1.1.1 Video inputs
The SG-1 is capable to process up to one video input. The name of the input is user congurable; by default is Cam 1.
1.1.1.1 Cam 1
Video source can be selected from Network Camera, Encoder or Video port.
PTZ control : The SG-1 is highly integrated with PTZ cameras and provides three control methods, Over IP or via Serial
port and Auto-Tracking Mount.
Video port Select Video source: The SG-1 provides VGA and HDMI input options for video port.
Network Camera
Select IP address: Select from the camera ip address drop list of those available.
Note: A login authentication with the camera might be required. See Media I/O, Network device
manager for more details.
Encoder Select Protocol: The available options are UDP, RTP, RTMP, or RTSP. Enter the primary and
secondary URL/port number.
Serial port
Select this option when the appointed camera uses RS-232 PTZ control protocol. Then
complete the Serial port selection from drop list Port 1~4. See Media I/O, PTZ control port for
more details.
Over IP The option is available when the specied signal type is a network camera. Select this option if
that camera supports networking PTZ control.
Auto-Tracking
Mount
Select IP address: Select from the TP-100 ip address drop list of those available.
Select Tracking mode: off / Auto-Tracking / Auto-Tracking (pan only), the default is the Auto-
Tracking.
Note: A login authentication with the TP-100 might be required. See Media I/O, Network device
manager for more details.