X-Digital System X-Digital Systems XDS Manual de usuario

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 1 of 11
X-Digital Systems XDS receiver
QUICK START GUIDE
REVIEW THIS GUIDE IN ITS ENTIRET BEFORE INSTALLING
OUR XDS RECEIVER. ALSO, FOLLOW THESE INSTRUCTIONS
BEFORE CALLING SUPPORT.
•Make all satellite RF, data (LAN/WAN) and audio connections
prior to applying AC power to the XDS receiver.
•Westwood One strongly recommends the use of a Phase Locked
Loop (PLL) LNB for your new XDS receiver. The Local Oscillator
(LO) stability of your LNB should not be above (worse than)
25kHz.
•If this XDS receiver is designated to supply DC power to the
LNB at your dish, be sure to turn on the LNB voltage on the
front panel menu AFTER the LNB is connected (See Satellite RF
Connection section 1.1 on page 2).
•Westwood One urges stations to use an Uninterruptible Power
Supply (UPS) for the XDS receiver for equipment protection
from power spikes or brownouts. Also consider lightning
protection if you are located in an area susceptible to frequent
lightning storms. Surge suppressors do not provide sufficient
protection.
NOTE: Appendix A contains a front panel menu map that can help
navigate through the XDS receiver settings and configuration.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 2 of 11
1. MAKING THE CONNECTIONS
Satellite RF, data (LAN/WAN) and audio must be properly
connected. Please follow the steps below:
1.1 SATELLITE RF CONNECTION
Your XDS receiver is pre-tuned to the Westwood One carrier on AMC-8. Once the
satellite RF is properl connected and ou appl AC power, the XDS receiver should
automaticall tune and lock to the Westwood One carrier.
A. Connect the satellite RF to your downlink
Your new XDS receiver is delivered with a parts kit that includes two 6-foot RG-6
cables and an L-band splitter that allows DC power to pass through one port.
B. Verify the XDS receiver is tuned and locked to the WESTWOOD ONE
carrier
Once the satellite RF is properl connected, appl AC power to the receiver and
verif as follows:
•If the SIGNAL LED is green then the receiver is locked to the WESTWOOD
ONE carrier and the LCD screen will displa :
(Cumulus Media / WWO Networks logo)
EB ##.# AG ### (# = numerical value)
EB should be above 7 and AG should be between about 40 and 60 for
proper operation.
•If the XDS receiver does not acquire the Westwood One carrier, the red
FAULT LED will illuminate steadil and the LCD screen will displa :
(Cumulus Media / WWO Networks logo)
EB __._ AG ### (# = numerical value)
Verif proper RF connections and the XDS receiver should automaticall
lock to the carrier.
To manuall tune the XDS receiver to Westwood One carrier on AMC-8:

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 3 of 11
oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrow ke s to reach Setup. Press SET.
oPress the left or right arrow ke s to reach Tuner. Press SET.
oPress the left or right arrow ke s to reach Frequency. Press SET.
oUse the four arrow ke s and the SET ke to set the frequenc to
01000500 kHz
oPress the left or right arrow ke s to reach Symbol Rate. Press SET. Use
the four arrow ke s and the SET ke to set the s mbol rate to
09259574 sps
The XDSPRO receiver should lock. (Green SIGNAL LED will illuminate
steadil ).
If this XDS receiver is designated to suppl DC power to the LNB at our dish, ou
can turn on the LNB voltage on the XDS receiver front panel menu as follows:
•Make sure our downlink LNB is connected to the XDS receiver
•Appl AC power to the receiver
oFrom the main screen with the Cumulus Media Networks logo, press the SET
ke , then press the left or right arrows to reach Setup. Press SET.
oPress the left or right arrows to reach Tuner. Press SET.
oPress the left or right arrows to reach LNBV, Press SET and turn the LNB
Voltage on.
If the front panel of your XDS receiver displays flashing red
lights, this indicates all Activation and Installation steps have
not been completed and/or your XDS receiver is not connected
to the internet. All Activation and Installation steps, including
your internet connection, must be completed or you will NOT
receive Westwood One programming. our XDS receiver must
ALWA S be connected to the internet 24/7/365.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 4 of 11
1.2 AUDIO OUTPUT CONNECTIONS
Once the XDS receiver is locked to the Westwood One carrier ou can verif audio
functionalit as follows:
A. Verify audio reception
Initiall the XDS receiver headphone output and all the audio ports are programmed to
receive the Test Channel.
Connect a set of headphones and verif ou can hear the Test Channel.
To manuall program the XDS receiver headphone to output the Test Channel:
oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrows to reach Audio Ports. Press SET.
oPress the left or right arrows to reach Headphones. Press SET.
oPress the left or right arrows to reach Program. Press SET.
oUse the up and down arrows to find Test Channel. Press SET.
B. Verify audio ports
Your new XDS receiver is delivered with a parts kit including four mating DB-9
connectors with shells.
The analog audio outputs for our services appear at the four DB-9 connectors on
the rear panel. Wiring pinouts are the same as on the older Starguide receivers:
AUDIO OUTPUT – DB9M
Pin Signal Signal Pin
1
L+ L- 6
2
GND GND 7
3
- - 8
4
GND R- 9
5
R+
Rule: Each DB-9 connector carries one radio program stream, either mono or
stereo. If the program is mono, the same audio appears on the left and right pin
pairs. In most cases, the left and right sides of a stereo channel are no longer
used b Westwood One to carr unrelated mono programs. Other networks and
distributors ma use different rules.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 5 of 11
Your receiver should be pre-configured to output the Test Channel on all ports.
Verif ou can hear the test program through all receiver ports.
To manuall program the XDS receiver to output the Test Channel on a desired audio
port: oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrows to reach Audio Ports. Press SET.
oPress the left or right arrows to select the Audio Port (letter A, B, C or D).
Press SET.
oPress the left or right arrows to select Program. Press SET.
oUse the up and down arrows to find Test Channel. Press SET.
1.3 INTERNET CONNECTION
This new XDS receiver requires connection to an alwa s-on internet pathwa . The
internet pathwa is used b Westwood One to troubleshoot remotel , send audio or
text content to our receiver’s storage, send commercial pla back schedules, retrieve
as-pla ed logs of commercials inserted b the receiver, and more.
Your XDS receiver is delivered with a 20-foot Categor 5 data patch cord wired “straight
through” (not crossover) for connection to our networks hub or switch.
A. Connect the XDS Receiver to your network
If ou elect to place our XDS receiver in our local network “inside” our
firewall, connect our network cable to one of the receiver’s LAN ports. The
receiver is set b default to obtain a d namic IP address, also called a “DHCP
address”, from our network’s DHCP server. If there is no DHCP server or ou
elect to assign a static IP address, ou can do it as follows:
Assigning a Static IP address to a LAN Port:
oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrow ke s to reach Setup. Press SET.
oPress the left or right arrow ke s to reach Network. Press SET.
oThe default settings for DHCP is ON. Use the SET and arrow ke s to change
DHCP from ON to OFF.
oPress the left or right arrow ke s to go to the LAN Address menu. Press SET.
oUse the up and down arrow ke s and the SET ke to set the desired IP
address.
oPress the left or right arrow ke s to go to the LAN Subnet menu. Press SET.
oUse the up and down arrow ke s and the SET ke to set the desired subnet
address.
oPress the left and right arrows to go to the Gatewa menu and press SET.
oUse the up and down arrow ke s and the SET ke to set the desired gatewa
address.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 6 of 11
Assigning a Static IP address to the WAN Port:
If ou elect to connect our receiver in a firewall zone called a “DMZ”
(demilitarized zone) or ‘“Outside” the firewall where it can see the internet
directl , connect our network cable to the receiver’s WAN port. You must
assign a static IP WAN Address, WAN Subnet, and Gateway. Follow the
“Assigning a Static IP address to a LAN Port” instructions above to go to the
appropriate WAN menus and change settings as desired.
NOTE: If our network requires the use of a prox server, please refer to the
online user’s guide located at our affiliate’s website. Refer to Section 2 on page
7 for instructions on how to login to ou our website.
B. Test connection to the Westwood One NOC
oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrow ke s to reach Setup. Press SET.
oPress the left or right arrow ke s to reach Network. Press SET.
oPress the left or right arrow ke s to TEST NOC. Press SET.
oPress the NOC softke to perform the test.
The test will take a minute or two. You will get a SUCCESFULL CONNECTED
TO NOC message if our IP settings are correct. Otherwise ou will get a
CANNOT CONNECT TO NOC message and ou will need to adjust our IP
settings (on the receiver, or in our network’s switches, routers or firewall) until
the receiver can connect to the NOC.
To troubleshoot, ou can use the PING softke to verif our receiver can locall
connect to our network gatewa .
1.4 AUTOMATION RELA CLOSURES
There are two DB-37 connectors on the rear panel which together contain a total of 32
mappable rela (or contact) closures to drive our station automation.
Your XDS receiver is delivered with a parts kit including two mating DB-37 connectors
with shells.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 7 of 11
NOTE: Wiring pinout for the RELAY A port is the same as on the StarGuide receiver
with Westwood One Netcue Card.
The pinouts for the DB-37 connectors are:
RELAY A - DB37M
RELAY B - DB37M
Pin Signal Signal Pin Pin Signal Signal Pin
1
RLY1A RLY1B 20 1
RLY1A RLY1B 20
2
RLY2A RLY2B 21 2
RLY2A RLY2B 21
3
RLY3A RLY3B 22 3
RLY3A RLY3B 22
4
RLY4A RLY4B 23 4
RLY4A RLY4B 23
5
GND GND 24 5
GND GND 24
6
RLY5A RLY5B 25 6
RLY5A RLY5B 25
7
RLY6A RLY6B 26 7
RLY6A RLY6B 26
8
RLY7A RLY7B 27 8
RLY7A RLY7B 27
9
RLY8A RLY8B 28 9
RLY8A RLY8B 28
10
GND RLY9B 29 10
GND RLY9B 29
11
RLY9A RLY10B 30 11
RLY9A RLY10B 30
12
RLY10A RLY11B 31 12
RLY10A RLY11B 31
13
RLY11A RLY12B 32 13
RLY11A RLY12B 32
14
RLY12A GND 33 14
RLY12A GND 33
15
NQ Txd RLY13B 34 15
NC RLY13B 34
16
RLY13A RLY14B 35 16
RLY13A RLY14B 35
17
RLY14A RLY15B 36 17
RLY14A RLY15B 36
18
RLY15A RLY16B 37 18
RLY15A RLY16B 37
19
RLY16A 19
RLY16A
If ou or our automation vendor has developed a program that can read Westwood
One Netcues directl , ou ma get the Netcue serial stream from pins 15 and 10 on the
Relay A port on our XDS receiver (see pinout above). The “NQ TxD” pin is RS-232
data with no flow control or handshaking. Baud rate is set b default to 9600 bps 8N1.
THREE CHARACTER NETCUES:
If ou currentl use a Netcue/Data card in our Starguide receiver, an 3-character
Netcue that Westwood One sends out can be mapped to an contact closure ou wish.
Contact
our Technical Services department or contract Help Desk to help ou map our existing
Netcues to the same rela pins on one of the DB-37 connectors on our new XDS
receiver.
2. VERIF PROGRAMMING AND ACTIVATE
In the XDS s stem each program, not each channel, is permissioned and labeled for
station use. Therefore, instead of tuning to a channel to find a program, ou will

