Integral flow orifice plate
assembly
F510

1
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
CONTENT
1. General .................................................................................................................................................................... 2
1.1 Introduction .......................................................................................................................................................... 2
1.2 Information regarding the user manual ................................................................................................. 2
1.3 Warranty................................................................................................................................................................. 2
2. Warnings ................................................................................................................................................................ 3
3. Pre-installationinspections ............................................................................................................................ 4
4. Installingandoperatingtheproduct........................................................................................................ 4
4-1. General ................................................................................................................................................................. 4
4-2. Direction of installation................................................................................................................................. 5
4-4. Option ................................................................................................................................................................... 8
4-5. Inspection ............................................................................................................................................................ 8
5. Maintenance......................................................................................................................................................... 9
6. Transport,packagingandstorageoftheproduct ............................................................................. 9

2
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
1. General
1.1Introduction
TheIntegralorificeplatemanufacturedbyWISEControlInc.isinstalledinthemiddleofapipewhere
afluidflows.Theareaoftheorificeplateissmallerthanthepipe,andthepressuredifferential
betweenthefrontandrearoftheorificeplateisusedtomeasureflowrate.
Integralorificeplatesaremanufacturedaccordingtocustomerspecifications.
1.2Informationregardingtheusermanual
1) Theusermanualcontainsimportantinformationforproperhandlingofthedevice.Pleasereadthis
usermanualcarefullybeforeinstallationandcommissioning.
2) Pleaseadheretothesafetyandhandlingguidelinesprovidedinthisusermanual.Compliancemust
bemaintainedwiththeapplicableaccidentpreventionandsafetyregulations,aswellasnational
installationstandardsandacceptedcodesofconduct.
3) Thisusermanualispartoftheproduct,andmustbemadeavailableforviewingbyworkersnearby
theinstallationlocationatalltimes.
4) WISEControlInc.reservestherighttomodifytechnicalelementsoftheproductwithoutprior
notice
1.3Warranty
TheIntegralorificeplatemanufacturedbyWISEControlInc.hasbeenmanufacturedaccordingto
individualcustomerrequirements.Theproductmustbestoredunderappropriateconditions,andthe
requirementsinvariousdocumentation,testreportsandusermanualsmustbeobservedtomaintain
optimalusecondition.

3
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
2. Warnings
Handlingmanualforsafeuse
Toensuresafeandproperuseoftheproduct,pleasethoroughlyreadthishandlingmanualbefore
use.Improperhandlingmaycauseequipmentmalfunction,aswellasaccidentssuchasinjury.
Warnings
1) Forsafety,installationmustbecarriedoutbyworkerswithprofessionalexpertiseininstruments
andelectricalworks.
2) Installtheproductintheuseenvironmentprescribedinthespecifications.
3) Usewithinthegiventemperaturerange.
4) Protectfromexcessiveload,vibrationorimpact.
5) Donotmoveorlifttheorificeplateusingthenameplate.
(Thenameplateisintendedforidentificationonly,andtransportorliftingoftheproductusingthe
nameplatemayresultindamage.)
!

4
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
3. Pre-installationinspections
1) Checkthetagnumberoftheproductandconfirmthattheproductisintendedfortheinstallation
location.
2) Checkforanyweldingbeadsorprojections.Priortoinstallation,checkthesurfaceoftheorifice
plateforanydentingorscratching.
3) Theinsideofthepipemustbesmoothandclean,andfreeofanyforeignmatter.
4. Installingandoperatingtheproduct
4-1.General
DifferentialpressuregeneratedbytheIntegralorificeplateisdischargedthroughconnectionstothe
upstreamanddownstreampressuretaps.Theconnectionsaredesignatedasupstreamand
downstreamtapsbasedonthedirectionofflowofthefluid.
Thedirectionofflowofthefluidisindicatedonthefrontofthenameplateoftheorificeplate.
(See<Figure1>)
< Figure 1 >

5
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
4-2.Directionofinstallation
Theintegralorificeplatemustbeinstalledaccordingtothedirectionofflow.Theinstallationdirections
inthefigurebelowarerecommendeddependingonthetypeoffluid.
1) Installationongas&vaporlines
● Installationinhorizontalpipes ● Installationinverticalpipes

6
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
2) Installationonliquidline
● Horizontalpipeandbottomtap ● Horizontalpipeandsidetap
● Installationinverticalpipes

7
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
3) Installationonsteamline
● Horizontalpipeandbottomtap ● Horizontalpipeandsidetap

8
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
4-4.Option
1) Transmitter
- Model:SMT2001
- Refertothehomepageforthe
SMT2001manual.
(www.wisecontrol.com)
2) Extendedlegset
- Appliedatoveroper.temp.120℃.
- Refertotheright<Figure2>.
4-5.Inspection
1) Checktheinstallationlocationoftheintegralorificeplate,andthedirectionofflow.
2) Checkthattheinnersurfaceofthepipeissmoothandcleaned.
3) Confirmthattheconnectionflangeformsaconcentriccirclewiththeinsideofthepipeline,and
thatthepressuretappointshavebeenalignedinaccordancewiththedrawings.
4) Allweldbeadsmustbeuniform.Ensurethatprojectionsintotheinsideofthepipearekepttoa
minimum.
5) Ensurethatthetapsandrelatedpipesarecleanpriortouse.Inspectthetapholesandrelated
pipesforweldsandotherobstructions.Removeobstructionsasnecessary.
<Figure 2>

9
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
C-QIM-2731-F02_EN_Rev.1
5. Maintenance
1) Dependingonprocessconditions,regularlyinspectforsignsofobstruction,erosionorcorrosion.
2) Priortobeginningwork,confirmthatpipeshavebeenpurgedofpressureanddrained.
3) Observepowerplantsafetyregulationsatalltimes.
4) Aftercomplyingwithsitesafetyregulationsandremovingthefluidflowingthroughthepiping,
loosenallbolts/nutsbeforeworkandtheorificeplatecanbecheckedorreplaced.
5) Whenreassemblingtheproductafterdisassembly,newgasketsmustbeused.
Whenreassembling,payattentiontotheupstreamanddownstreamdirections.
6. Transport,packagingandstorageoftheproduct
1) Theproductmustnotbeexposedtohumidity,dustorothercontaminants.
2) Theproductmustnotbesubjectedtoimpactduringstorage.
3) Whenreturningtheproductforrepairs,safelypackagetheproductinitsoriginalpackaging,and
returntherelateddocumentationaswell.
4) The product should be protected from exposure to humidity, dust and other contaminants
duringtransport.
5) Theproductshouldbepackagedtoprotectagainstimpactduringtransport.
6) Anydamagetotheproductduringtransportshouldberecordedinthedocumentation.Claims
forcompensationfordelaysininstallationmaybemadeagainstthetransportingcompany.
Tabla de contenidos
Idiomas:
Otros manuales de Instrumento de medición de Wise

Wise
Wise P751 Manual de usuario

Wise
Wise T500 Series Manual de usuario

Wise
Wise P620 Series Manual de usuario

Wise
Wise P670 Manual de usuario

Wise
Wise P510 Series Manual de usuario

Wise
Wise P810 Manual de usuario

Wise
Wise P710 Manual de usuario

Wise
Wise F850 Manual de usuario

Wise
Wise SMT3000 Manual de usuario

Wise
Wise P257 Manual de usuario
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario