Introduction
This document mainly introduces the functional features, installation process and
access methods of ZKIP3 series IPC.

Important Notices
Thanks for selecting our company’s IPC. Before use, please read through the user’s
guide to avoid any unnecessary damage!
All functions depend on the actual product. Since the product is subject to updating,
our company is not responsible for any difference from this guide and not liable for
any dispute over different technical parameters from this guide. The project is
subject to any change without notice.
To learn more, please visit our company’s website www.zkivision.com or local
office.

Table of Contents
I
Table of Contents
1 Overview................................................................................................................ 1
1.1 Product Description..................................................................................... 1
1.2 Product Features.......................................................................................... 1
1.3 Technical Parameters................................................................................... 2
1.4 Product Appearance..................................................................................... 4
1.5 Connecting Terminals.................................................................................. 5
1.6 Basic Procedure........................................................................................... 8
2 Installation and Network Configuration ............................................................ 9
2.1 Hardware Installation................................................................................... 9
2.2 Network Connection.................................................................................. 12
3 Accessing device.................................................................................................. 14
3.1 Using WEB Browser ................................................................................. 14
3.2 Using RTSP Media Player ......................................................................... 15
3.3 Using Mobile Devices ............................................................................... 17
3.4 Using Video Surveillance Software........................................................... 19


Overview
1
1 Overview
1.1 Product Description
The ZKIP3 series products are multifunctional cameras developed for the network
video surveillance system, which feature the standard H.264 compression algorithm
and high-performance single chip SOC to implement the media processing
integration combined with audio/video capture, compression and transmission. The
optimized H.264 coding algorithm guarantees the transmission of sharp and smooth
video effect. The embedded Web Server enables users to conveniently implement
real time surveillance and remote control for front end cameras via browser.
According to different environment, the series products can be configured with
protective covers in various specifications, easily installed and operated, and are
applicable to a variety of occasions for video surveillance systems, as well as to
all-weather and all-environment use.
1.2 Product Features
Hi3512 high-performance multimedia processor, supporting H.264 Main
Profile video coding
Dual code stream, suitable for various networks
Support all kinds of protocols, such as, TCP/IP, HTTP, TCP, UDP, ARP,
SMTP, FTP, DHCP, DNS, DDNS, NTP and UPNP, etc.
Numerous additional functions, e.g. alarm, audio talkback, 485 control, TF
card and reset, etc.
Support Ethernet power supply (PoE 802.3af regulation) (optional)
Support WIFI (802.11b/g/n standard) wireless network module (optional)
Double web indicator lamps for easy judgment of web status

User’s Manual for ZKIP3 Series Standard Box IP Camera V1.7
2
Built-in microphone (or external sound capture devices), used for
implementation of sound capture function
Self-recovery from abnormality and auto reconnection after network
interruption
Automatically capture images during an alarm and send them to the designated
email
Support motion detection and external detector alarm
Allow setting several alarm times and support the remote alarm linkage
Support dynamic IP (DHCP) and dynamic domain name system (DDNS)
Network time synchronization (NTP)
HD cam to support the browsing by 14 users simultaneously, 4 in primary
code stream and 10 in secondary code stream
SD cam to support the browsing by 20 users simultaneously, 10 in primary
code stream and 10 in secondary code stream
1.3 Technical Parameters
Product Name
Standard box IP camera
Product Model ZKIP370 ZKIP350
Cam Properties
Image Sensor 1/3" megapixel progressive
CMOS sensor
1/3.2" two-megapixel
progressive CMOS sensor
Image Resolution
WDR HD
HD
1280×720
Type of Lens
4~9mm manual aperture lens
Day/Night Switch Software conversion, inductive infrared lamp
Minimum Brightness
5 Lux (color)
;
1 Lux (B/W)
Video Coding

Overview
3
Primary Processor Hi3512
Operating System
Embedded Linux
Video Compression
Algorithm H.264 main profile level 3
Audio Compression
Algorithm
G.726/G.711
Video Compression Code
Rate 32~6114 Kbits/s adjustable
Video Resolution Primary Code Stream 1280x720
Secondary Code Stream 320x240
Video Frame Rate 1~25 frames optional
Video
Parameters
WDR HD
Brightness, Saturation, Contrast, Illumination, Sensitivity, Shutter,
Image Up/Down, Image Left/Right, Night Vision Mode, Wide
Dynamic Mode adjustable
HD Brightness, Saturation, Contrast, Image Up/Down, Image Left/Right
adjustable
Terminal funcional
Audio Interface 1 Mic input and 1 linear output (optional)
Alarm Input
1 alarm input (normally opened or normally closed) (optional)
Alarm Output 1 switch output, maximum working voltage: AC 120V/1A, DC
24V/1A
Motion Detection
Allow 4 independent detection areas
Control Interface 1 RS485
Memory Support TF card for video storage and image capture, 32G maximum
(optimal)
Network Interface 10Base-T/100Base-TX Ethernet interface
WiFi 802.11b/g wireless (optional)
Supported Network
Protocols
TCP/IP, HTTP, TCP, ICMP, UDP, ARP, IGMP, SMTP, FTP, DHCP,
DNS, DDNS, NTP, UPNP and RTSP, etc.

User’s Manual for ZKIP3 Series Standard Box IP Camera V1.7
4
Working Environment
Input Power DC 12V, ≥1A
POE Ethernet power supply: comply with 802.3af regulation (optional)
Maximum Power
Consumption
8W
Working Temperature -20~+55 °C
Working Humidity
10%~80%RH
1.4 Product Appearance
Diagram
installation
seat of lens
base
microphone hole
camera
Dimensional drawing(in mm)
Right View

Overview
5
Front view
1.5 Connecting Terminals
STATE
PWR
RESET
AIN AOUT
SDCARD
LAN DC12V
ALARM 485
COM NO INGND
+
-
1. Power Interface( DC 12V ) : Connect to the adapter. This IPC employs the
power supply of DC 12V and no lower than 1A. Do not use any different
power supply as it may damage the camera.
2. Network Interface( LAN ): 10/100M self-adapting Ethernet interface is used
to connect the camera with various network equipments, such as, switch,
router and hub. When it is connected to 10M network, the orange lamp is on.
When it is connected to 100M network, the green lamp is always on.

User’s Manual for ZKIP3 Series Standard Box IP Camera V1.7
6
This interface can also employ Ethernet power supply (POE, optional) and allow the
transmission of power and data through Ethernet cable.
PoE Swicth Router/
3. Reset Button (RESET) : When the camera fails to function during incorrect
operation or accidental failure (e.g. forget IP address or password), or it is used
in different scenes, press down the button for above 5s after a delay of 30s
from powering on to restore the camera to its factory default. The default
user’s name is “admin”, the default password is “admin” and the default IP
address is “192.168.1.88”.
4. Alarm Interface (COM, NO, IN, GND):Connect to alarm input and alarm
output. When the camera receives an alarm from alarm output or Web motion
detection, this interface can send a signal to alarm output to realize real-time
monitoring and overall protection while triggering a remote alarm. The
specific interfaces are presented in the following figure.
1) The schematic diagram of alarm input connection is as follows:
switch
(IN,GND)
alarm input
terminals alarm
input
device
power supplyof
alarm input device
Schematic Diagram of Alarm Input (Normally Opened) Connection
Otros manuales para ZKIP3 Series
1
Tabla de contenidos
Otros manuales de Cámara de seguridad de zkivision