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 8 of 11
schedule the programs to appear on each output port. You will need to review our
schedule and activate our receiver with our stations programming.
Initiall our receiver onl outputs the Test Channel on all ports, the front panel LCD
shows a “Please Activate” message and the orange UPDATE LED in flashing.
You must edit and activate the schedule of the programs that ou want to appear on
each audio output port of the XDS receiver through the WESTWOOD ONE Affiliate
website at
http://m xdsreceiver.cmneng.com
To login ou will use the XDS receiver’s serial number as the username and a password
generated b the receiver. To find this password:
oAt the main screen with the Cumulus Media Networks logo, press the SET
ke , then the left or right arrows to reach Setup. Press SET.
oPress the left or right arrows to select Serial Number.
oPress the PWD softke to displa our password.
Once logged in, ou ma setup a friendl password to the site and also review and
approve our receiver’s setup (Time Zone, Schedule, Rela Mappings, etc).
Adjust Time Zone
Setup the appropriate time zone for our receiver
Review Schedule
You will see the default schedule for ever station our receiver supports. Please modif
and verif our schedule as desired.
RULE: Each call-letter radio station at our site that carries an Westwood One
programming or commercials from this XDS receiver must be assigned to an XDS
receiver port and each port must be scheduled to output the programs ou need.
NOTE: Your new XDS receiver contains about 32 hours of audio storage which ou ma
use to “tape dela ” network programs and schedule them to pla later. You can
schedule the same XDS receiver port to “pla back” a mixed schedule of live and
dela ed programs.

