Page 9
Service Manual - Frozen Beverage Dispenser
Unit Does Not Turn ON
1. Make sure the circuit breaker for the electrical outlet
is not tripped and is turned on.
2. Make sure that the power cord is properly
connected to the electrical outlet.
3. Make sure that the main power switch is on.
Mixture Does Not Freeze
1. Make sure that the refrigeration switch is in the (|)
position.
2. Make sure that the slush mixture is properly diluted.
Proper sugar content is 11 - 20%.
3. Make sure that the clock is set to the current time
and that the timer is set to freeze at the current time.
See "SETTING THE TIMER CLOCK" (CFB2 and
CFB3 only).
4. Make sure that the thickness setting is not set too
low. See "Adjusting Slush Thickness".
5. Make sure that there is sufcient ventilation. The
unit will not function properly if there is not sufcient
air space around the sides and back of the unit,
6. Make sure the lter (CFB2 and CFB3 only) is clean
and that the ventilation grills are not blocked or dirty.
See the "CLEANING" section.
7. Make sure the unit is not close to sources of heat
that could affect proper operation (heaters, cooking
grills, etc.).
8. Check to see if compressor reset switch inside
control panel is "popped out" (CFB2 and CFB3
only). See steps 5, 6 and 7 above for possible
causes of overheating. Push in to reset (see
diagram below) after checking for problems that
could be causing overheating and allow sealed
system to cool before restart. If reset switch
continues to pop out, call for service.
TROUBLESHOOTING
Tap Leaks
1. Make sure that the (red) tap gasket is properly
lubricated and is not worn out.
2. Make sure that the tap handle assembly is properly
seated.
Slush Does Not Come Out of Tap
This problem is usually caused by slush that is too thick
or ice chunks forming in the bowl.
1. Make sure the slush mixture is properly diluted.
Proper sugar content is 11 - 20%.
2. Make sure the slush thickness setting on the back of
unit is not set too high.
Leak at Back of Mixing Bowl
1. Make sure that the mixing bowl is properly seated.
2. Make sure that the mixing bowl seal is properly
lubricated and is not worn out.
Auger Does Not Turn or is Noisy
1. Make sure the mixing switch is turned on.
2. Make sure the slush mixture is properly diluted.
Proper sugar content is 11 - 20%. An improperly
diluted mixture can cause ice chunks that can
interfere with proper auger operation.
3. Make sure the auger seal is properly installed and
lubricated.
High Pressure Light On (front panel)
CFB2 and CFB3 only. Turn off the main power switch
and check the following:
1. Make sure that there is sufcient ventilation. The
unit will not function properly if there is not sufcient
air space around the sides and back of the unit.
2. Make sure that the lter is clean and that the
ventilation grills are not blocked or dirty. See the
"CLEANING" section.
3. Make sure that the unit
is not close to sources
of heat that could
affect proper operation
(heaters, cooking
grills, etc.).
4. If the light continues
to come on during
operation, turn off the
main power switch and call for service.
High pressure
light
Compressor Reset