Zenith HydroTap G4 Manual de usuario

802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 1 of 28
Affix Model Number Label
Here
802253NZ
Zenith HydroTap G4
Installation and Operating Instructions
®
BC Residential

Page 2 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00
Tap Options
The Zenith HydroTap G4 appliance series offers a range of interchangeable taps to suit the customer’s needs
Arc / Cube Tap
Classic Tap
Elite Tap
Arc / Cube Mixer
Classic All-In-One Celsius All-In-One
These taps are directly compatible with the HydroTap G4
Command Centre.
The All-In-One Tap is a stand alone tap that may be used
as an alternative to any of the above combinations.
The Mixer tap range is an additional series of taps that
may be used in conjunction with any one of the taps
shown above, to create 4-in-1 models

802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 3 of 28
HydroTap Specifications
Installation Checklist .................................................................................................................... 4
General Product Features............................................................................................................ 5
Important Safety Instructions ....................................................................................................... 6
Warnings and Regulatory Information.......................................................................................... 7
Major Components and Accessories ........................................................................................... 8
Technical Specification ................................................................................................................ 9
Before Installation and Site Requirements................................................................................... 10
Installation Instructions
STEP 1
- Fit the tap to the benchtop or sink before installing the undersink unit.
(Refer to the Tap installation instruction book 803341NZ)
STEP 2
- Check for adequate ventilation
Section 2 - Ventilation
2.1 - Ventilation for All Models............................................................................................ 11
2.2 - Cupboard Air Ciculation.............................................................................................. 12
STEP 3
- Install the Booster Heater (if required)
Section 3 - Booster Heater Installation
3.1 - Product Description................................................................................................... 14
3.2 - Installation Procedure ............................................................................................... 15
3.3 - To Remove / Install the appliance ............................................................................ 15
3.4 - Braided Hose Connections ....................................................................................... 16
STEP 4
- Install the undersink unit
Section 4 - Undersink Unit Installation
4.1 - External bypass valve............................................................................................... 17
4.2 - Hose and tube fitting................................................................................................. 17
4.3 - Model BC 160/125 and BC 160/175 ......................................................................... 18
4.4 - Model AIO Mains ...................................................................................................... 19
4.5 - Model AIO Vented..................................................................................................... 20
4.6 - Model 4-in-1 Vented.................................................................................................. 21
STEP 5
- Commission the HydroTap
Section 5 - Commissioning
5.1 - Select the Language................................................................................................. 22
5.2 - Filter Flush ................................................................................................................ 22
5.3 - Boiling Calibration..................................................................................................... 23
5.4 - Booster...................................................................................................................... 23
5.5 - Sensor....................................................................................................................... 24
5.6 - Command-Centre Flush............................................................................................ 24
Troubleshooting ........................................................................................................................... 25
End of Life Disposal ..................................................................................................................... 26
Contact Details............................................................................................................................. 28
Index

Page 4 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00
Before Installation:
A. Read the instructions and check if there is adequate space to mount all of the components.
B. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied.
C. Check the mains water pressure is between 150 - 700kPa and 200 - 700kPa when a booster
and /or filter softener is fitted
D. Check the water quality to determine if extra filtration will be required.
NOTE: This product must be fitted to a potable water supply
E. Check the appliance rating plate and ensure correct power is available for the appliance.
F. Check the under counter cupboard supporting the appliance is adequate for the total weight
of the appliance, when full of water.
Before Commissioning:
1. Check the unit has been installed correctly.
2. Check all plumbing fittings have been tightened.
3. Ensure the outlet and vent pipes are positioned to drain correctly.
4. Ensure there is adequate ventilation.
5. Check all tubes from the undersink unit to the tap, have a constant rise and there are no
sags or kinks in the hoses.
6. Check all electrical connections are correct and there are no loose wires.
Commission: (see section 5)
7. Flush the supply line before connecting.
8. Turn on the water and check for leaks.
9. Flush the filter(s).
10. Where applicable, program the unit to suit the customer’s requirements.
Installation Checklist

802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 5 of 28
Thank you for purchasing a Zenith HydroTap. Please read and follow these instructions carefully to ensure
safe and trouble free service. If service is required, please call 1800 460 222.
What is the Zenith HydroTap ?
The Zenith HydroTaps are electronically controlled, filtered, Boiling water and Chilled water drinking systems
for kitchens and tea rooms. The HydroTap units are under bench drinking water appliances with a dispensing
tap mounted on a sink or bench, which has been designed for residential applications. These units utilise a
conventional refrigerant compressor to chill the water and an immersion heating element to boil the water.
These units dispense boiling water (factory set to 98°C) and chilled water (factory set to 6-10°C). These units
are NOT designed to be used for sanitary fixtures.
The Boiling water units are fitted with a tap mounted, child safety lock. In addition, there are various energy
saving options accessible via the main menu. Each unit is equipped with a self-calibrating program which
caters for altitude adjustment. The water filter is a disposable item which will require periodic replacement and
is covered by a limited OEM warranty.
It is important that the Installation be done safely, correctly and completely, in order to utilise all the benefits
the HydroTap can provide. The Classic and All-In-One taps may be ordered with the Tap Head Assembly for
Disabled use. The disabled levers are supplied with Braille caps for the visually impaired.
General Product Features
Usage:
The Zenith HydroTap is intended for use in residential household and similar applications such as, rural and
urban residential Kitchens, Hotels, Motels, Bed and Breakfast and other residential type environments.
ON-OFF Switch
Command centre
Din plug
(for accessories)
IEC Socket

Page 6 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00
Important Safety Instructions
This manual contains important safety and installation instructions for the Zenith HydroTap G4.
Safety
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Refrigerant
The Zenith HydroTap unit contains R134A refrigerant under pressure. Maintenance of the refrigeration unit
must be carried out by an accredited service provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all
Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power
outlet must be in a safe visible position for connection.
Venting
Sometimes steam and / or condensed droplets may discharge through a vent outlet at the tap. If the tap is not
installed using the Font pedestal, ensure the tap body is located so the tap outlet safely dispenses into the
sink bowl area.
Lifting
Take care when lifting the Zenith HydroTap unit. Some units may exceed safe lifting limits. If you feel this is
beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked
on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to
section 1.2 technical specification for the weight of your product.
Airflow
The ambient operating temperatures, when installed in a cupboard, must be between 5ºC - 35ºC. The
system will operate satisfactorily only if the recommended air gaps of 50 mm on each side are provided. If a
vent kit is supplied it must be fitted. See section 2 for correct installation details.
Altitude
Water boils at varying temperatures at different altitudes. Your HydroTap adjusts for this during startup
calibration and will recalibrate itself on a regular basis.
Frost Protection
If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not
in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the
connecting pipework and fittings.the elements of nature. This unit must not be positioned i

802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 7 of 28
Important Safety Instructions
Positioning
It is important to ensure the undersink unit is positioned in an accessible area close to the floor level. The
unit must have its base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be
located above the undersink unit.
WARNINGS
1. The Zenith HydroTap unit must be earthed. The resistance of the earth
connection from each exposed metal part must be less than 1 ohm.
2. All Installation and service work must be completed by trained and
suitably qualified Tradespeople. Faulty operation due to unqualified
persons working on this product, or any other Zenith product may void
warranty coverage.
3. All Plumbing must comply with AS/NZS3500.
4. All Electrical must comply with AS/NZS3000
5. All Plumbing and Electrical connections must be made in accordance with
local regulations.
6. This HydroTap product is rated for 230V 50Hz AC operation.
7. Undersink units must never be located near, or cleaned with water jets.
8. Zenith HydroTaps are not to be exposed to the elements of nature
9. Due to the process of continuous improvement, Zenith Water reserves
the right to change details mentioned in this manual, without notice.

