Zenith HydroTap G5 Manual de instrucciones

Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
1
Quick Start Installation Guide
Command Centre
Boiling, Boiling / Ambient models
AFFIX PRODUCT LABEL HERE
Zenith
HydroTap G5
Visit our website to
download the manuals

2Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
Table of contents
SECTION 1: Using these instructions ..................................................................3
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS............................................. 4
SECTION 3: WARNINGS & REGULATORY INFORMATION.................................. 6
SECTION 4: Technical data................................................................................ 8
SECTION 5: Parts supplied................................................................................. 9
SECTION 6: Set up the ventilation ...................................................................10
SECTION 7: Connect the water supply ............................................................. 12
SECTION 8: Set the bypass & install the Limescale filter .................................. 13
SECTION 9: Fit the Booster............................................................................... 14
SECTION 10: Connect the Booster ................................................................... 15
SECTION 11: Connect the Command Centre.................................................... 16
SECTION 12: Commissioning............................................................................ 19

Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
3
SECTION 1: Using these instructions
This document is a Quick Start Installation Guide.
For further details on installing and operating your HydroTap,
download & read the Command Centre installation and user
instructions, which can be found online at:
zenithwater.co.nz
!
Read and use the instructions supplied with individual kit
components for a safe installation.
Before you start
!
!
Explanation of symbols
Read the
instructions
WARNING
!
!
Danger of
electric shock
!
!
Hot surface

4Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
Safety
This appliance is not intended for use by children under 8 years or persons
(including children under 8 years) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by
a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Qualifications
To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cable and power outlet must be
in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water droplets may discharge through a
vent outlet on the tap. If not using the font, ensure the tap body is located
so the tap outlet safely dispenses into the sink bowl.
Lifting
Take care when lifting. The Command Centre may exceed safe lifting
limits. If you feel this is beyond your personal capabilities, please seek
assistance with the lift. The weight of the Command Centre is marked on
the packaging. Do not lift the Command Centre by the front cover or any of
its connections.
!
!
Compliance
In NZ/Australia electrical installation must comply with AS/NZS3000.
In NZ/Australia plumbing installation must comply with AS/NZS3500.
In the UK the system must be installed in accordance with water supply byelaws,
current IEE regulations and local authority byelaws.

Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
5
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
Airflow
The Zenith HydroTap operates within the ambient temperature range 5ºC
- 35ºC. Proper air circulation must be provided. The system will operate
satisfactorily only if the recommended air gaps are provided. The vent kit
supplied must be fitted.
Altitude
Water boils at varying temperatures at different altitudes. The HydroTap
adjusts for this during startup calibration and will recalibrate itself on a
regular basis.
Frost protection
If the HydroTap is located where the ambient air temperature could fall
below 5ºC when the system is not in use, do not turn off the Command
Centre electrically. This safeguard does not offer the same protection to
the connecting pipework and fittings.

6Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
• The Zenith HydroTap must be earthed. The resistance of the earth
connection from each exposed metal part must be less than 1Ω . Use the
power cable supplied. It is the responsibility of the installer to ensure
the power point is earthed.
• All installation and service work must be completed by trained and
suitably qualified tradespeople. Faulty operation due to unqualified
persons working on this product, may void warranty coverage.
• As the installer, it is your responsibility to supply and install all valves as
required by local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
• Connect only to a potable (wholesome, cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the Zenith HydroTap to the elements of nature.
SECTION 3: WARNINGS & REGULATORY INFORMATION
• The booster complies with protection class IP 20.
• For UK, a pressure limiting valve must be fitted for mains water
pressures above the maximum limits stated.
• Use of tools can be hazardous. Assess the risks before you start.
• A clearance envelope around all Command Centres must be provided
to allow adequate ventilation for the safe and effective use of the
HydroTap system.
!
!
• For continued safety of this appliance it must be installed,
operated and maintained in accordance with the
manufacturer’s instructions.
• This appliance may deliver water at high temperature. Refer
to the Plumbing Code of Australia (PCA), local requirements
and installation instructions to determine if additional
delivery temperature control is required.

Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
7
SECTION 3: WARNINGS & REGULATORY INFORMATION
• Valve and fitting threads must be sealed appropriately with PTFE tape
where compression seals are not provided.
• Always flush new filter before use.
• Do not connect Booster to electrical supply until commissioning.
• Do not over tighten plumbing and hose connections.
• Braided hoses supplied cannot be lengthened.
• The power cord and general power outlet must be in a safe and accessible
position after installation. When positioning the appliance, ensure the power
supply cord is not trapped or damaged. If the power supply cord is damaged
it must be replaced by a Zenith service provider or a qualified electrician.
• Do not locate multiple portable socket-outlets or portable power
supplies at the rear of the appliance.
• For safe operation, the HydroTap is designed to be installed,
commissioned and used within 48 hours. Should the HydroTap not be
required for an extended period of time (72 hours or more), do not fill
and commission the HydroTap until ready for first use.
• For water taste and quality reasons, following any non-use period of
more than 72 hours, Zenith recommends to perform a system flush.
Failure to flush the system may affect water quality.
• For UK, this appliance incorporates adequate backflow prevention
in accordance to S.I.1999 No.1148 The Water Supply (Water fittings)
Regulations 1999 Schedule 2 requirement. No further backflow
prevention is required for connection to the water supply.
• For UK, this appliance only contains materials that conform to the
requirements of BS6920:2014 ‘Suitability of non metallic materials and
products for use in contact with water intended for human consumption
with regard to their effect on the quality of water’.

8Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations.
Note: All models (excluding UK) have an internal pressure limiting device
to reduce the maximum mains regulated pressure (700kPa in NZ/Australia),
protecting the system against pressure surges above 500kPa.
!
Water supply connection
1/2” BSP (G1/2)
Booster specification
Specification Rating
Nominal power 2.2kW
Nominal current 10A
Flow rate 1.2 L/m
Water supply pressure requirements
Component Power rating
kW
Dimensions
W x D x H (mm)
Weight
(kg)
B100, BA100 1.8 + 2.2* 280 x 313 x 333 13
B60, BA60 1.8 280 x 313 x 335 13
B, BA Home 1.35 280 x 313 x 335 13
* power rating of the booster
Component Min - Max pressure, kPA (bar)
NZ/Australia
HydroTap 170 (1.7) - 700 (7.0)
Vented Mixer Tap 300 (3.0) - 700 (7.0)
Booster 200 (2.0) - 700 (7.0)
Limescale filter 200 (2.0) - 700 (7.0)
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
Without booster With booster
1x 220 - 240V AC 10A socket 2x 220 - 240V AC 10A sockets
SECTION 4: Technical data

Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
9
SECTION 5: Parts supplied
Parts supplied with the HydroTap For Work For Home
Tap
HydroTap tap kit
Separate Mains mixer Tap kit Optional Optional
Command Centre
Command Centre
Mains electrical supply cable
Water supply inlet hose
Water supply inlet adaptor and strainer
Ventilation kit
Water block kit (UK only) (UK only)
Booster
Booster & hoses Optional
Filters
Water filter & instructions
Limescale filter kit Optional Optional
Font
Font kit Optional Optional
Note: Mains water isolation valve is not supplied with the kit.
Contact Zenith for the full range of consumables and accessories.

10 Quick Start Installation Guide
806836NZ v1.00 01.21 G5 B BA Quick Start Guide
SECTION 6: Set up the ventilation
Command Centre width
!
A clearance envelope around all Command Centres must be
provided to allow ventilation for the safe and effective use of the
HydroTap system.
200mm
50mm 50mm