Z-Wave ZXT-600 Manual de usuario

ZXT-600
AC MASTER
INSTALLATION GUIDE


1
Table of Contents
Introduction..........................................................................................2
Product Overview.................................................................................3
Key Descriptions......................................................................................................... 3
Features..................................................................................................................... 4
Z-Wave Glossary........................................................................................................ 4
Get Started ............................................................................................6
Step 1 Apply Power to ZXT-600.................................................................................. 6
Step 2 Include ZXT-600 to a Z-Wave Gateway ............................................................ 6
Step 3 Setup Automatic Status Report Association to Gateway .................................. 7
Step 4 Setup Air Conditioner IR code .......................................................................... 7
Other Setup Options through Configuration ..................................14
Support for Association Groups .................................................................................. 17
Reset to Factory Default......................................................................18
Mounting ..............................................................................................18
Required tools and supplies........................................................................................ 18
CAUTION .................................................................................................................... 18
Mounting Location Tips.............................................................................................. 19
Mounting the ZXT-600 ............................................................................................... 19
Technical Specifications ......................................................................20
WARRANTY............................................................................................21
Regulatory information.......................................................................22
IC Notice.................................................................................................23
Warnings................................................................................................23
Caution...................................................................................................23

2
Introduction
ZXT-600, AC Master, is a Z-Wave plus compliant Z-Wave-to-IR Bridge
to control split air conditioner by receiving Z-Wave command and
translating to Infrared command. With its comprehensive built-In
and cloud-stored IR database (library). ZXT-600 can control dierent
brands and models of air conditioners worldwide.
ZXT-600 is a security enabled Z-Wave plus device. A security Enabled
Z-Wave Plus Controller must be used in order to fully utilize the
product.
ZXT-600 is a Z-Wave slave device, it depends on gateway to setup
particular AC brand with correct IR code. Dierent gateway has dif-
ferent user interface for setup.

3
Product Overview
Key Descriptions
Micro USB
External IR Port
"PROG" Button LED Indicator
Temperature Sensor
QR CODE
BACK LABEL

4
Features
Z-Wave Glossary
• Working as a Z-Wave thermostat
• Support classic inclusion and NWI
• Built-in air conditioner IR codes, as well as cloud-based IR code
library
• IR learning back up
• Built-in temperature sensor for room temperature report
• Working on battery (2x AA batteries) or USB power
Device or Node Devices and nodes are all terms to describe an indi-
vidual Z-Wave device. These are all interchangeable
when setting up your Z-Wave network.
Inclusion Add a Z-Wave device to the network.
Exclusion Remove a Z-Wave device from the network.
Remove To take a device out of a group, scene or association
group while that device still exists in the same Z-Wave
network.
Network Wide
Inclusion (NWI)
Network Wide Inclusion (NWI) enables both end-user
friendly, Plug and Play like Z-Wave network instal-
lation as well as professional installation scenario
where the inclusion process, in terms of time will be
reduced signicantly. NWI is a feature supported by
a new frame type named Explorer which enables the
Z-Wave protocol to implement Adaptive Source Rout-
ing.

5
Z-Wave Network A collection of Z-Wave devices is controlled by prima-
ry and secondary controllers operating on the same
system. A Z-Wave network has its own unique ID code
so that controllers not in the network cannot control
the system.
Primary Controller The rst controller is used to set up your devices and
network. Only the Primary Controller can be used to
include or remove devices from a network. It is rec-
ommended that you mark the primary controller for
each network for ease in modifying your network.
FLiRS Mode FLiRS is abbreviation for "Frequently Listening Rout-
ing Slave".
FLiRS mode is targeted for battery operated applica-
tions and will enter sleep mode frequently in order
to conserve battery consumption. The response to
Z-Wave command is not as quick as Always Listening
Device. Normally there is 1-2 seconds latency.
Always
Listening Mode
Always Listening Mode is targeted for AC power op-
erated applications and it can act as a repeater, which
will re-transmit the RF signal to ensure that the signal
is received by its intended destination by routing
the signal around obstacle and radio dead spots. The
response to Z-Wave command is immediate.
Association Association is used to organize nodes in different
groups allowing the device to identify the nodes by
a group identier. The groups can also be copied to
other devices.

6
Get Started
• Open the box
• ZXT-600 AC Master x 1pc
Step 1 Apply Power to ZXT-600
• 2x AA batteries or micro USB
• ZXT-600 will detect the rst applied power source to decide what
Z-Wave device role it will be in after included into the Z-Wave
gateway: battery= sleeping device (FLiRS mode). USB power =
always awake device (Always Listening mode), refer to Z-Wave
Glossary for more information.
• Once the ZXT-600 is included into a Z-Wave network, the working
mode (sleeping or awake) cannot be changed, unless it is exclud-
ed and re-apply the power.
• ZXT-600 can be included and operated in any Z-Wave network
with other Z-Wave certified devices from other manufacturers
and/or other applications. All non-battery operated nodes within
the network will act as repeaters regardless of Vendor to increase
reliability of the network.
Step 2 Include ZXT-600 to a Z-Wave Gateway
Step Procedure / Description Status Indicator
1
Refer to your primary controller to enter
into the Inclusion Mode or Exclusion
Mode
2
When it is prompted to enter it, please
triple click the “PROG” button within 1
second.
Green Indicator ashes
TWICE then stay o

7
Notes:
1. It is recommended to perform the Remove (Exclude) procedure before per-
forming an Add (Include) procedure.
2. Red Indicator ashes TWICE then stay off to represent the Add / Remove pro-
cess failed, please repeat the above step again.
3. If the Add (Include) process fails, try Remove (Exclude) and /or resetting the
AC Master to Factory Default and repeat the above step.
Step 3 Setup Automatic Status Report Association to Gateway
Step 4 Setup Air Conditioner IR code
• The UI of set up the IR code varies from dierent gateways. If gate-
ways have dedicated UI for the IR code setup please refer to the
gateway UI and ignore the below steps.
• If your gateway does not have dedicated UI for ZXT-600 IR code
setup, but support Z-Wave thermostat Command Class and Con-
guration Command Class. You may refer to below steps to setup
the IR code using the conguration options in your gateway
Please consult your Gateway suppiler for more detail. Normally, User
can ignore this step during the setup.
ZXT-600 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate with the
primary controller (Gateway/Hub/Controller) for AC Master Status
change report, refer to below for report details:
• Current Room Temperature (report in precision of 0.5°C or 1°F) (It
will be according to Conguration Parameter 39 setting to decide
the trigger level)
• Current Battery Level (Only apply in Low Battery Warning hap-
pened)
• Device Reset Locally Notication (Only report when the AC Master
has been triggered the RESET TO DEFAULT)

8
Step Procedure / Description Status Indicator
1
Refer to your primary controller user
manual, enter to the browser page that
can input the Conguration parameter.
2
Input parameter number “27” and param-
eter value (Please use QR Code scanner to
scan the QR code label (refer to product
overview page), then it will reach to our
Code Finder Webpage to obtain the Code
Number). Then complete the Configura-
tion process.
Green Indicator will
turn on. If fail, Red Indi-
cator will ash TWICE.
3
Go back to the control page of AC Master
on the gateway’s Browser and try the
function such as (Cool, Temperature Set).
If the Air Conditioner does not respond
to the command you set on the Gate-
way (Cool, Heat, Auto, Temperature Set,
etc….), repeat Step 2 and 3 to Select the
next IR Code on the search list.
Green Indicator ashes
ONCE every time if
receives a command
from Gateway
Important Information
• Dierent brand or model of air conditioner has dierent function.
For example, some air conditioner only support temperature set
from 18°C - 30°C, if user set 17°C on gateway, AC Master will not
respond.
• There are more than 1 code for each brand, some does not
support Heat, if User selected a code that does not support
Heat but Original air conditioner supports Heat Function, please
continue to try next code until the correct one is selected.
• You can record down your Device Code for future reference after
setting up the AC Master correctly.
AC Device programmed to your AC Master
Code Number :
Tabla de contenidos
Otros manuales de Controladores de Z-Wave