Page 8 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00
Accessories Description
HydroTap Booster
Water System with
connection hoses
Font Kit for
Arc & Cube Models
Font Kit for Classic &
Elite Models
Replacement Filter
Disabled Lever Kit
4-In-1 Upgrade Kit
Major Components and Accessories
Parts supplied Description
1 x Tap
option with hoses
(Classic Tap shown)
1 x HydroTap
Undersink Unit with
air and water filters
1 x Mains water
connection hose
1 x Connector +
Strainer Sub-assy
Vent Kit
1 x Inlet vent
1 x Outlet vent
9 x Screws
1 off
HydroTap Booster
Heater & hoses
(supplied with
BCHAV & 4-IN-1
models)
1 x Flow Restrictor
and Tee piece for
Mixer taps and select
models
1 x Mixer Tap
for 4-In-1 and select
models (with hoses)
(Arc tap shown)
1 x Installation
Instructions
(this book) and
1 x User Guide
Install
Instruct
User
Guide

802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 9 of 28
Power
outlets
required
Power
Rating
(kW)
Boost
Rating
(kW)
Unit Dimensions
W x D x H (mm)
with air duct
**Dry
Weight
(kg)
Boiling Chilled
BC 1x10A 1.55 N/A 280 x 470 x 335 24
4 in 1
BCHA 2x10A 1.55 2.2 280 x 470 x 335 24
All in One
BCHA-A 1x10A 1.55 N/A 280 x 470 x 335 24
BCHA-AV 2x10A 1.55 2.2 280 x 470 x 335 24
Technical Specifications
** Add an extra 5 kg when full of water
Models
BC Boiling and Chilled
BCHA 4 in 1
AAll in One - Mains
AV All in One - Vented
DDisabled lever controls (optional accessory)
Before Installation
Before installing ensure that the following have been provided at the Installation
site:
•
Review all the technical specifications.
• Ensure the underbench can support the product weight when full of water (allow an extra 5 kg when full)
•
Sufficient space in the cupboard to install all of the undersink units in accordance with these Installation
Instructions. Refer to technical specification for dimensions. Make allowance for a booster heater and /
or water softener if required. Refer to section 3 & 4 for installation instructions.
•
For BC HydroTaps & BCHA-A (Mains) models, a 220-240V, 10A AC power outlet will be required. For
BCHA 4-In-1 & BCHA-AV (Vented) models, two 220-240V, 10A AC power outlets will be required (one
power outlet for the HydroTap and the other for the Booster heater).

Page 10 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00
Before Installation
Note: Check all cable and hose lengths against inlet /outlet positions before proceeding
(See section 4 for general layout).
•
A potable water supply connection with isolating valve inside the cupboard within reach of the braided
hoses and positioned so that the connection point and the stop cock will not be obstructed when the
undersink units are installed.
•
For the mains pressure All-in-One, an external hot and cold water supply will be required.
•
If an external filtration or water softening device is required, then it is important to allow extra space
for these items.
•
A cold water supply with a minimum working pressure of 150kPa (200kPa when a booster and /or
filter softener is fitted) and a maximum working pressure of 700kPa connected via an isolation valve.
•
The appliance must be placed with its base in a horizontal position.
IMPORTANT!
Do not proceed with the installation if these requirements are not met.
Special Tools Required:
In addition to normal tools, the following will be required:
For the standard and Mixer taps:
•
35mm diameter sheet metal hole punch for sink tops (not supplied)
•
35mm diameter hole saw for timber bench tops (not supplied)
•
Nut runner tube spanner (supplied) for fixing tap assembly.
For the All-In-One tap:
•
50mm diameter sheet metal hole punch for sink tops (not supplied)
•
50mm diameter hole saw for timber bench tops (not supplied)
•
Nut runner tube spanner (supplied) for fixing tap assembly.
Section 1
Tap Installation
Refer to the Tap installation instruction book 803341NZ.
Otros manuales para HydroTap G4
6
Tabla de contenidos
Otros manuales de Sistema de agua de Zenith
Manuales populares de Sistema de agua de otras marcas

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manual de usuario

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manual de usuario

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manual de usuario

Microline
Microline T.F.C.-4 Manual

Eureka Forbes
Eureka Forbes Aquaguard Select Manual de usuario

Cetetherm
Cetetherm AquaEfficiency Manual de usuario