Amano PIX-200 Manual de usuario

PIX-200
Time Signal Option
Distributor's
Installation and Operation Manual

Proprietary Notice
This document contains proprietary information and such information may not
be reproduced in whole or part without the written permission from Amano
Cincinnati, Inc. 140 Harrison Ave., Roseland, New Jersey 07068.
Amano Cincinnati, Inc. reserves the right to make equipment changes and
improvements, which may not be reflected in this document. Portions of this
document may have been updated to include the latest hardware or firmware
version, if applicable.
To ensure safe use of this time recorder/stamp, be sure to thoroughly read this
manual in its entirety before any attempt is made to operate the equipment.
After you have finished reading this manual, be sure to store it and in a safe
place for further reference.
Thank You….
For purchasing another fine product from
Amano Cincinnati, Inc.
Warranty Notice
Any claim for warranty, express or implied, due to the clocks failure to properly
receive the radio signal because of interference, whatever may be the source
of this interference, are hereby expressly excluded.
The PIX-200 has the atomic clock (radio-controlled clock) feature which
displays the current time precisely by automatically receiving time code
signals on long wave radio from the transmitting station. The unit receives the
time code signal via its built-in antenna system.

Distributor's PIX-200 Time Signal Option Installation and Operation Manual i
Table of Contents
Chapter 1: Overview and Installation.........................................................1-1
Specifications (Time Signal Option).................................................1-1
Time Signal Option Installation ........................................................1-2
Materials Required.......................................................................... 1-2
Installing the Time Signal PCB ....................................................... 1-2
Installing The Signal Wires ............................................................. 1-6
External Signal Connections............................................................1-8
Description of Controls For PIX-200 (function buttons) ...................1-8
Chapter 2: Configuring The Time Signal ...................................................2-1
How To Set the Weekly Program (20 steps) ...................................2-1
How To Set the Signal Duration (from 00 to 59 seconds) ...............2-2

ii Distributor's PIX-200 Time Signal Option Installation and Operation Manual
This page intentionally left blank.

Distributor's PIX-200 Time Signal Option Installation and Operation Manual 1-1
Chapter 1: Overview and Installation
This manual is intended to be a reference source for the person(s) responsible
for installing, and configuring the PIX-200 Time Signal Option. Only Amano
Cincinnati, Inc. authorized service personnel and dealers should have access
to this manual.
Before attempting to install and use the Amano PIX-200 Time Signal Option,
please carefully review Chapter 1: Overview and Installation.
This chapter of the manual covers the specifications, accessories, Time Signal
Option installation, external signal connections, and description of controls for
PIX-200.
Specifications (Time Signal Option)
PCB Name: PXR
Contact Output: Dry Contact Output (Normal Open)
Contact Configuration: Single Circuit
Contact Voltage Rating: 30 VAC at 3A or less (resistive), 30 VDC
at 3A or less (resistive)
Program Numbers: 1 – 20 (20 steps)
Duration: 00 – 59 seconds (Default is 5 seconds)
Ambient Temperature: 14°F to 113°F (-10°C to 45°C)
(w/full power reserve battery
Ambient Humidity:
32°F to 104°F (0°C to 40°C)
10% to 90% (non-condensing)
Environment: Indoor use only; dust-free environment.
Keep out of direct sunlight.
Accessories
The following accessories are provided with the Amano PIX-200 Time Signal
Option. After unpacking, please ensure that all of the following items are
provided:
Time Signal PCB
option with
flat cable (1 unit)
This option
manual
(1 copy)
Cable Tie (1)
A & B Seal (2)
• Please note that specifications, appearance, and/or description are
subject to change without notice due to product enhancements.
Time Signal
Option
Manual
A
Seal
B
Seal

1-2 Distributor's PIX-200 Time Signal Option Installation and Operation Manual
• This manual has been carefully prepared, but Amano assumes no liability
for errors and/or omissions. If you should find any errors or unclear
information, please contact your Amano dealer.
Time Signal Option Installation
The following describes a step-by-step procedure for the installation of the
Time Signal Option in a PIX-200. Make sure the power to the PIX-200 clock is
unplugged while you install the PCB Time Signal Option. When the installation
is complete, put the back plate and clock cover on and plug in the power to
verify the regular LCD display is functioning properly.
Materials Required
1. Time Signal PCB with flat cable.
2. Time Signal Option Installation and Operation Manual.
3. Small flathead screwdriver for inserting wires into the time signal terminal
block.
4. Signal sticker for the front panel (B Seal) and program sticker for the top
label (A Seal).
5. Cable tie.
6. The PIX-200 Operation Manual.
Installing the Time Signal PCB
1. Unplug power to the PIX-200 at the outlet.
2. Disconnect the full power reserve battery pack (if installed).
3. Unlock the PIX-200 top cover using the key and remove the cover.
4. Remove the back plate. In case of a wall mount type, remove the back
plate and detach the unit from the wall. See PIX-200 Operation Manual.
5. Disconnect the power plug from the back of the PIX-200 unit.
6. Unscrew the two (2) screws, which are holding the cover in place for the
PCB option cavity and remove the cover (see the following figure – bottom
view).