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 9 of 11
Review Relay Mappings
You will see the default rela mapping configuration for our receiver. Please modif
and verif our mappings as desired.
Approve Setup and Activate
Once ou reviewed all our desired settings, check the APPROVE SETUP AND
ACTIVATE box, press the UPDATE button, and the NOC will send the updated
programming to our receiver.
It ma take a couple of minutes for the XDS receiver to download the Westwood One
programming information. To verif our receiver is activated, the UPDATE LED will
turn off and the front panel LCD will displa the “XDSPRO” message instead of the
“Please Activate” message
3. SUPPORT CONTACT INFORMATION
If ou have an problems please call Westwood One Technical Services and the will
help ou set up and verif our receiver.
The Westwood One Technical Services office is staffed Monday to Friday from
9:00 AM to 6:00 PM ET for technical assistance.
Westwood One | Technical Services
100 Manhattanville Road, Suite 11
Purchase, N. . 10577
Phone : (914) 908-3210
Fax : (914) 305-9846
E-MAIL: techservices@westwoodone.com

Revision J 9/30/2014 R830000-1060 Quick Start Guide, XDSPRO Receiver
Page 10 of 11
APPENDIX A – XDS RECEIVER MENU MAP
U/D
L/R
EB AG
XDS PRO4
XDS PRO4
Setup
XDS PRO4
Status
XDS PRO4
Audio Port
L/R
L/R
U/D
Setup
Network
Setup
Serial Number
XDSP-000000
Setup
M&C Ports
115K,8,None,1
Setup
Factory Defaults Setup
Version
Setup
Alarms
0FFBDFFF
Setup
Tuner Setup
Relays
L/R
L/R L/R
L/R L/R
L/R
L/R
L/R
Active Faults
OK Fault History Environment
Temp: 39°C
Fan: HIGH
Power Status
1.2V=1.21
5.0V=5.09
Storage Status
Total: 3884MB
Avail: 3683 MB
U/D
Setup
Frequency Setup
Symbol Rate Setup
FEC Setup
LNB Power
Audio Port #
Station
Audio Port #
Program Audio Port #
Spot Audio Port #
Settings
L/R L/R L/R
L/R
L/R L/R L/RL/R
Audio Port A Audio Port B Audio Port C
Audio Port DHeadphones
L/R
L/R L/R L/R
L/R
U/D
U/D
L/R L/R
L/RL/R
L/R
Setup Network
WAN Subnet
Setup Network
Gateway
Setup Network
Test NOC L/RL/R L/R
Setup Network
LAN Subnet
Setup Network
DHCP Setup Network
LAN Address Setup Network
WAN Address
L/R L/R L/R
L/R
L/R
U/D
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Receptor de X-Digital System

X-Digital System
X-Digital System XDS PRO1 Manual de usuario

X-Digital System
X-Digital System XDS PRO04P Manual de usuario

X-Digital System
X-Digital System XDS PRO4-P Manual de usuario

X-Digital System
X-Digital System PRO4 Manual de usuario

X-Digital System
X-Digital System PRO4 Manual de usuario

X-Digital System
X-Digital System XDS-PRO Manual de usuario

X-Digital System
X-Digital System PRO4 Manual de usuario