DIAL V24
3.1.3 Cased Unit – Front Panel Indicators
Alarm Adapter
IRIS 800
DIAL SDETH POLL RD TR
3.1.4 Cased Unit – Rear Panel Indicators
ETHV24DIALPWR
Version 1.5 16/10/06 9

3.2 IRIS 820
3.2.1 PCB Unit – Front Panel Indicators
PSTN DIAL ETH POLL RD SD TR ISDN
3.2.2 PCB Unit – Rear Panel Connectors
PWR V24 ETH ISDN
PSTN DIAL
3.2.3 Cased Unit – Front Panel Indicators
Alarm Adapter
PSTN
IRIS 820
DIAL SDETH POLL RD TR ISDN
3.2.4 Cased Unit – Rear Panel Connectors
ISDNETHV24DIALPWR PSTN
Version 1.5 16/10/06 10
Este manual sirve para los siguientes modelos
5
Tabla de contenidos
Otros manuales de Sistema de seguridad de Chiron Technology
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario