ZoneVu ZVR-510 Manual de usuario

SECURITY with VISION
ZVR-510 RECEIVER
USERS MANUAL

MEYERTECH DIVISION ISSUE 05
Page 2
CONTENTS
1. ZVR-510 WELCOME 4
2. FEATURES 4
3. INSTALLATION 5
3.1 LINK SETTINGS 5
3.2 CONNECTING THE ZVR-510 5
3.3 ADDRESS SETTING 6
4. CONFIGURATION 7
4.1 LOGGING ONTO THE ZVR-510 7
4.1.1 LOGGING ON FROM THE ZVK-007 KEYBOARD 7
4.1.2 LOGGING ON FROM THE ZVK-008 KEYBOARD 7
4.2 KEY TABLES 8
4.2.1 ZVK-007 KEY TABLE 8
4.2.2 ZVK-008 KEY TABLE 8
4.3 HEAD FORMATTING 8
4.4 OSD MENU SYSTEM 9
4.4.1 HEAD FUNCTIONS 9
4.4.2 ALARM FUNCTIONS 11
4.4.3 MEMORY FUNCTIONS 12
4.4.4 DISPLAY FUNCTIONS 13
4.4.5 MISCELLANEOUS FUNCTIONS 13
4.5 LOGGING OFF FROM THE ZVR-510 14
4.5.1 LOGGING OFF FROM A ZVK-007 14
4.5.2 LOGGING OFF FROM ZVK-008 14
5. DIAGNOSTICS 15
5.1 SELF TEST 15
5.2 ON SCREEN DIAGNOSTICS 15

MEYERTECH DIVISION ISSUE 05
Page 3
6. DEFAULT CONFIGURATION 16
7. SPECIFICATIONS 18
7.1 ELECTRICAL 18
7.2 PHYSICAL 18
7.3 FUNCTIONS 18
8. TROUBLE SHOOTING GUIDE 20
9. DECLARATION OF CONFORMITY 21
10. PRODUCT WARRANTY 22
11. APPENDIX A PCB OVERVIEW 23
12. APPENDIX B CONNECTION DIAGRAM 24
13. DOCUMENT HISTORY 25
Whilst every effort has been made to confirm the information in this document is correct,
MEYERTECH DIVISION cannot accept any liability for any errors, omissions and or incorrect
information contained within this document.
No part of this document may be reproduced or distributed in any form or by any means
without prior written consent from MEYERTECH DIVISION.
MEYERTECH DIVISION are committed to continuous product development and therefore
reserve the right to change specifications without notice.
1997 ALL RIGHTS RESERVED.

MEYERTECH DIVISION ISSUE 05
Page 4
1. ZVR-510 WELCOME
Thank you for purchasing the ZoneVu ZVR-510 Telemetry Receiver.
The ZVR-510 fully exploits the benefits of high performance DC variable speed control. The receiver
operates over Coax based MEYERTECH VICTAtelemetry or twisted pair RS422, and is compatible
with the full range of ZoneVu products.
R-510 WELCOME 1 ZVR-
2. FEATURES
♦Variable speed Pan, Tilt Zoom and Focus
♦Simultaneous Pan, Tilt and Zoom
♦Softstop facility
♦Auto/Manual Iris Control
♦PWS (Peak White Suppression)
♦Wash, Wipe and Lamp
♦Latching Auxiliary
♦Momentary Auxiliary
♦Self Test Mode
♦System Diagnostics
♦Programmable Preset
♦Programmable Privacy Zones
♦Programmable Ordered and Random Patrols
♦6 Alarm Inputs + Anti-Tamper and Camera Fail Alarms
♦On Screen Display Configuration
♦COAX/RS422/RS485 Transmission
3INSTALLATION