Distributor's PIX-200 Time Signal Option Installation and Operation Manual 1-3
7. With the cover off, insert the Time Signal PCB ribbon cable through the
slot as illustrated in the following figure - bottom view.
8. Insert the Time Signal PCB (PXR-1) into the cavity in the bottom of the
PIX-200 as illustrated in the following figure – bottom view (the PCB
assembly is notched so the assembly can only be inserted into the cavity
in one direction). Please hold the edge of the PCB to avoid damaging the
PCB.
PCB Option
Cavit
y
Cover
Screws
Slot
Flat Ribbon
Cable

1-4 Distributor's PIX-200 Time Signal Option Installation and Operation Manual
9. The PXR-1 PCB for the Time Signal Option will snap into place under a
tab (see the following figure – bottom view). Use care to push the tab
aside if necessary.
T
Th
he
e
P
PC
CB
B
i
is
s
n
no
ot
tc
ch
he
ed
d
t
to
o
g
go
o
a
ar
ro
ou
un
nd
d
t
th
he
es
se
e
p
po
os
st
ts
s
T
Ta
ab
b

Distributor's PIX-200 Time Signal Option Installation and Operation Manual 1-5
10. Insert the folded ribbon cable through the top slot (see the following figure
- back view). Do not unfold the flat ribbon cable.
11. Insert the folded ribbon cable into the top center ribbon connector (see the
wider cable in the following figure). Be careful not to damage the ribbon
cable during insertion. When fully inserted, the cables' degree of insertion
should be similar as indicated by the white arrows.
13. Be sure the flat ribbon cable also goes under the black plastic arm (see
above figure). Place the option cover back on, and screw in the two (2)
screws to tighten the cover down.
Slots

1-6 Distributor's PIX-200 Time Signal Option Installation and Operation Manual
14. Plug in the power plug, which was disconnected in Step 5. Feed the AC
power cable through one of the holes on the lower portion of the back
plate and attach the back plate until the tab is fully inserted. (Refer to PIX-
200 Operation Manual if the PIX-200 is wall mounted).
15. Reattach the full power battery reserve if that option was installed. (Refer
to PIX-200 Full Power Battery Reserve Instructions).
16. Do not put the PIX-200 cover back on until the configuring time signal
procedure in Chapter 2 is complete. Plug the PIX-200 into a 110/120 AC
power source, and the LCD display window will show the date and time.
Installing The Signal Wires
WARNING: To avoid electric shock, be sure to disconnect the unit
from its power supply. (Both AC power cord and full power reserve
batteries)
1. Unplug power to the PIX-200 at the outlet.
2. Disconnect the full power reserve battery pack (if installed). See Amano
Full Power Reserve System Manual.
3. Unlock the PIX-200 top cover using the key and remove the cover.
4. Remove the back plate. In case of a wall mount type, remove the back
plate and detach the unit from the wall. See PIX-200 Operation Manual.
5. Disconnect the power plug from the back of the PIX-200 unit.
6. Connect the Signal wires into the terminal block and use the cable tie to
secure the wires in place (see the following figures).
!
In order to feed the wires through
the hole of the back plate, secure
the wires using the cable tie as
shown above.
Press the orange protrusion of the
terminal block downwards using a
small flathead screwdriver when
inserting the wires
Otros manuales para PIX-200
1
Tabla de contenidos
Otros manuales de Reloj de tiempo de Amano
Manuales populares de Reloj de tiempo de otras marcas

Easy Clocking
Easy Clocking XENIO 500 Manual

LA CROSSE CLOCK
LA CROSSE CLOCK Harper 404-3450A Manual de usuario

Europa components
Europa components ET167DYD Manual de usuario

TONIN CASA
TONIN CASA Opaca circle Manual de usuario

CS TIMECLOCK
CS TIMECLOCK 2110 Manual de instrucciones

timetac
timetac Evo Smart Manual de usuario