MEYERTECH DIVISION ISSUE 05
Page 5
3. INSTALLATION
To obtain the optimum performance from your ZVR-510 please take time to read this manual before
commencing installation. If you have any questions or problems our staff will be pleased to assist you
on the technical helplines listed on page 27.
WARNING THIS EQUIPMENT CONTAINS HAZARDOUS VOLTAGES. THIS
EQUIPMENT MUST BE EARTHED TO PREVENT FIRE OR SHOCK
HAZARD. DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR
MOISTURE.
Unpack the ZVR-510 and check the contents against the list below.
♦ZVR-510 PCB
♦Transformer 20V 100VA
3.1 LINK SETTINGS
Links N.O. and N.C. are used to select Alarm contact types. NEVER connect both N.O. and N.C.
N.C. Fit for Normally Closed Contacts.
N.O. Fit for Normally Open Contacts.
LD Fit for ZVR-510
LENS Selects 6 or 12V camera drive level.
422/485 Sets up serial port. (Link out - 422 ; Link in - 485)
422 ( x2 ) Fit for receiving via RS422 and transmitting via VICTA COAX.
Unfitted receives and transmits via VICTA COAX
Note : For Link locations see Appendix A on page 23.
VC1 Variable trimmer capacitor adjusts caption widths of OSD text.
3.2 CONNECTING THE ZVR-510
Connect up the ZVR-510 in accordance with the accompanying wiring diagram, paying special
attention to the maximum ratings and the notes below.
1. The ZVR-510 MUST be Earthed at the AC input supply terminal.
2. NEVER run cables directly under the PCB as this may interfere with the operation of the
Telemetry ZVR-510 and other camera head equipment.
3. ALWAYS use Screened cables for low voltage and signal cables ensuring the screen is
connected to 0V or Earth.

MEYERTECH DIVISION ISSUE 05
Page 6
4. AVOID looming cables of differing characteristics together E.G. Video cables with cables
carrying mains power.
5. If the ZVR-510 is to be operated over twisted pair cable ensure the screen is connected to 0V.
6. If N/O alarms are selected link-out unused inputs to the alarm common.
7. The maximum cable run for Twisted Pair is typically 2Km.
8. The maximum cable run for VICTA is typically 750m.
9. The maximum number of Telemetry Receivers that can be connected to a driver output is 32.
10. The cable used to wire the secondary of the transformer should be a minimum of 0-5mm2.
11. Observe the polarity of the brake wiring. Incorrect connection will result in vibration when
coming out of a mechanical end stop.
To test the ZVR-510 locally press the SELF-TEST switch for approximately 3 seconds. The ZVR-510
will then perform a self test cycle exercising each function in turn. Status LED’s are provided for +12V
and Comms. Received (RXD).
3.3 ADDRESS SETTING
To set the ZVR-510 receiver address:
1. Press and Hold the Self Test Button on the ZVR-510. (See PCB Overview)
2. Apply power to the ZVR-510.
3. When the ZVR-510 powers up, an On Screen Display will display the current receiver address
and give instructions for changing the address.
4. The Self Test button is used to change the receiver address by stepping from left to right
through three numeric fields. These are the Hundreds, Tens and Units which make up the
ZVR-510 network address. A flashing cursor highlights the current field.
5. Momentary key presses increment the value displayed within the current field.
6. A key press of longer than 2 seconds steps to the next field. Either Hundredths to Tens, Tens
to Units or Units back to Hundredths.
7. Ensure that the programmed receiver address is valid.
8. A key press of longer than 5 seconds accepts the displayed address and the ZVR-510
continues to power up as normal.

MEYERTECH DIVISION ISSUE 05
Page 7
4. CONFIGURATION
The ZVR-510 should now be configured by logging onto the receiver from a ZVK-007 keyboard and
following the On Screen Menus.
4.1 LOGGING ONTO THE ZVR-510
4.1.1 LOGGING ON FROM THE ZVK-007 KEYBOARD
Access to Telemetry Receiver Configuration is achieved by logging on to the SUPERVISOR LEVEL
of the keyboard.
1. Log On to the ZVK-007 at Supervisor Level.
2. Use the MODE Key to step through the Menu options to ZVR CONFIG Select using the ENT
key.
3. Use the MODE Key to step through the various receiver options to ZVR-510. Select using the
ENT key.
4. Press the PROG Key to enter the On Screen Display Menu system. ZVK-007 now enters TALK
mode with the ZVR-510 Receiver.
5. The Right Hand Joystick control is used to navigate the OSD Menu System. The current
selected option is indicated by flashing text.
4.1.2 LOGGING ON FROM THE ZVK-008 KEYBOARD
Access to Telemetry Receiver Configuration is achieved by logging on in the following manner.
1. Ensure PTZ mode is off. (Key ‘U’, LED=OFF)
2. Type ∗ZVR#. ZVR-510 enters the On Screen Display Menu system. ZVK-008 now enters
TALK mode with the ZVR-510 Receiver.
3. To navigate the OSD Menu System, select the option by pressing the appropriate upper case
character. The selected option is indicated by flashing text. Confirm by pressing #.
4. After exiting from the ZVR-510 menus type ∗Q to exit TALK mode with the ZVR-510 Receiver.

MEYERTECH DIVISION ISSUE 05
Page 8
4.2 KEY TABLES
4.2.1 ZVK-007 KEY TABLE
The following ZVK-007 keys are used to configure the Receiver.
ENT Proceed to the selected option. Also used to Abort Endstop and Preset
Positioning.
HOLD Used to Save Endstop and Preset positions.
MODE/SHIFT Toggle between Alphabetic and Numeric Keys.
SPACE Toggle between options enclosed within quotes. E.g. [ option ].
DEC Toggles between Upper and Lower Cases when entering Text.
<< Used to delete text characters to the left of the cursor position.
>> Used to delete text characters at and to the right of the cursor position.
4.2.2 ZVK-008 KEY TABLE
The following ZVK-008 keys are used to configure the Receiver.
#Proceed to the selected option.
SUsed to Save Endstop and Preset positions.
XUsed to abort Endstop and Preset positions.
SPACE Toggle between options enclosed within quotes. E.g. [ option ].
DEL Backspace delete.
HOME Press to access joystick control when controlling PTZF.
4.3 HEAD FORMATTING
It is important to configure the following ZVR-510 parameters in the following order before attempting
to configure any other parameters. This is only required if the Pan and Tilt head or lens is fitted with
feedback pots.
1. Feedback Pots (Head Functions Menu).
2. Check joystick control. Make any corrections to joystick control within the PTZF Swap Menu
(Head Functions Menu).
3. Set the End Stops for Pan, Tilt, Zoom and Focus (optional).
4. Set Head Inertia and Drive Level for Slow Speed control to suit the Pan & Tilt Head being used.

MEYERTECH DIVISION ISSUE 05
Page 9
4.4 OSD MENU SYSTEM
Configuration is divided into five sections within the Setup Main Menu of the On Screen Display. To
select a specific category
ZVK-007 navigate the OSD menu using the Right Hand Joystick and select with the ENT key.
ZVK-008 navigate the OSD menu by pressing the character shown as upper case in the option
text. Select with the #key.
Note : Early versions of ZVK-007 (software issues prior to 2-0) should be used to program the ZVR-510 in the
same way as the ZVK-008, with the following exception:
nDo not use the joystick to navigate menu’s. Use upper case letters as per the ZVK-008. If joystick is used
by mistake, press ‘X’ to recover.
4.4.1 HEAD FUNCTIONS
The options within this Menu refer to the camera head. It is important to use the facilities within this
menu to customize the receiver to the type of head the receiver is connected to.
ZVR-510
Setup Main Menu
Head functions
aLarm functions
Memory functions
Display functions
mIsc. functions
Abandon changes
Save change
ZVR-510
Head Functions
Ptzf swap
Feedback pots
Endstops
speed Table
errOr table
Softstop

MEYERTECH DIVISION ISSUE 05
Page 10
PTZF Swap The PTZF SWAP facility is an engineering function to reverse the polarities of
the Pan, Tilt, Zoom and Focus drives. When a receiver is initially installed the
direction of PTZF functions should be checked and reconfigured where
necessary.
Feedback Pots The receiver tests head potentiometers to determine drive feedback and
direction. This also determines whether the head is capable of presets. During
this operation each function (Pan, Tilt, Zoom, Focus) will be exercised by the
receiver as a integrity test. Any faults will be displayed on-screen.
Endstops These can be set for Pan, Tilt, Zoom and Focus. Alternatively, they can be
switched off.
Speed Table Eight head speeds can be programmed corresponding to the eight grades of
sensitivity on the right hand joystick. Using this table, it is possible to set up a
Joystick speed curve. An example is shown below.
Error Table Eight error values can be
programmed corresponding to
the eight speed values set in the
Speed Table. Using this table, it is possible to control the rate that the head
decelerates towards a preset. The value programmed correlates to a distance
away from a target with a head speed. Two example tables are given below.
Head Speed Drive Level
1 1
2 2
3 4
4 7
5 12
6 18
7 24
8 32
Head
Speed
Example Speed Curve
0
5
10
15
20
25
30
35
1 2 3 4 5 6 7 8
Drive Level